Two-Year Reproducibility of Axial Length Measurements after Combined Phacovitrectomy for Epiretinal Membrane, and Refractive Outcomes

被引:10
|
作者
Kang, Tae Seen [1 ,2 ]
Shin, Yong-Il [1 ]
Ryu, Cheon Kuk [1 ]
Kim, Jung Yeul [1 ]
机构
[1] Chungnam Natl Univ Hosp, Dept Ophthalmol, Daejeon 35015, South Korea
[2] Gyeongsang Natl Univ, Dept Ophthalmol, Changwon Hosp, Chang Won 51472, South Korea
关键词
axial length; combined phacovitrectomy; reproducibility; postoperative prediction errors; INTRAOCULAR-LENS POWER; PARS-PLANA VITRECTOMY; CATARACT-SURGERY; COMBINED PHACOEMULSIFICATION; OPTICAL BIOMETRY; ERROR; EYES; ACCURACY; REMOVAL;
D O I
10.3390/jcm9113493
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To determine the long-term reproducibility of axial length measurements and mean postoperative prediction errors after combined phacovitrectomy in patients with idiopathic epiretinal membranes. Design: Retrospective cohort study. Methods: The study included 43 patients who underwent combined phacovitrectomy and 30 patients who underwent only phacoemulsification. To determine the effect of vitrectomy, we compared patients treated with phacoemulsification only versus those treated with combined phacovitrectomy. Axial lengths were measured three times with a one-year interval, and the intraclass correlation coefficient (ICC), coefficient of variation (CV), and test-retest standard deviation (TRTSD) were assessed. Results: There was no significant change in axial length, and axial length measurements showed high reproducibility in all groups. ICC, CV, and TRTSD values were 0.997, 0.24%, and 0.056, respectively, for the vitrectomized eyes. The mean postoperative prediction error was -0.37 diopters(D) in vitrectomized eyes (p < 0.001), while it was +0.11 D in patients with phacoemulsification (p = 0.531). The myopic shift was more obvious in eyes with a shallower anterior chamber (p = 0.008) and a thicker lens (p = 0.025). Conclusions: Axial length measurements showed excellent long-term reproducibility at 2 years after combined phacovitrectomy. Myopic shifts were observed after combined phacovitrectomy, which was probably due to changes in the effective lens position after combined phacovitrectomy, rather than to changes in the axial length.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [1] REFRACTIVE OUTCOMES AFTER PHACOVITRECTOMY FOR MACULAR HOLE AND EPIRETINAL MEMBRANE
    Mazzini, C.
    Miele, A.
    Biagini, I
    Rizzo, S.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (02) : E63 - E63
  • [2] Postoperative refractive outcomes in eyes undergoing combined phacovitrectomy surgery for epiretinal membrane
    Heriot, Wilson J.
    El Ali, Oubada
    Vukicevic, Meri
    Koklanis, Konstandina
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 51 (09): : 1028 - 1028
  • [3] Refractive outcomes of 8 biometric formulas in combined phacovitrectomy with internal limiting membrane peeling for epiretinal membrane
    Vounotrypidis, Efstathios
    Shajari, Mehdi
    Muth, Daniel R.
    Hirnschall, Nino
    Findl, Oliver
    Priglinger, Siegfried
    Mayer, Wolfgang J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (04): : 591 - 597
  • [4] Two-Year Refractive Outcomes After Descemet Membrane Endothelial Keratoplasty
    van Dijk, Korine
    Rodriguez-Calvo-de-Mora, Marina
    van Esch, Hilde
    Frank, Laurence
    Dapena, Isabel
    Baydoun, Lamis
    Oellerich, Silke
    Melles, Gerrit R. J.
    CORNEA, 2016, 35 (12) : 1548 - 1555
  • [5] Refractive changes after vitrectomy and phacovitrectomy for macular hole and epiretinal membrane
    Hamoudi, Hassan
    La Cour, Morten
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (06): : 942 - 947
  • [6] Comparison of Visual Outcomes after Combined Phacovitrectomy versus Sequential Vitrectomy and Phacoemulsification for Epiretinal Membrane
    Sabbagh, Mohammad Amr
    Lim, Jennifer I.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [7] Postoperative refractive error after phacovitrectomy for epiretinal membrane with and without macular oedema
    Frings, Andreas
    Dulz, Simon
    Skevas, Christos
    Stemplewitz, Birthe
    Linke, Stephan J.
    Richard, Gisbert
    Wagenfeld, Lars
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (07) : 1097 - 1104
  • [8] Postoperative refractive error after phacovitrectomy for epiretinal membrane with and without macular oedema
    Andreas Frings
    Simon Dulz
    Christos Skevas
    Birthe Stemplewitz
    Stephan J. Linke
    Gisbert Richard
    Lars Wagenfeld
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2015, 253 : 1097 - 1104
  • [9] Long-Term Reproducibility of Axial Length after Combined Phacovitrectomy in Macula-sparing Rhegmatogenous Retinal Detachment
    Kang, Tae-Seen
    Park, Hye-Jin
    Jo, Young-Joon
    Kim, Jung-Yeul
    SCIENTIFIC REPORTS, 2018, 8
  • [10] Long-Term Reproducibility of Axial Length after Combined Phacovitrectomy in Macula-sparing Rhegmatogenous Retinal Detachment
    Tae-Seen Kang
    Hye-Jin Park
    Young-Joon Jo
    Jung-Yeul Kim
    Scientific Reports, 8