Analytical Method Validation for Estimation of Neurotransmitters (Biogenic Monoamines) from Cerebrospinal Fluid Using High Performance Liquid Chromatography

被引:9
|
作者
Lokhande, Rohan V. [1 ,2 ]
Bhagure, Ganesh R. [2 ]
Dherai, Alpa J. [1 ]
Naik, Prasad R. [1 ]
Udani, Vrajesh P. [3 ]
Desai, Neelu A. [3 ]
Ashavaid, Tester F. [1 ]
机构
[1] PD Hinduja Hosp & MRC, Dept Lab Med, Biochem Sect, Mumbai, Maharashtra, India
[2] Satish Pradhan Dnyanasadhana Coll, Dept Chem, Thana, India
[3] PD Hinduja Hosp & MRC, Dept Paediat Neurol, Mumbai, Maharashtra, India
关键词
Cerebrospinal fluid; Biogenic monoamine; HPLC; Validation; Abnormal neurotransmitter; DISORDERS;
D O I
10.1007/s12291-020-00949-8
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Biogenic amine neurotransmitters such as serotonin and dopamine are essential for signaling in both central and peripheral nervous system. Their metabolism is a multistep pathway and any defect in this results in alteration in metabolites of serotonin 5-Hydroxyindole acetic acid (5HIAA) and dopamine homovanillic acid (HVA) and 3-O-Methyl Dopa (3-OMD). Estimation of these metabolites in cerebrospinal fluid (CSF) assists in diagnosis of neurotransmitter defects. Their estimation is technically demanding and is currently available only in referral centers. We aimed to optimize a method for analysis of 5HIAA, HVA and 3-OMD. A high performance liquid chromatography (HPLC) method with electro chemical detector (ECD) was standardized for estimation. Analysis for method validation, reference range verification and clinical correlation was performed. Linearity obtained for 5-HIAA, HVA and 3-OMD was 65.35-2615.0 nmoles/l, 68.62-2745.0 nmoles/l and 236.5-4730.0 nmoles/l respectively. The coefficient of variation for internal quality controls ranged from 5 to 14% and the external proficiency testing samples (n = 16) were within peer group range. CSF metabolite levels of samples for reference range analysis overlapped with age matched ranges reported in literature. Among the 40 suspected patients analyzed for clinical testing four were found to have a neurotransmitter defect. These patients were then confirmed with molecular testing and clinical correlation. The method is validated and can be adapted in a clinical laboratory with analytical competence in HPLC.
引用
收藏
页码:85 / 92
页数:8
相关论文
共 50 条
  • [1] Analytical Method Validation for Estimation of Neurotransmitters (Biogenic Monoamines) from Cerebrospinal Fluid Using High Performance Liquid Chromatography
    Rohan V. Lokhande
    Ganesh R. Bhagure
    Alpa J. Dherai
    Prasad R. Naik
    Vrajesh P. Udani
    Neelu A. Desai
    Tester F. Ashavaid
    Indian Journal of Clinical Biochemistry, 2022, 37 : 85 - 92
  • [2] ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF TAMOXIFEN CITRATE USING NORMAL PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
    Yerlikaya, Firat
    Launay, Manon
    Gegu, Clement
    Leturgez, Thibaut
    Bilensoy, Erem
    Calis, Sema
    Capan, Yilmaz
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2009, 38 (01) : 183 - 184
  • [3] Analytical Method Development and Validation for Estimation of Emtricitabine in Tablet Dosage Form by Reverse Phase High Performance Liquid Chromatography
    Rathod, Shital
    Chopade, Jyotsana
    Mahaparale, Sonali
    Jadhao, Y. P.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2024, 86 (01) : 294 - 301
  • [4] DEVELOPMENT AND VALIDATION OF ANALYTICAL METHOD FOR DETERMINATION OF TIBOLONE IN CAPSULES BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
    da Rosa, Hernandez Bozardi
    Tolotti, Renata Cristine
    Miron, Diogo dos Santos
    Borges de Souza, Kellen Cristhinia
    QUIMICA NOVA, 2012, 35 (05): : 1030 - 1035
  • [5] DEVELOPMENT AND VALIDATION OF AN ANALYTICAL METHOD FOR QUANTITATION OF THE DRUG BEVACIZUMAB BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
    de Lima Gomes, Elionai Cassiana
    Cunha Junior, Armando da Silva
    Yoshida, Maria Irene
    Jorge, Rodrigo
    QUIMICA NOVA, 2012, 35 (03): : 608 - 611
  • [6] Development and validation of an analytical method for Nystatin vaginal cream by high performance liquid chromatography
    Maciel Lavra, Zenia Maria
    Sonego, Fabiane
    Ferreira da Silva, Rosali Maria
    Morais de Medeiros, Flavia Patricia
    REVISTA BRASILEIRA DE CIENCIAS FARMACEUTICAS, 2008, 44 (04): : 637 - 643
  • [7] Development and validation of an analytical method for the determination of histamine in wines using high performance liquid chromatography with fluorescence detection
    Prestes, Osmar D.
    Presta, Michele A.
    Kolberg, Diana I. S.
    Zanella, Renato
    Rossato, Simone B.
    Penna, Neidi G.
    Hecktheuer, Luisa H. R.
    QUIMICA NOVA, 2007, 30 (01): : 18 - 21
  • [8] Measurement of resiniferatoxin in cerebrospinal fluid by high-performance liquid chromatography
    Mannes, AJ
    Brown, DC
    Perkowski, SZ
    Keller, J
    Caudle, RM
    Iadarola, MJ
    Mengc, QC
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (02): : 475 - 479
  • [9] MONOAMINES AND THEIR METABOLITES IN CEREBROSPINAL-FLUID OF PATIENTS WITH SENILE DEMENTIA OF ALZHEIMER TYPE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    PARNETTI, L
    GOTTFRIES, J
    KARLSSON, I
    LANGSTROM, G
    GOTTFRIES, CG
    SVENNERHOLM, L
    ACTA PSYCHIATRICA SCANDINAVICA, 1987, 75 (05) : 542 - 548
  • [10] ANALYTICAL METHOD DEVELOPMENT FOR SIMULTANEOUS ESTIMATION OF OXYBENZONE, OCTOCRYLENE, OCTINOXATE AND AVOBENZONE IN SUNSCREEN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY AND ITS VALIDATION
    Bhuva, Chirag
    Singh, Rambir
    Sharma, Anil
    PHARMACOPHORE, 2012, 3 (02): : 130 - 155