Study on EEG source localization in frequency domain

被引:0
|
作者
Zheng, Xuyuan [1 ]
Wan, Baikun [1 ]
机构
[1] Tianjin Med Univ, Tianjin, Peoples R China
关键词
frequency domain; source localization; predominant frequency;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This article deals with a new approach based on predominant frequency that combines EEG source localization methods with standard frequency analysis of multi-electrode EEGs. First, we describe the theoretical methodology of the frequency domain source localization. Then, this new application is used as signal-processing technique on simulating EEG recordings obtained from both single dipole model and double dipole model. Finally, we show that the obtained results constitute a promising methodology to study the cerebral electrical activity.
引用
收藏
页码:5958 / 5961
页数:4
相关论文
共 50 条
  • [1] Sparse EEG source localization in frequency domain
    del Rocio Hernandez-Castanon, Viviana
    Le Cam, Steven
    Ranta, Radu
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 6428 - 6432
  • [2] EEG Dipole Source Localization in Hemispherical Harmonics Domain
    Giri, Amita
    Kumar, Lalan
    Gandhi, Tapan
    2018 ASIA-PACIFIC SIGNAL AND INFORMATION PROCESSING ASSOCIATION ANNUAL SUMMIT AND CONFERENCE (APSIPA ASC), 2018, : 679 - 684
  • [3] Time domain source localization (TDSI) based on ictal EEG recordings
    Zilberstain, A
    Neufeld, M
    Kipervasser, S
    Teicher, M
    Adi-Japha, E
    EPILEPSIA, 2004, 45 : 245 - 245
  • [4] Epileptic Source Localization Using High Frequency Interictal EEG Signals
    Chinmayi, R.
    Nair, Jayachandran G.
    Nath, Ghanshyam R.
    Jishnu, V
    2016 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND COMPUTING RESEARCH, 2016, : 776 - 779
  • [5] FREQUENCY-DOMAIN SOURCE LOCALIZATION SHOWS STATE-DEPENDENT DIAZEPAM EFFECTS IN 47-CHANNEL EEG
    MICHEL, CM
    PASCUALMARQUI, RD
    STRIK, WK
    KOENIG, T
    LEHMANN, D
    JOURNAL OF NEURAL TRANSMISSION-GENERAL SECTION, 1995, 99 (1-3) : 157 - 171
  • [6] Frequency domain EEG source localization of ictal epileptiform activity in patients with partial complex epilepsy of temporal lobe origin
    Lantz, G
    Michel, CM
    Seeck, M
    Blanke, O
    Landis, T
    Rosén, I
    CLINICAL NEUROPHYSIOLOGY, 1999, 110 (01) : 176 - 184
  • [7] A comparative study of localization approaches to EEG source imaging
    Yildiz, Gokcen
    Duru, A. Deniz
    Ademoglu, Ahmet
    2007 IEEE/NIH LIFE SCIENCE SYSTEMS AND APPLICATIONS WORKSHOP, 2007, : 156 - +
  • [8] DIAZEPAM AND SULPIRIDE EFFECTS ON FREQUENCY-DOMAIN EEG SOURCE LOCATIONS
    KINOSHITA, T
    MICHEL, CM
    YAGYU, T
    LEHMANN, D
    SAITO, M
    NEUROPSYCHOBIOLOGY, 1994, 30 (2-3) : 126 - 131
  • [9] Underdetermined source separation of EEG signals in the time-frequency domain
    Shan, Zeyong
    Swary, Jacob
    Aviyente, Selin
    2008 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING, VOLS 1-12, 2008, : 3637 - 3640
  • [10] EEG dipole source localization
    Cuffin, BN
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1998, 17 (05): : 118 - 122