Effects of Waveguide Refractive Index on Near-Field Transducer Efficiency in Heat-Assisted Magnetic Recording

被引:2
|
作者
Cen, Z. H. [1 ]
Xu, B. X. [1 ]
Toh, Y. T. [1 ]
Li, J. M. [1 ]
Ye, K. D. [1 ]
Zhang, J. [1 ]
机构
[1] Agcy Sci Technol & Res, Data Storage Inst, Singapore 117608, Singapore
关键词
Finite-difference time domain (FDTD) simulation; heat-assisted magnetic recording (HAMR); Si waveguide; transducer efficiency; waveguide refractive index; OPTICAL-ENERGY TRANSFER; THIN-FILM; ANTENNA;
D O I
10.1109/TMAG.2015.2437914
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In a heat-assisted magnetic recording (HAMR) system, optical power is delivered by the waveguide to interact with the near-field transducer. The influence of optical properties of waveguide core on transducer efficiency has been investigated by using finitedifference time domain simulations. It is observed that the waveguide core of large refractive index can improve transducer efficiency due to more effective exploitation of light power by the transducer. In addition, smaller power is absorbed by the transducer in a HAMR system of larger waveguide core refractive index during operation, which can result in better transducer thermal stability. With the knowledge of effects of large waveguide core refractive index, employing silicon (Si) waveguide in a HAMR system working at near-infrared wavelengths has been proposed to enhance transducer efficiency. Effects of Si waveguide core geometry on transducer performance have been analyzed. A high transducer efficiency of 9.2% at 1200 nm can be achieved in a HAMR system with a Si waveguide of optimized core size.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Influence of waveguide refractive index on near-field transducer efficiency in heat-assisted magnetic recordin.
    Cen, Z.
    Xu, B.
    Toh, Y.
    Li, J.
    Ye, K.
    Zhang, J.
    2015 IEEE MAGNETICS CONFERENCE (INTERMAG), 2015,
  • [2] Plasmonic near-field transducer for heat-assisted magnetic recording
    Zhou, Nan
    Xu, Xianfan
    Hammack, Aaron T.
    Stipe, Barry C.
    Gao, Kaizhong
    Scholz, Werner
    Gage, Edward C.
    NANOPHOTONICS, 2014, 3 (03) : 141 - 155
  • [3] Infrared Near-Field Transducer for Heat-Assisted Magnetic Recording
    Datta, Anurup
    Xu, Xianfan
    IEEE TRANSACTIONS ON MAGNETICS, 2017, 53 (12)
  • [4] Novel droplet near-field transducer for heat-assisted magnetic recording
    Gosciniak, Jacek
    Mooney, Marcus
    Gubbins, Mark
    Corbett, Brian
    NANOPHOTONICS, 2015, 4 (04) : 503 - 510
  • [5] Improved Near-Field Transducer Design for Heat-Assisted Magnetic Recording
    Datta, Anurup
    Xu, Xianfan
    IEEE TRANSACTIONS ON MAGNETICS, 2016, 52 (12)
  • [6] Nanoscale ridge aperture as near-field transducer for heat-assisted magnetic recording
    Zhou, Nan
    Kinzel, Edward C.
    Xu, Xianfan
    APPLIED OPTICS, 2011, 50 (31) : G42 - G46
  • [7] Design for cooling near-field transducer using surface plasmon polariton waveguide for heat-assisted magnetic recording
    Nakagawa, Katsuji
    Kimura, Kousuke
    Hayashi, Yoshihiko
    Tamura, Kyosuke
    Ashizawa, Yoshito
    Ohnuki, Shinichiro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2018, 57 (09)
  • [8] Heat-assisted magnetic recording by a near-field transducer with efficient optical energy transfer
    Challener, W. A.
    Peng, Chubing
    Itagi, A. V.
    Karns, D.
    Peng, Wei
    Peng, Yingguo
    Yang, XiaoMin
    Zhu, Xiaobin
    Gokemeijer, N. J.
    Hsia, Y. -T.
    Ju, G.
    Rottmayer, Robert E.
    Seigler, Michael A.
    Gage, E. C.
    NATURE PHOTONICS, 2009, 3 (04) : 220 - 224
  • [9] Temperature-Induced Near-Field Transducer Failure in Heat-Assisted Magnetic Recording
    Trinh, Tan D.
    Rajauria, Sukumar
    Smith, Robert
    Schreck, Erhard
    Dai, Qing
    Talke, Frank E.
    IEEE TRANSACTIONS ON MAGNETICS, 2020, 56 (06)
  • [10] Efficiency Analysis of Near Field Optical Transducer Used in Heat-Assisted Magnetic Recording
    Xu, Baoxi
    Cen, Zhanhong
    Toh, Yeow Teck
    Li, Jianming
    Ye, Kaidong
    Zhang, Jing
    IEEE TRANSACTIONS ON MAGNETICS, 2013, 49 (07) : 3580 - 3583