摘要
A new modelling approach, using a combination of shell and solid elements, has been adopted to develop a realistic three-dimensional finite element (FE) model of the human scapula. Shell elements were used to represent a part of the compact bone layer (i.e. the outer cortical layer) and the very thin and rather flat part of the scapula-infraspinous fossa and supraspinous fossa respectively. Solid elements were used to model the remaining part of the compact bone and the trabecular bone. The FE model results in proper element shapes without distortion. The geometry, material properties and thickness were taken from quantitative Computed tomography (CT) data. A thorough experimental set-up for strain gauge measurement on a fresh bone serves as a reference to assess the accuracy of FE predictions. A fresh cadaveric scapula with 18 strain gauges fixed at various locations and orientations was loaded in a mechanical testing machine and supported at three locations by linkage mechanisms interconnected by ball joints. This new experimental set-up was developed to impose bending and deflection of the scapula in all directions unambiguously, in response to applied loads at various locations. The measured strains (experimental) were compared to numerical (FE) strains, corresponding to several load cases, to validate the proposed FE modelling approach. Linear regression analysis was used to assess the accuracy of the results. The percentage error in the regression slope varies between 9 and 23 per cent. It appears, as a whole, that the two variables (measured and calculated strains) strongly depend on each other with a confidence level of more than 95 per cent. Considering the complicated testing procedure on a fresh sample of scapula, the high correlation coefficients (0.89-0.97), the low standard errors (29-105 muepsilon) and percentage errors in the regression slope, as compared to other studies, strongly suggest that the strains calculated by the FE model can be used as a valid predictor of the actual measured strain. The model is therefore an alternative to a rigorous three-dimensional model based on solid elements only, which might often be too expensive in terms of computing time.
引用
收藏
页码:127 / 142
页数:16
相关论文
共 50 条
  • [1] Development and Validation of a Three-Dimensional Finite Element Model of the Face
    Barbarino, G. G.
    Jabareen, M.
    Trzewik, J.
    Nkengne, A.
    Stamatas, G.
    Mazza, E.
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (04):
  • [2] A three-dimensional finite element model of the human anterior cruciate ligament: a computational analysis with experimental validation
    Song, YH
    Debski, RE
    Musahl, V
    Thomas, M
    Woo, SLY
    [J]. JOURNAL OF BIOMECHANICS, 2004, 37 (03) : 383 - 390
  • [3] Three-dimensional finite element model to simulate secondary flows: Development and validation
    Ghanmi, A
    Robert, JL
    Khelifi, M
    [J]. JOURNAL OF HYDRAULIC RESEARCH, 1997, 35 (03) : 291 - 300
  • [4] Three-dimensional human head finite-element model validation against two experimental impacts
    Willinger, R
    Kang, HS
    Diaw, B
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1999, 27 (03) : 403 - 410
  • [5] Three-Dimensional Human Head Finite-Element Model Validation Against Two Experimental Impacts
    Remy Willinger
    Ho-Sung Kang
    Baye Diaw
    [J]. Annals of Biomedical Engineering, 1999, 27 : 403 - 410
  • [6] Development of a Three-Dimensional Finite Element Model of Spine
    Wang, Tianhao
    Li, Chenming
    Wang, Yan
    [J]. MAN-MACHINE-ENVIRONMENT SYSTEM ENGINEERING, MMESE 2018, 2019, 527 : 27 - 32
  • [7] Three-dimensional finite element simulation and experimental validation of sliding wear
    Bastola, Ajit
    Stewart, David
    Dini, Daniele
    [J]. WEAR, 2022, 504-505
  • [8] A three-dimensional finite element model of radiofrequency ablation with blood flow and its experimental validation
    Jain, MK
    Wolf, PD
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (09) : 1075 - 1084
  • [9] A Three-Dimensional Finite Element Model of Radiofrequency Ablation with Blood Flow and its Experimental Validation
    Mudit K. Jain
    Patrick D. Wolf
    [J]. Annals of Biomedical Engineering, 2000, 28 : 1075 - 1084
  • [10] Construction and validation of a three-dimensional finite element model of degenerative scoliosis
    Zheng, Jie
    Yang, Yonghong
    Lou, Shuliang
    Zhang, Dongsheng
    Liao, Shenghui
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10