A novel label-free terbium(iii)-aptamer based aptasensor for ultrasensitive and highly specific detection of acute lymphoma leukemia cells

被引:17
|
作者
Wu, Siwen [1 ]
Yang, Nuo [1 ]
Zhong, Liping [1 ]
Luo, Yiqun [1 ]
Wang, Huiling [1 ]
Gong, Wenlin [1 ]
Zhou, Sufang [1 ]
Li, Yanmei [1 ]
He, Jian [1 ]
Cao, Haopei [1 ]
Huang, Yong [1 ]
Zhao, Yongxiang [1 ]
机构
[1] Guangxi Med Univ, Natl Ctr Int Res Biotargeting Theranost, Collaborat Innovat Ctr Targeting Tumor Diag & The, Guangxi Key Lab Biotargeting Theranost, Nanning 530021, Guangxi, Peoples R China
关键词
ACUTE LYMPHOBLASTIC-LEUKEMIA; CANCER-CELLS; RECYCLING AMPLIFICATION; FLOW-CYTOMETRY; NUCLEIC-ACID; LIVE CELLS; IN-VITRO; APTAMERS; FLUORESCENCE; DELIVERY;
D O I
10.1039/c8an02342e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Acute leukemia is a malignant clonal disease of hematopoietic stem cells with a high prevalence and mortality rate. However, there are no efficient tools to facilitate early diagnosis and treatment of leukemia. Therefore, development of new methods for the early diagnosis and prevention of leukemia, especially non-invasive diagnosis at the cellular level, is imperative. Here, a label-free signal-on fluorescence aptasensor based on terbium(III)-aptamer (Tb3+-apt) was applied for the detection of leukemia. The aptamer sensitizes the fluorescence of Tb3+ and forms the strong fluorescent Tb3+-apt probe. The target cells, the T-cell acute lymphoblastic leukemia cell line (CCRF-CEM) combined with the Tb3+-apt probe to form the Tb3+-apt-CEM complex, were removed by centrifugation, and the supernatant containing a small amount of the Tb3+-apt probe was detected using a fluorescence spectrophotometer. The logarithm of cell concentration showed a good linear relationship (R-2 = 0.9881) with the fluorescence signal. The linear range for CCRF-CEM detection was 5-5 x 106 cells per ml, while the detection limit was 5 cells per ml of the binding buffer. Clinical samples were collected from 100 cases, and the specificity and positive rates detected by this method were up to 94% and 90%, respectively. Therefore, a single-stranded DNA-sensitized terbium(III) luminescence method diagnostic was developed which is rapid, sensitive, and economical and can be used for diagnosis of various types of leukemia at the early stage.
引用
收藏
页码:3843 / 3852
页数:10
相关论文
共 50 条
  • [1] Ultrasensitive label-free aptamer-based electronic detection
    Xiang, Yun
    Xie, Mingyi
    Bash, Ralph
    Chen, Julian J. L.
    Wang, Joseph
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (47) : 9054 - 9056
  • [2] Fabrication of a novel and ultrasensitive label-free electrochemical aptasensor for detection of biomarker prostate specific antigen
    Jalalvand, Ali R.
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2019, 126 : 1065 - 1073
  • [3] A Label-Free Electrochemical Aptasensor Based on a Truncated Aptamer for the Detection of Progesterone
    Yang, Jie
    Hou, Yucui
    Ren, Yi
    Tang, Chunhua
    Li, HuanHuan
    Huang, Jing
    Jiang, Hanbing
    Cai, Tongji
    Zhao, Jia
    Yu, Peng
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2022, 18 (11) : 2498 - 2507
  • [4] A Label-Free Aptasensor for Ochratoxin a Detection Based on the Structure Switch of Aptamer
    Liu, Feng
    Ding, Ailing
    Zheng, Jiushang
    Chen, Jiucun
    Wang, Bin
    SENSORS, 2018, 18 (06)
  • [5] A Label-free aptasensor based on Aptamer/NH2 Janus particles for ultrasensitive electrochemical detection of Ochratoxin A
    Yang, Ya-Juan
    Zhou, Ying
    Xing, Yang
    Zhang, Guo-Mei
    Zhang, Yan
    Zhang, Cai-Hong
    Lei, Peng
    Dong, Chuan
    Deng, Xu
    He, Yujian
    Shuang, Shao-min
    TALANTA, 2019, 199 : 310 - 316
  • [6] A novel terbium (III) and aptamer-based probe for label-free detection of three fluoroquinolones in honey and water samples
    Chen, Jin'ai
    Jin, Yuting
    Ren, Taotao
    Wang, Shuo
    Wang, Xianghong
    Zhang, Fuyuan
    Tang, Yiwei
    FOOD CHEMISTRY, 2022, 386
  • [7] Fabrication of a Novel and Ultrasensitive Label-Free Electrochemical Aptasensor Based on Gold Nanostructure for Detection of Homocysteine
    Zaimbashi, Reza
    Tajik, Somayeh
    Beitollahi, Hadi
    Torkzadeh-Mahani, Masoud
    BIOSENSORS-BASEL, 2023, 13 (02):
  • [8] Development of a label-free electrochemical aptasensor for ultrasensitive detection of ochratoxin A
    Hou, Yujiao
    Long, Nan
    Jia, Boyu
    Liao, Xiaofang
    Yang, Minghan
    Fu, Lizhu
    Zhou, Lidong
    Sheng, Ping
    Kong, Weijun
    FOOD CONTROL, 2022, 135
  • [9] A simple label-free photoelectrochemical aptasensor for ultrasensitive detection of thrombin
    Yang, Chaonan
    Li, Zhiyuan
    Tian, Ya
    Guo, Qingfu
    Nie, Guangming
    MICROCHEMICAL JOURNAL, 2020, 159
  • [10] An Ultrasensitive Label-Free Fluorescent Aptasensor Platform for Detection of Sulfamethazine
    Wang, Yarong
    Yan, Xueling
    Kou, Qiming
    Sun, Qi
    Wang, Yuexin
    Wu, Ping
    Yang, Lulan
    Tang, Jiaming
    Le, Tao
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2021, 16 : 2751 - 2759