Lissajous Curve of an Auxiliary Winding Voltage Park Components for Doubly-Fed Induction Machine Electrical Faults Diagnosis

被引:0
|
作者
El Menzhi, Lamiaa [1 ]
Saad, Abdallah [2 ]
机构
[1] Lotissement Ratibia Zitoune Meknes, Meknes, Morocco
[2] Residence ALHADIKA IB2 Bureau, Casablanca, Morocco
来源
ENERGY DEVELOPMENT, PTS 1-4 | 2014年 / 860-863卷
关键词
Doubly-fed induction machine; Auxiliary winding voltage; Diagnosis; Electrical faults; Lissajous;
D O I
10.4028/www.scientific.net/AMR.860-863.2223
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, a new method for doubly-fed induction machine electrical faults diagnosis is presented. It is based on the so-called the Lissajous curve of an auxiliary winding voltage Park components. For this purpose, time domain mathematical model of a three phase doubly-fed induction machine and expressions of the inserted winding voltage and its Park components are presented. Simulation results curried out for non defected and defected machine show the effectiveness of the proposed method.
引用
收藏
页码:2223 / +
页数:2
相关论文
共 21 条
  • [1] Induction Motor Fault Diagnosis Using Voltage Spectrum of Auxiliary Winding and Lissajous Curve of its Park Components
    El Menzhi, Lamiaa
    Saad, Abdallah
    [J]. ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 963 - +
  • [2] Dynamic Model for Brushless Doubly-Fed Machine with Stator Winding Faults
    Gorgin, Hamed
    Sotoodeh, Pedram
    Oraee, Hashem
    [J]. INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2009, 4 (06): : 1223 - 1230
  • [3] Induction Motor Fault Diagnosis Using Voltage Park Components of an Auxiliary Winding-Voltage Unbalance
    El Menzhi, L.
    Saad, A.
    [J]. 2009 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-3, 2009, : 1135 - +
  • [4] Unbalanced fault diagnosis of rotor winding in doubly-fed induction generator
    Ma, Hong-Zhong
    Li, Si-Yuan
    [J]. Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2020, 24 (02): : 138 - 143
  • [5] Research on fault diagnosis of asymmetric stator winding for doubly-fed induction generators
    Ma, Hongzhong
    Zhang, Yan
    Li, Siyuan
    Tang, Zhuozhen
    Zhang, Zhengdong
    [J]. INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION (EEEP2017), 2018, 121
  • [6] A stator voltage oriented PI controller for the doubly-fed induction machine
    Batlle, Carles
    Doria-Cerezo, Arnau
    Ortega, Romeo
    [J]. 2007 AMERICAN CONTROL CONFERENCE, VOLS 1-13, 2007, : 295 - +
  • [7] Dynamic model for doubly-fed induction generators with unbalanced excitation, both with and without winding faults
    Djurovic, S.
    Williamson, S.
    Renfrew, A.
    [J]. IET ELECTRIC POWER APPLICATIONS, 2009, 3 (03) : 171 - 177
  • [8] Impact of Unbalance Grid Voltage on the Performance of Doubly-fed Induction Machine at Motoring Mode
    Kumar, Navneet
    Chelliah, Thanga Raj
    Srivastava, Satya Prakash
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (11) : 1291 - 1306
  • [9] Analysis of doubly-fed induction machine operating at motoring mode subjected to voltage sag
    Kumar, Navneet
    Chelliah, Thanga Raj
    Srivastava, Satya Prakash
    [J]. ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2016, 19 (03): : 1117 - 1131
  • [10] Integrated diagnosis techniques of high voltage induction machine with rotor winding faults
    Ma, Hongzhong
    Jul, P.
    Wang, Donghai
    Wang, Churmin
    Li, Zheng
    [J]. IPEC: 2005 International Power Engineering Conference, Vols 1 and 2, 2005, : 7 - 10