Quantitative CEST imaging of amide proton transfer in acute ischaemic stroke
被引:42
|作者:
Msayib, Y.
[1
]
Harston, G. W. J.
[2
]
Tee, Y. K.
[3
]
Sheerin, F.
[2
]
Blockley, N. P.
[4
]
Okell, T. W.
[4
]
Jezzard, P.
[4
]
Kennedy, J.
[2
]
Chappell, M. A.
[1
,4
]
机构:
[1] Univ Oxford, Inst Biomed Engn, Dept Engn Sci, Oxford, England
[2] Univ Oxford, Acute Vasc Imaging Ctr, Radcliffe Dept Med, Oxford, England
[3] Univ Tunku Abdul Rahman, Dept Mechatron & Biomed Engn, Lee Kong Chian Fac Engn & Sci, Kampar, Negeri Perak, Malaysia
[4] Univ Oxford, Wellcome Ctr Integrat Neuroimaging, Nuffield Dept Clin Neurosci, FMRIB Div, Oxford, England
基金:
英国工程与自然科学研究理事会;
英国惠康基金;
关键词:
Chemical exchange saturation transfer;
Amide proton transfer;
Nuclear Overhauser effects;
Acute ischaemic stroke;
EXCHANGE SATURATION-TRANSFER;
NUCLEAR OVERHAUSER ENHANCEMENT;
TRANSFER APT;
IN-VIVO;
BRAIN;
MRI;
QUANTIFICATION;
REGISTRATION;
ROBUST;
MODEL;
D O I:
10.1016/j.nicl.2019.101833
中图分类号:
R445 [影像诊断学];
学科分类号:
100207 ;
摘要:
Background: Amide proton transfer (APT) imaging may help identify the ischaemic penumbra in stroke patients, the classical definition of which is a region of tissue around the ischaemic core that is hypoperfused and metabolically stressed. Given the potential of APT imaging to complement existing imaging techniques to provide clinically-relevant information, there is a need to develop analysis techniques that deliver a robust and repeatable APT metric. The challenge to accurate quantification of an APT metric has been the heterogeneous in-vivo environment of human tissue, which exhibits several confounding magnetisation transfer effects including spectrally-asymmetric nuclear Overhauser effects (NOEs). The recent literature has introduced various model-free and model-based approaches to analysis that seek to overcome these limitations. Objectives: The objective of this work was to compare quantification techniques for CEST imaging that specifically separate APT and NOE effects for application in the clinical setting. Towards this end a methodological comparison of different CEST quantification techniques was undertaken in healthy subjects, and around clinical endpoints in a cohort of acute stroke patients. Methods: MRI data from 12 patients presenting with ischaemic stroke were retrospectively analysed. Six APT quantification techniques, comprising model-based and model-free techniques, were compared for repeatability and ability for APT to distinguish pathological tissue in acute stroke. Results: Robustness analysis of six quantification techniques indicated that the multi-pool model-based technique had the smallest contrast between grey and white matter (2%), whereas model-free techniques exhibited the highest contrast ( > 30%). Model-based techniques also exhibited the lowest spatial variability, of which 4-pool APTR* was by far the most uniform (10% coefficient of variation, CoV), followed by 3-pool analysis (20%). Four-pool analysis yielded the highest ischaemic core contrast-to-noise ratio (0.74). Four-pool modelling of APT effects was more repeatable (3.2% CoV) than 3-pool modelling (4.6% CoV), but this appears to come at the cost of reduced contrast between infarct growth tissue and normal tissue. Conclusion: The multi-pool measures performed best across the analyses of repeatability, spatial variability, contrast-to-noise ratio, and grey matter-while matter contrast, and might therefore be more suitable for use in clinical imaging of acute stroke. Addition of a fourth pool that separates NOEs and semisolid effects appeared to be more biophysically accurate and provided better separation of the APT signal compared to the 3-pool equivalent, but this improvement appeared be accompanied by reduced contrast between infarct growth tissue and normal tissue.