Development and use of a high-fidelity simulator for fetal endotracheal balloon occlusion (FETO) insertion and removal

被引:16
|
作者
Windrim, Rory [1 ,2 ]
Ryan, Greg [1 ,2 ]
LeBouthillier, Francis [3 ]
Campisi, Paolo [2 ,4 ]
Kelly, Edmond N. [2 ,5 ]
Baud, David [1 ,2 ]
Yoo, Shi-Joon [2 ,6 ]
Deprest, Jan [7 ]
机构
[1] Mt Sinai Hosp, Fetal Med Unit, Toronto, ON M5G 1X5, Canada
[2] Univ Toronto, Toronto, ON M5S 1A1, Canada
[3] Ontario Art & Design Univ, Dept Sculpture, Toronto, ON, Canada
[4] Hosp Sick Children, Dept Otolaryngol Head & Neck Surg, Toronto, ON M5G 1X8, Canada
[5] Mt Sinai Hosp, Dept Neonatol, Toronto, ON M5G 1X5, Canada
[6] Hosp Sick Children, Dept Diagnost Imaging, Toronto, ON M5G 1X8, Canada
[7] Univ Hosp Gasthuisberg, Dept Obstet & Gynaecol, Fetal Med Unit, B-3000 Louvain, Belgium
基金
英国惠康基金;
关键词
CONGENITAL DIAPHRAGMATIC-HERNIA; ENDOSCOPIC TRACHEAL OCCLUSION; RANDOMIZED-CONTROLLED-TRIAL; MEDICAL-EDUCATION; LAMB MODEL; SEE ONE; PERFORMANCE; CORDOCENTESIS; SKILLS; LUNG;
D O I
10.1002/pd.4284
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
Objectives The objective of this article is to describe the development of an anatomically accurate simulator in order to aid the training of a perinatal team in the insertion and removal of a fetal endoscopic tracheal occlusion (FETO) balloon in the management of prenatally diagnosed congenital diaphragmatic hernia. Methods An experienced perinatal team collaborated with a medical sculptor to design a fetal model for the FETO procedure. Measurements derived from 28-week fetal magnetic resonance imaging were used in the development of an anatomically precise simulated airway within a silicone rubber preterm fetal model. Clinician feedback was then used to guide multiple iterations of the model with serial improvements in the anatomic accuracy of the simulator airway. Results An appropriately sized preterm fetal mannequin with a high-fidelity airway was developed. The team used this model to develop surgical skills with balloon insertion, and removal, and to prepare the team for an integrated response to unanticipated delivery with the FETO balloon still in situ. Conclusions This fetal mannequin aided in the ability of a fetal therapy unit to offer the FETO procedure at their center for the first time. This model may be of benefit to other perinatal centers planning to offer this procedure.
引用
收藏
页码:180 / 184
页数:5
相关论文
共 39 条
  • [1] Letter: Development of a Novel High-Fidelity Simulator for Teaching In Utero Fetal Shunting
    Windrim, Rory
    Gregory, Caroline
    Keunen, Johannes
    Abbasi, Nimrah
    Ryan, Greg
    Van Mieghem, Tim
    LeBouthillier, Francis
    Seaward, Gareth
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA, 2020, 42 (11) : 1318 - 1319
  • [2] Development and Evaluation of a High-Fidelity Rhinoplasty Simulator
    Podolsky, Dale J.
    Murphy, Blake D.
    Ahmad, Jamil
    Fisher, David M.
    Riff, Karen W. Y. Wong
    Drake, James M.
    Forrest, Christopher R.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2024, 153 (03) : 619 - 622
  • [3] Development of a high-fidelity CLARREO Pathfinder simulator
    Wu, Wan
    Liu, Xu
    Yang, Qiguang
    Goldin, Daniel
    Shea, Yolanda L.
    Currey, Jon C.
    Bartle, Aron
    Lukashin, Constantine
    IGARSS 2020 - 2020 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, 2020, : 6385 - 6388
  • [4] DEVELOPMENT AND VALIDATION OF A HIGH-FIDELITY URETHRAL CATHETER SIMULATOR
    Schul, Alyssa
    Gong, Alex
    Sweet, Robert
    JOURNAL OF UROLOGY, 2019, 201 (04): : E510 - E511
  • [5] Development and Validation of a High-Fidelity Neonatal Pneumothorax Simulator
    Maglio, S.
    Tognarelli, S.
    Ciantelli, M.
    Menciassi, A.
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2021, 3 (04): : 900 - 908
  • [6] A Modular High-Fidelity Photorealistic Simulator of Orbital Scenarios: A Space Debris Removal Use Case
    Li, Xiao
    Richard, Antoine
    Yalcin, Baris C.
    Delisle, Maxime Hubert
    Olivares-Mendez, Miguel
    Martinez, Carol
    2024 INTERNATIONAL CONFERENCE ON SPACE ROBOTICS, ISPARO, 2024, : 111 - 118
  • [7] Development and Validation of a High-Fidelity Porcine Laryngeal Surgical Simulator
    Dedmon, Matthew M.
    Paddle, Paul M.
    Phillips, Jeananne
    Kobayashi, Leo
    Franco, Ramon A.
    Song, Phillip C.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2015, 153 (03) : 420 - 426
  • [8] Development of a High-Fidelity Simulator for Teaching Chorionic Villus Sampling
    El-Chaar, Darine
    Manley, Jennifer
    LeBouthillier, Francis
    Ryan, Greg
    Windrim, Rory
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA, 2018, 40 (09) : 1178 - 1181
  • [9] Letter: Development of a High-Fidelity Surgical Simulator for Invasive Placentation
    Jones, Makaela
    Windrim, Rory
    Janeteas, Conner
    Kazlovich, Kate
    Phillips, John
    Lizama, Tatiana Freire
    Zelko, Sue
    Murji, Ally
    Kfouri, Julia
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA, 2021, 43 (01) : 7 - 8
  • [10] DEVELOPMENT AND USE OF A HIGH-FIDELITY TRACTOR DRIVING SIMULATOR TO EXAMINE THE EFFECT OF AGE ON CRASH RISK
    Faust, K.
    Casteel, C.
    McGehee, D.
    Rohlman, D.
    Peek-Asa, C.
    Ramirez, M.
    INJURY PREVENTION, 2021, 27 : A15 - A16