Indirect Evaporative Cooling Drives Data Center Efficiency

被引:1
|
作者
Finch, Paul [1 ]
机构
[1] Kao Data, Harlow, Essex, England
关键词
Energy efficiency - Concurrency control - Evaporative cooling systems;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
A data center is a building used to house and reliably support compute, storage, and networking equipment, termed by ASHRAE Technical Committee 9.9 (TC 9.9) as information technology equipment (ITE). The reliable and energy-efficient operation of the ITE equipment is crucial for business continuity, with design strategies devised to deliver continuous availability with zero downtime. The engineering architectures include various levels of redundancy, concurrent maintainability, and backup components across the entire building infrastructure, including power, cooling, telecommunications, security, environmental controls, and power monitoring.
引用
下载
收藏
页码:40 / 47
页数:6
相关论文
共 50 条
  • [1] DESIGN ANALYSIS AND PERFORMANCE EVALUATION OF A DATA CENTER WITH INDIRECT EVAPORATIVE COOLING
    Tavakkoli, Fatemeh
    Ebrahimi, Siavash
    Sun, Xiaogang
    Cui, Yan
    Heydari, Ali
    PROCEEDINGS OF THE ASME INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, 2017, 2017,
  • [2] CFD MODELING OF INDIRECT/DIRECT EVAPORATIVE COOLING UNIT FOR MODULAR DATA CENTER APPLICATIONS
    Gebrehiwot, Betsegaw
    Dhiman, Nikhil
    Rajagopalan, Kasturi
    Agonafer, Dereje
    Kannan, Naveen
    Hoverson, James
    Kaler, Mike
    PROCEEDINGS OF THE ASME INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, 2013, VOL 2, 2014,
  • [3] Expanding the Envelope for Indirect/Direct Evaporative Data Center Cooling Using Thermal Energy Storage
    Luttrell, Jeff
    Guhe, Abhishek
    Agonafer, Dereje
    2016 32ND THERMAL MEASUREMENT, MODELING & MANAGEMENT SYMPOSIUM (SEMI-THERM), 2016, : 163 - 170
  • [4] Experimental investigation of an optimized indirect free cooling system including a dry cooler equipped with evaporative cooling pads for data center
    Hnayno, Mohamad
    Chehade, Ali
    Klaba, Henryk
    Polidori, Guillaume
    Maalouf, Chadi
    ENERGY REPORTS, 2023, 9 : 460 - 469
  • [5] Experimental investigation of an optimized indirect free cooling system including a dry cooler equipped with evaporative cooling pads for data center
    Hnayno, Mohamad
    Chehade, Ali
    Klaba, Henryk
    Polidori, Guillaume
    Maalouf, Chadi
    ENERGY REPORTS, 2023, 9 : 460 - 469
  • [6] Climatic applicability of indirect evaporative cooling strategies for data centers in China
    Cui, Xin
    Yang, Chuanjun
    Yan, Weichao
    Wang, Xinyu
    Liu, Yahui
    Jin, Liwen
    JOURNAL OF BUILDING ENGINEERING, 2024, 83
  • [7] INDIRECT/DIRECT EVAPORATIVE COOLING SYSTEMS
    Eskra, Neil
    ASHRAE Journal, 1980, 22 (05) : 21 - 25
  • [8] A review of indirect evaporative cooling technology
    Porumb, Bogdan
    Unguresan, Paula
    Tutunaru, Lucian Fechete
    Serban, Alexandru
    Balan, Mugur
    EENVIRO-YRC 2015 - BUCHAREST, 2016, 85 : 461 - 471
  • [9] Efficiency Analysis of Cross-Flow Plate Heat Exchanger for Indirect Evaporative Cooling
    Liu, Xuelai
    Li, Yong'an
    Li, Jizhi
    Yang, Hongxing
    Chen, Hengliang
    SUSTAINABILITY IN ENERGY AND BUILDINGS, 2009, : 255 - +
  • [10] Application of indirect evaporative cooling to variable domestic cooling load
    Joudi, KA
    Mehdi, SM
    ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (17) : 1931 - 1951