The effects of ionisation density on the thermoluminescence response (efficiency) of LiF:Mg,Ti and LiF:Mg,Cu,P

被引:39
|
作者
Horowitz, Y [1 ]
Olko, P
机构
[1] Ben Gurion Univ Negev, Dept Phys, IL-84105 Beer Sheva, Israel
[2] Inst Nucl Phys, PL-31342 Krakow, Poland
关键词
D O I
10.1093/rpd/nch310
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, the various models dealing with the effects of ionisation density on the thermoluminescence (TL) response (efficiency) of TL LiF dosemeters are discussed. These include (i) the Unified Interaction Model (UNIM), which models photon/electron linear/supralinear dose response; (ii) the Extended Track Interaction Model (ETIM), which models heavy charged particle (HCP) TL fluence response; (iii) Modified Track Structure Theory (MTST), which models relative HCP TL efficiencies; and (iv) Microdosimetric Target Theory (MTT), which models both relative HCP efficiencies and photon energy response.
引用
收藏
页码:331 / 348
页数:18
相关论文
共 50 条
  • [1] Optical and thermoluminescence properties of LiF:Cu, LiF:Mg,Cu and LiF:Mg,Cu,P single crystals
    Chernov, V
    Mironenko, S
    Rogalev, B
    Bos, AJJ
    de Haas, JTM
    Delgado, A
    RADIATION MEASUREMENTS, 1998, 29 (3-4) : 365 - 372
  • [2] Thermoluminescence of nanocrystalline LiF:Mg, Cu, P
    Salah, Numan
    Sahare, P. D.
    Rupasov, A. A.
    JOURNAL OF LUMINESCENCE, 2007, 124 (02) : 357 - 364
  • [3] Comparison between the low temperature thermoluminescence spectra in annealed LiF:Mg,Cu, LiF:Mg,Cu,P and LiF:Mg,Cu,Si
    Yang, B.
    Wang, L.
    Townsend, P. D.
    Gao, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (11): : 2581 - 2586
  • [4] Comparison of the effects of exposure to light in Harshaw LiF:Mg,Ti and LiF:Mg,Cu,P
    Baker, S. T.
    Gilvin, P. J.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 258 - 260
  • [5] Evaluation of the relative thermoluminescence efficiency of LiF:Mg,Ti and LiF:Mg,Cu,P TL detectors to low-energy heavy ions
    Gieszczyk, W.
    Bilski, P.
    Olko, P.
    Herrmann, R.
    Kettunen, H.
    Virtanen, A.
    Bassler, N.
    RADIATION MEASUREMENTS, 2013, 51-52 : 7 - 12
  • [6] Lithium fluoride:: From LiF:Mg,Ti to LiF:Mg,Cu,P
    Bilski, P
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 199 - 206
  • [7] Lithium fluoride:: From LiF:Mg,Ti to LiF:Mg,Cu,P
    Bilski, P
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 199 - 206
  • [9] Studies on the thermoluminescence spectra and thermal stability of LiF:Mg,Cu, LiF:Mg,Cu,Na and LiF:Mg,Cu,Si
    Yang, B
    Lu, Q
    Wang, S
    Townsend, PD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 239 (03): : 171 - 178
  • [10] Role of dopants in LiF:Mg,Cu, LiF:Mg,P and LiF:Mg,Cu,P detectors
    Mohammadi, Kh
    Zarandi, A. Moussavi
    Afarideh, H.
    Shahmaleki, S.
    JOURNAL OF SOLID STATE CHEMISTRY, 2013, 202 : 282 - 290