Oligonucleotide Anion Adduct Formation Using Negative Ion Electrospray Ion-Mobility Mass Spectrometry

被引:12
|
作者
Sutton, J. Michael [1 ]
El Zahar, Noha M. [1 ,2 ,3 ]
Bartlett, Michael G. [1 ]
机构
[1] Univ Georgia, Dept Pharmaceut & Biomed Sci, Coll Pharm, Athens, GA 30602 USA
[2] Ain Shams Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Cairo 11566, Egypt
[3] King Salman Int Univ, Fac Pharm, Med Chem Dept, Ras Sedr 46612, South Sinai Gov, Egypt
关键词
oligonucleotide; ion-mobility mass spectrometry; anion adduction; electrospray ionization; LIQUID-CHROMATOGRAPHY;
D O I
10.1021/jasms.0c00380
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Improving the mobile phase of electrospray oligonucleotides has been a major focus in the field of oligonucleotides. These improved mobile phases should reduce the charge state envelope of oligonucleotides coupled with electrospray ionization, which is key to reducing spectral complexity and increasing sensitivity. Traditional mobile phase compositions with fluorinated alcohol and alkylamine, like hexafluoroisopropanol (HFIP) and triethylamine (TEA), have a large amount of cationic adduction and many charge states. Utilizing different fluorinated alcohol and alkylamine combinations, like nonafluoro-tert-butyl alcohol (NFTB) and octylamine (OA), can selectively reduce the charge states analyzed. Other classes of biomolecules have been analyzed with anionic salts to stabilize complexes, increase the molecular peak detection, and even provide unique structural information about these molecules; however, there have been no studies using anionic salts with oligonucleotides. Our experiments systematically study the stability and binding of ammonium anionic salt. We show that anions selectively bind low charge states of these oligonudeotides. Ionmobility measurements are made to determine the collision cross section (CCS) of these oligonucleotides with anion adduction. We utilize both a nucleic acid exact hard sphere simulation (EHSS) calibration and a protein calibration. We are able to show that NFTB/OA is a good choice for the study of oligonucleotides with reduced charge states for the binding of anionic salts and the determination of CCS using ion mobility.
引用
收藏
页码:497 / 508
页数:12
相关论文
共 50 条
  • [2] Mechanical ion gate for electrospray-ionization ion-mobility spectrometry
    Zhou, Li
    Collins, David C.
    Lee, Edgar D.
    Lee, Milton L.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (01) : 189 - 194
  • [3] Mechanical ion gate for electrospray-ionization ion-mobility spectrometry
    Li Zhou
    David C. Collins
    Edgar D. Lee
    Milton L. Lee
    Analytical and Bioanalytical Chemistry, 2007, 388 : 189 - 194
  • [4] Ion-Mobility Mass Spectrometry in Metabolomics and Lipidomics
    Astarita, Giuseppe
    Paglia, Giuseppe
    Yu, Kate
    LC GC EUROPE, 2015, 28 (09) : 520 - +
  • [5] Ion-Mobility Mass Spectrometry in Metabolomics and Lipidomics
    Astarita, Giuseppe
    Paglia, Giuseppe
    Yu, Kate
    LC GC NORTH AMERICA, 2015, 33 (09) : 702 - +
  • [6] Erratum to: Mechanical ion gate for electrospray-ionization ion-mobility spectrometry
    Li Zhou
    David C. Collins
    Edgar D. Lee
    Alan L. Rockwood
    Milton L. Lee
    Analytical and Bioanalytical Chemistry, 2010, 398 : 1833 - 1833
  • [7] Chloride anion attachment in negative ion electrospray ionization mass spectrometry
    Cole, RB
    Zhu, JH
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (07) : 607 - 611
  • [9] NEGATIVE-ION FORMATION IN ELECTROSPRAY MASS-SPECTROMETRY
    STRAUB, RF
    VOYKSNER, RD
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) : 578 - 587
  • [10] Applications of ion-mobility mass spectrometry for lipid analysis
    Giuseppe Paglia
    Michal Kliman
    Emmanuelle Claude
    Scott Geromanos
    Giuseppe Astarita
    Analytical and Bioanalytical Chemistry, 2015, 407 : 4995 - 5007