Quality assurance of intensity-modulated radiotherapy

被引:31
|
作者
Low, DA [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
关键词
D O I
10.1053/srao.2002.33700
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Intensity-modulated radiation therapy (IMRT) requires the use of inverse treatment planning and nonuniform fluence beams delivered by a series of complex radiation portals. The quality assurance procedures for conventional three-dimensional conformal radiation therapy (3D-CRT) have been developed and are in worldwide clinical use, but the more complex nature of IMRT limits the application of much of the quality assurance (QA) procedures developed for IMRT. Although consensus has not yet been reached regarding which procedures will eventually become recommended by official organizations, the field is rapidly coming to agreement on a basic set of procedures. This manuscript describes some of the novel techniques recently developed for IMRT QA, both for the validation of the calculated dose distribution and for assuring that the dose distribution reaches its intended targets. Copyright 2002, Elsevier Science (USA). All rights reserved.
引用
下载
收藏
页码:219 / 228
页数:10
相关论文
共 50 条
  • [1] Quality assurance of intensity-modulated radiotherapy treatment planning: a dosimetric comparison
    Altaf, Saima
    Iqbal, Khalid
    Akram, Muhammad
    Buzdar, Saeed A.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (04) : 396 - 402
  • [2] Multicentre quality assurance of intensity-modulated radiotherapy planning: Beware the benchmarker
    Back, M.
    Oliver, L.
    Bromley, R.
    Eade, T.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2008, 52 (02): : 197 - 197
  • [3] Changes in Patterns of Intensity-modulated Radiotherapy Verification and Quality Assurance in the UK
    Abolaban, F.
    Zaman, S.
    Cashmore, J.
    Nisbet, A.
    Clark, C. H.
    CLINICAL ONCOLOGY, 2016, 28 (08) : E28 - E34
  • [4] Siemens multileaf collimator characterization and quality assurance approaches for intensity-modulated radiotherapy
    Bayouth, John E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S93 - S97
  • [5] Quality assurance of intensity-modulated radiation therapy
    Palta, Jatinder R.
    Li, Chihray
    Li, Jonathan G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S108 - S112
  • [6] Statistical process control (SPC) to optimize quality assurance in intensity-modulated radiotherapy (IMRT)
    Gerard, K.
    Marchesi, V.
    Grandhaye, JP.
    Franceries, X.
    Husson, F.
    Noel, A.
    Kafrouni, H.
    Aletti, P.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S97 - S97
  • [7] Quality assurance methods for intensity modulated radiotherapy
    Cakir, Aydin
    Bilge, Hatice
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2013, 28 (02): : 81 - 90
  • [8] COMMISSIONING AND QUALITY ASSURANCE OF INTENSITY-MODULATED ARC THERAPY
    Bedford, J.
    Warrington, A.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S25 - S25
  • [9] Intensity-modulated radiotherapy
    Leibel, SA
    Fuks, Z
    Zelefsky, MJ
    Wolden, SL
    Rosenzweig, KE
    Alektiar, KM
    Hunt, MA
    Yorke, ED
    Hong, LX
    Amols, HI
    Burman, CM
    Jackson, A
    Mageras, GS
    LoSasso, T
    Happersett, L
    Spirou, SV
    Chui, CS
    Ling, CC
    CANCER JOURNAL, 2002, 8 (02): : 164 - 176
  • [10] A UK-WIDE QUALITY ASSURANCE PROGRAMME FOR AN INTENSITY-MODULATED PARTIAL BREAST RADIOTHERAPY TRIAL
    Ciurlionis, L.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S447 - S447