Comparison of the Reliability of Four Different Movement Thresholds When Evaluating Vertical Jump Performance

被引:1
|
作者
Barefoot, Madeleine [1 ]
Lamont, Hugh [1 ]
Smith, J. Chadwick [1 ]
机构
[1] Coastal Carolina Univ, Dept Kinesiol, Neuromech Lab, Conway, SC 29526 USA
关键词
kinetics; kinematics; force platform; reliability; STRENGTH-MATCHED MALE; TIME;
D O I
10.3390/sports10120193
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Analyzing vertical jumps performed on a force plate can be useful for the strength and conditioning professional in managing neuromuscular fatigue. The purpose of this study was to compare different movement thresholds when analyzing countermovement (CJ) and squat jump (SJ) performance. Twenty-one college-aged participants (9 female, 12 male) performed five CJs and five SJs. Movement initiation was identified when the vertical ground reaction force (VGRF) deviated five standard deviations (5SD), four standard deviations, (4SD), 2.5% of system weight (2.5%SW), and 10% of system weight (10%SW) from their starting position. For CJs, movement was determined when the VGRF deviated either above or below these thresholds (5SDAB, 4SDAB, 2.5%SWAB, 10%SWAB) and was compared to when VGRF deviated below these thresholds (5SDB, 4SDB, 2.5%SWB, 10%SWB) in terms of peak force (Fmax), net impulse (netIMP), braking impulse (brIMP), propulsive impulse, jump height (JHT), peak power (Pmax), peak velocity (Vmax), and RSImod. For SJs, movement was determined when VGRF initially rose above these thresholds (5SD, 4SD, 2.5%SW, and 10%SW) for Fmax, netIMP, JHT, and Vmax. Significant differences were observed among several methods except for Fmax. However, these differences were small. All CJ measures demonstrated good-to-excellent relative reliability (ICC: 0.790-0.990) except for netIMP for 2.5%SWAB (ICC: 0.479). All methods demonstrated good absolute reliability as measured by percent coefficient of variation (CV%) except brIMP and RSImod. This may be due to instructions given to each jumper as well as skill level. For SJs, no differences in Fmax or netIMP were found across all methods. Small differences were seen for JHT, Pmax, and Vmax across several methods. All methods produced acceptable CV% (<10%) and excellent ICCs (0.900-0.990). However, some jumpers produced CV% that was greater than 10% when determining JHT for 5SD, 4SD, and 2.5%SW methods. This could be due to our method of obtaining system weight. Based on our findings, we recommend using the 10%SW method for assessing SJ performance on a force plate.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Reliability and Validity of Two Measures of Vertical Jump Performance Following Different Warm-ups
    Moneghan, Kathleen
    Fradkin, Andrea
    Smoliga, James
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 866 - 866
  • [2] Evaluating performance during maximum effort vertical jump landings
    [J]. Harry, John R. (john.harry@ttu.edu), 1600, Human Kinetics Publishers Inc. (34):
  • [3] Evaluating Performance During Maximum Effort Vertical Jump Landings
    Harry, John R.
    Barker, Leland A.
    Eggleston, Jeffrey D.
    Dufek, Janet S.
    [J]. JOURNAL OF APPLIED BIOMECHANICS, 2018, 34 (05) : 403 - 409
  • [4] The validity and reliability of an iPhone app for measuring vertical jump performance
    Balsalobre-Fernandez, Carlos
    Glaister, Mark
    Lockey, Richard Anthony
    [J]. JOURNAL OF SPORTS SCIENCES, 2015, 33 (15) : 1574 - 1579
  • [5] Reliability of Vertical Jump Performance evaluated with contact mat in elderly women
    Farias, Darlan L.
    Teixeira, Tatiane G.
    Madrid, Bibiano
    Pinho, Danilo
    Boullosa, Daniel A.
    Prestes, Jonato
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2013, 33 (04) : 288 - 292
  • [6] Validity and Reliability of a Virtual Reality Game in Evaluating the Projected Frontal Plane Knee Angle When Landing From a Drop Vertical Jump
    Mills, Kathryn
    Idris, Aula
    Pham, Thu-An
    Porte, John
    Wiggins, Mark
    Kavakli, Manolya
    [J]. JOURNAL OF SPORT REHABILITATION, 2018, 27 (04) : 1 - 5
  • [7] The effects of different attentional foci on horizontal and vertical jump performance
    Williams, Brian M.
    Hebert, Edward
    [J]. JOURNAL OF SPORT & EXERCISE PSYCHOLOGY, 2013, 35 : S57 - S57
  • [8] The Acute Effects of Different Squat Intensities on Vertical Jump Performance
    Hill, Andrew R.
    Laudermilk, Daniel L.
    Choi, Soon-Mi
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 641 - 641
  • [9] Comparison of Truncation Thresholds with Four Different Robust Scale Estimators
    Okatan, Murat
    [J]. 2018 26TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2018,
  • [10] Validity and reliability of “My Jump app” to assess vertical jump performance: a meta-analytic review
    Cebrail Gençoğlu
    Süleyman Ulupınar
    Serhat Özbay
    Murat Turan
    Buğra Çağatay Savaş
    Selim Asan
    İzzet İnce
    [J]. Scientific Reports, 13