Digital versus conventional implant impressions for partially edentulous arches: An evaluation of accuracy

被引:85
|
作者
Marghalani, Amin [1 ,2 ]
Weber, Hans-Peter [1 ]
Finkelman, Matthew [3 ]
Kudara, Yukio [1 ]
El Rafie, Khaled [1 ]
Papaspyridakos, Panos [1 ]
机构
[1] Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, One Kneeland St, Boston, MA 02111 USA
[2] Umm Al Qura Univ, Coll Dent, Mecca, Saudi Arabia
[3] Tufts Univ, Sch Dent Med, Dept Publ Hlth & Community Serv, Boston, MA 02111 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2018年 / 119卷 / 04期
关键词
IN-VITRO; DENTAL IMPLANTS; TECHNOLOGY; POLYETHER; PROSTHESES; OUTCOMES; FIT;
D O I
10.1016/j.prosdent.2017.07.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. To the authors' knowledge, while accuracy outcomes of the TRIOS scanner have been compared with conventional impressions, no available data are available regarding the accuracy of digital scans with the Omnicam and True Definition scanners versus conventional impressions for partially edentulous arches. Purpose. The purpose of this in vitro study was to compare the accuracy of digital implant scans using 2 different intraoral scanners (IOSs) with that of conventional impressions for partially edentulous arches. Material and methods. Two partially edentulous mandibular casts with 2 implant analogs with a 30-degree angulation from 2 different implant systems (Replace Select RP; Nobel Biocare and Tissue level RN; Straumann) were used as controls. Sixty digital models were made from these 2 definitive casts in 6 different groups (n=10). Splinted implant-level impression procedures followed by digitization were used to produce the first 2 groups. The next 2 groups were produced by digital scanning with Omnicam. The last 2 groups were produced by digital scanning with the True Definition scanner. Accuracy was evaluated by superimposing the digital files of each test group onto the digital file of the controls with inspection software. Results. The difference in 3-dimensional (3D) deviations (median interquartile range) among the 3 impression groups for Nobel Biocare was statistically significant among all groups (P<.001), except for the Omnicam (20 +/- 4 mu m) and True Definition (15 +/- 6 mu m) groups; the median +/- interquartile range for the conventional group was 39 +/- 18 mu m. The difference in 3D deviations among the 3 impression groups for Straumann was statistically significant among all groups (P=.003), except for the conventional impression (22 +/- 5 mu m) and True Definition (17 +/- 5 mu m) groups; the median interquartile range for the Omnicam group was 26 +/- 15 mu m. The difference in 3D deviations between the 2 implant systems was significant for the Omnicam (P=.011) and conventional (P<.001) impression techniques but not for the True Definition technique (P=.247). Conclusions. Within the limitations of this study, both the impression technique and the implant system affected accuracy. The True Definition technique had the fewest 3D deviations compared with the other 2 techniques; however, the accuracy of all impression techniques was within clinically acceptable levels, and not all differences were statistically significant.
引用
收藏
页码:574 / 579
页数:6
相关论文
共 50 条
  • [1] Digital versus conventional implant impressions for edentulous patients: accuracy outcomes
    Papaspyridakos, Panos
    Gallucci, German O.
    Chen, Chun-Jung
    Hanssen, Stijn
    Naert, Ignace
    Vandenberghe, Bart
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (04) : 465 - 472
  • [2] In vitro accuracy of digital and conventional impressions in the partially edentulous maxilla
    Waldecker, Moritz
    Rues, Stefan
    Awounvo Awounvo, Junior Sinclair
    Rammelsberg, Peter
    Boemicke, Wolfgang
    [J]. CLINICAL ORAL INVESTIGATIONS, 2022, 26 (11) : 6491 - 6502
  • [3] In vitro accuracy of digital and conventional impressions in the partially edentulous maxilla
    Moritz Waldecker
    Stefan Rues
    Junior Sinclair Awounvo Awounvo
    Peter Rammelsberg
    Wolfgang Bömicke
    [J]. Clinical Oral Investigations, 2022, 26 : 6491 - 6502
  • [4] Accuracy of digital versus conventional implant impressions
    Lee, Sang J.
    Betensky, Rebecca A.
    Gianneschi, Grace E.
    Gallucci, German O.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (06) : 715 - 719
  • [5] Accuracy of Implant Impressions for Partially and Completely Edentulous Patients: A Systematic Review
    Papaspyridakos, Panos
    Chen, Chun-Jung
    Gallucci, German O.
    Doukoudakis, Asterios
    Weber, Hans-Peter
    Chronopoulos, Vasilios
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (04) : 836 - +
  • [6] THE ACCURACY OF INTRAORAL SCAN IN OBTAINING DIGITAL IMPRESSIONS OF EDENTULOUS ARCHES: A SYSTEMATIC REVIEW
    Wang, Yiyang
    Li, Yaning
    Liang, Shanshan
    Yuan, Fusong
    Liu, Yunsong
    Ye, Hongqiang
    Zhou, Yongsheng
    [J]. JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2024, 24 (01)
  • [7] 3D Accuracy of a Conventional Method Versus Three Digital Scanning Strategies for Completely Edentulous Maxillary Implant Impressions
    Blanco-Plard, Arturo
    Hernandez, Ana
    Pino, Fernando
    Vargas, Nadyan
    Rivas-Tumanyan, Sona
    Elias, Augusto
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (06) : 1211 - 1219
  • [8] Accuracy of Casts Fabricated by Digital and Conventional Implant Impressions
    Bohner, Lauren
    Hanisch, Marcel
    Canto, Graziela De Luca
    Mukai, Eduardo
    Sesma, Newton
    Tortamano Neto, Pedro
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (02) : 94 - 99
  • [9] Digital Versus Conventional Full-Arch Implant Impressions: A Prospective Study on 16 Edentulous Maxillae
    Chochlidakis, Konstantinos
    Papaspyridakos, Panos
    Tsigarida, Alexandra
    Romeo, Davide
    Chen, Yo-wei
    Natto, Zuhair
    Ercoli, Carlo
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (04): : 281 - 286
  • [10] Three-Dimensional Accuracy of Conventional Versus Digital Complete Arch Implant Impressions
    Albayrak, Berkman
    Sukotjo, Cortino
    Wee, Alvin G.
    Korkmaz, Ismail Hakki
    Bayindir, Funda
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (02): : 163 - 170