Reducing Exposure to X-Ray in Patients With Conservatively Managed Distal Radius Fractures: A Closed-Loop Pilot Audit

被引:0
|
作者
Kazzam, Muattaz E. [1 ]
Clowes, Robert [1 ]
Wilson, Chris [1 ]
Walker, Lucy [1 ]
机构
[1] Dorset Cty Hosp, Trauma & Orthopaed, Dorchester, England
关键词
radiation dose reduction; cost reduction; x-ray evaluation; conservative management; hand-wrist radiograph; distal radius fractures;
D O I
10.7759/cureus.31929
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction British Orthopaedic Association Standards for Trauma (BOAST) guidelines state that a radiograph of the wrist at the time of removal of immobilisation is not required in conservatively managed distal radius fracture (DRF) patients unless there is clinical cause for concern. The aim of this pilot audit was to investigate local compliance with these guidelines. Materials and methods The first cycle of a retrospective audit was performed on conservatively managed DRF patients presenting between August and October 2021. An intervention was introduced in the form of education to highlight current guidelines. A second cycle was then performed prospectively on patients presenting between February and April 2022. Data was analysed to assess whether radiographs were taken at the time of cast removal, if the indication for the radiograph was documented and whether it affected the management plan. Results In the first cycle, 20 of 46 patients (43.5%) had repeat radiographs at the time of cast removal compared to 12 of 41 patients (29.3%) in the second cycle (p=0.170). None of the first-cycle patients had any documentation on the indication for radiograph at the time of cast removal and none of the radiographs altered the management plan. In the second cycle documentation on the indication for the radiograph was present for seven of the 12 radiographs and two altered the management plan. Conclusion Through education on adherence to national guidelines, the number of radiographs in patients with conservatively managed DRFs was reduced.
引用
收藏
页数:7
相关论文
共 27 条
  • [1] X-ray film measurements for healed distal radius fractures
    Kreder, HJ
    Hanel, DP
    McKee, M
    Jupiter, J
    McGillivary, G
    Swiontkowski, MF
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (01): : 31 - 39
  • [2] Wavefront closed-loop correction for X-ray microfocusing active optics
    Mercere, Pascal
    Idir, Mourad
    Moreno, Thierry
    Cauchon, Gilles
    Dovillaire, Guillaume
    Levecq, Xavier
    Bucourt, Samuel
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 722 - +
  • [3] Studies on Collagen Structure using X-Ray Scattering on a Closed-Loop Leather Process
    Zhang, Yi
    Mansel, Bradley W.
    Buchanan, Jenna K.
    Su, Jiasheng
    Zhang, Zhuangdou
    Holmes, Geoff
    Prabakar, Sujay
    JOURNAL OF THE AMERICAN LEATHER CHEMISTS ASSOCIATION, 2020, 115 (10): : 373 - 379
  • [4] Reference values for digital X-ray radiogrammetry parameters in children and adolescents in comparison to estimates in patients with distal radius fractures
    Diane M. Renz
    Ansgar Malich
    Andreas Ulrich
    Alexander Pfeil
    Hans-Joachim Mentzel
    Florian Streitparth
    Martin H. Maurer
    Ulf K. Teichgräber
    Joachim Böttcher
    Journal of Bone and Mineral Metabolism, 2016, 34 : 55 - 64
  • [5] Reference values for digital X-ray radiogrammetry parameters in children and adolescents in comparison to estimates in patients with distal radius fractures
    Renz, Diane M.
    Malich, Ansgar
    Ulrich, Andreas
    Pfeil, Alexander
    Mentzel, Hans-Joachim
    Streitparth, Florian
    Maurer, Martin H.
    Teichgraeber, Ulf K.
    Boettcher, Joachim
    JOURNAL OF BONE AND MINERAL METABOLISM, 2016, 34 (01) : 55 - 64
  • [6] Closed-loop filter design for X-ray pulsar-based satellite navigation system
    Qiao, Li
    Liu, Jian-Ye
    Zheng, Guang-Lou
    Xiong, Zhi
    Kongzhi Lilun Yu Yingyong/Control Theory and Applications, 2010, 27 (07): : 939 - 942
  • [7] X-ray film measurements for healed distal radius fractures (vol 21, pg 31, 1996)
    Kreder, HJ
    Hanel, DP
    McKeen, M
    Jupiter, J
    McGillivary, G
    Swiontkowski, MF
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (03): : 532 - 532
  • [8] Combination of X-ray transmission and eddy-current testing for the closed-loop recycling of aluminum alloys
    T. Takezawa
    M. Uemoto
    K. Itoh
    Journal of Material Cycles and Waste Management, 2015, 17 : 84 - 90
  • [9] Research on synchronous radiation scanning transmission X-ray microscopy system closed-loop control method
    Yao, Zhen
    Jiao, Yuchen
    Zhao, Bo
    Sun, Tianxiao
    Zhang, Yufei
    Guo, Zhi
    Wang, Yong
    Xu, Zijian
    Li, Haitao
    Liu, Haigang
    Zhang, Xiangzhi
    Tai, Renzhong
    He Jishu/Nuclear Techniques, 2024, 47 (09):
  • [10] Combination of X-ray transmission and eddy-current testing for the closed-loop recycling of aluminum alloys
    Takezawa, T.
    Uemoto, M.
    Itoh, K.
    JOURNAL OF MATERIAL CYCLES AND WASTE MANAGEMENT, 2015, 17 (01) : 84 - 90