Comparative Microstructural Analysis of Nongraphitic Carbons by Wide-Angle X-ray and Neutron Scattering

被引:21
|
作者
Pfaff, Torben [1 ]
Badaczewski, Felix M. [1 ]
Loeh, Marc O. [1 ,2 ]
Franz, Alexandra [3 ]
Hoffmann, Jens-Uwe [3 ]
Reehuis, Manfred [3 ]
Zeier, Wolfgang G. [1 ]
Smarsly, Bernd M. [1 ,4 ]
机构
[1] Justus Liebig Univ, Inst Phys Chem, Heinrich Buff Ring 17, D-35392 Giessen, Germany
[2] Schunk GmbH, Schunk Carbon Technol, D-35452 Heuchelheim, Germany
[3] Helmholtz Zentrum Berlin Mat & Energie, D-14109 Berlin, Germany
[4] Justus Liebig Univ, Ctr Mat Res LaMa, Heinrich Buff Ring 16, D-35392 Giessen, Germany
来源
JOURNAL OF PHYSICAL CHEMISTRY C | 2019年 / 123卷 / 33期
关键词
DIFFRACTION; PYROCARBONS; PROGRAM;
D O I
10.1021/acs.jpcc.9b03590
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Non-graphitic carbons (NGCs) represent the most abundant class of sp(2)-hybridized carbon, materials (coal char coal, activated carbon, etc.). These carbons consist of small graphene layer stacks possessing significant structural disorder in both the single graphene sheets and the stacking. In this study an advanced evaluation approach for wide-angle neutron scattering (WANS) was developed, based on the method introduced by Ruland and Smarsly in 2002. In particular, we elucidated if and how the enhanced WANS data quality and larger values of the modulus of the scattering vector s-range affect the accuracy and the values of the size and disorder parameters-being fitting parameters by themselves-in comparison to wide-angle X-ray scattering (WAXS), which is usually performed by laboratory equipment. We find a reasonable agreement for the parameters L-a and L-c, that is, the lateral dimension and stack height, within the error bars, whereas for the disorder parameters different results for WAXS and WANS were found, the origin of which is discussed. Thus, this study addresses the general issue of how reliably microstructural parameters can be determined from WAXS/WANS by fitting simulated WAXS and WANS curves, which are quality-impaired by added Gaussian noise at different levels and cut-off at different s-values. From this analysis, we estimated the minimal data quality required for a reliable NGC microstructural analysis based on WAXS/WANS. As an important finding, these simulations show that typical, standard WAXS laboratory setups are sufficient to provide reliable values for the most relevant structural parameters. Furthermore, pair-(d)istribution function (PDF) analyses were performed on WAXS data obtained from a synchrotron facility. Comparing PDF and WAXS/WANS fitting analysis suggests the presence of small highly ordered oligoaromatic domains embedded in the larger graphene sheets, questioning the classical view on the NGC microstructure.
引用
收藏
页码:20532 / 20546
页数:15
相关论文
共 50 条
  • [1] Small, high temperature, wide-angle furnace for wide-angle X-ray scattering
    Shang, Xiaoxia
    Huang, Weifeng
    Fan, Yueqian
    Wu, Haijuan
    Wang, Meijun
    Chang, Liping
    Li, Dongfeng
    Li, Zhihong
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2023, 51 (06) : 634 - 644
  • [2] Measurements and analysis of wide-angle X-ray thermal diffuse scattering
    Gibaud, A
    PHASE TRANSITIONS, 1998, 67 (01) : 65 - 100
  • [3] Small-angle X-ray scattering and wide-angle X-ray scattering experiments combined with thermal and spectroscopic analysis techniques
    Bras, W
    Ryan, AJ
    JOURNAL OF MOLECULAR STRUCTURE, 1996, 383 (1-3) : 309 - 314
  • [4] Wide-angle X-ray scattering for screening functional ligands
    Senior, K
    DRUG DISCOVERY TODAY, 2005, 10 (03) : 163 - 163
  • [5] Wide-angle X-ray scattering as a probe for insulin denaturation
    Elshemey, Wael M.
    Mohammad, Ibtesam A.
    Elsayed, Anwar A.
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2010, 46 (05) : 471 - 477
  • [6] Investigation of the Microstructure of Disordered, Non-graphitic Carbons by an Advanced Analysis Method for Wide-Angle X-ray Scattering
    Faber, Kristin
    Badaczewski, Felix
    Ruland, Wilhelm
    Smarsly, Bernd M.
    ZEITSCHRIFT FUR ANORGANISCHE UND ALLGEMEINE CHEMIE, 2014, 640 (15): : 3107 - 3117
  • [7] CarbX: a program for the evaluation of wide-angle X-ray scattering data of non-graphitic carbons
    Pfaff, Torben
    Simmermacher, Mats
    Smarsly, Bernd M.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2018, 51 : 219 - 229
  • [8] Time-resolved small-angle X-ray scattering combined with wide-angle X-ray scattering
    Bras, W
    Ryan, AJ
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1997, 30 (02) : 816 - 821
  • [9] Calibration and error analysis of an arc detector for wide-angle X-ray scattering (WAXS)
    Shang, Xiaoxia
    Chen, Rongchao
    Wu, Haijuan
    Fan, Yueqian
    Wang, Meijun
    Li, Zhihong
    Chang, Liping
    Chen, Jiangang
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2024, 52 (04) : 385 - 400
  • [10] Conversion of Natural Tannin to Hydrothermal and Graphene-Like Carbons Studied by Wide-Angle X-ray Scattering
    Jurkiewicz, Karolina
    Hawelek, Lukasz
    Balin, Katarzyna
    Szade, Jacek
    Braghiroli, Flavia L.
    Fierro, Vanessa
    Celzard, Alain
    Burian, Andrzej
    JOURNAL OF PHYSICAL CHEMISTRY A, 2015, 119 (32): : 8692 - 8701