Sound absorption deviation measured using pressure-velocity sensors by ensemble averaging technique under different relative humidity conditions
被引:3
|作者:
Otsuru, Toru
[1
]
Tomiku, Reiji
[1
]
Okamoto, Noriko
[2
]
Yamauchi, Saki
[3
]
机构:
[1] Oita Univ, Fac Engn, 700 Dannoharu, Oita 8701192, Japan
[2] Univ Kitakyushu, Fac Environm Engn, 1-1 Hibikino, Kitakyushu, Fukuoka 8701192, Japan
[3] Oita Univ, Grad Sch, 700 Dannoharu, Oita 8701192, Japan
关键词:
Sound absorption measurement;
Pressure-velocity sensor;
Calibration;
Relative humidity;
SURFACE NORMAL IMPEDANCE;
IN-SITU TECHNIQUE;
D O I:
10.1016/j.apacoust.2017.02.015
中图分类号:
O42 [声学];
学科分类号:
070206 ;
082403 ;
摘要:
Recently, measurements using pressure-velocity sensors (pu-sensor) have come to be important in various fields of acoustics. Insufficient data exist to assure the accuracy and stability of results from measurements obtained using a pu-sensor. Herein, deviations found in the resulting absorption coefficients measured using pu-sensors were examined in relation to differences in relative humidity at the time of calibration and those at the time of absorption measurements. A series of sound absorption measurements using pu-sensors was conducted in a reverberation room under humidity control using an ensemble averaging technique proposed in reports of the authors' earlier studies. Three pu-sensors having the same specifications were used for comparison. Measurements were taken of three porous materials: both absorptive and less absorptive. Then pu-sensors were calibrated using a standing-wave-tube (SWT). Both the materials and SWT were put inside the reverberation room for more than half a day to maintain inside humidity as approximately equivalent to room conditions. The relative humidity inside the reverberation room was controlled to 40-70%. Results show that certain fluctuations occur in the amplitudes of calibration values of pressure sensors and in those of velocity sensors when the relative humidity varies from 40% to 70%: Moreover, if the difference of humidity between that at calibration and that at the time of measurement is maintained within 8%, then sound absorption can be measured stably with less deviation. The issues presented herein provide specific guidelines not only for absorption measurements but also for various applications of pu-sensors. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:121 / 127
页数:7
相关论文