Exergy optimization of cooling tower for HGSHP and HVAC applications

被引:43
|
作者
Singh, Kuljeet [1 ]
Das, Ranjan [1 ]
机构
[1] Indian Inst Technol Ropar, Dept Mech Engn, Nangal Rd, Rupnagar 140001, Punjab, India
关键词
HVAC; HGSHP; Exergy destruction; Box-Behnken design; Constrained optimization; MULTIOBJECTIVE OPTIMIZATION; SYSTEM OPTIMIZATION; PERFORMANCE; ALGORITHM;
D O I
10.1016/j.enconman.2017.01.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present work, a constrained inverse optimization method for building cooling applications is proposed to control the mechanical draft wet cooling tower by minimizing the exergy destruction and satisfying an imposed heat load under varying environmental conditions. The optimization problem is formulated considering the cooling dominated heating, ventilation and air conditioning (HVAC) and hybrid ground source heat pump (HGSHP). As per the requirement, new second degree correlations for the tower outlet parameters (water temperature, air dry and wet-bulb temperatures) with five inlet parameters (dry-bulb temperature, relative humidity, water inlet temperature, water and air mass flow rates) are developed. The Box-Behnken design response surface method is implemented for developing the correlations. Subsequently, the constrained optimization problem is solved using augmented Lagrangian genetic algorithm. This work further developed optimum inlet parameters operating curves for the HGSHP and the HVAC systems under varying environmental conditions aimed at minimizing the exergy destruction along with the fulfillment of the required heat load. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:418 / 430
页数:13
相关论文
共 50 条
  • [1] A simplified modeling of mechanical cooling tower for control and optimization of HVAC systems
    Jin, Guang-Yu
    Cai, Wen-Jian
    Lu, Lu
    Lee, Eng Lock
    Chiang, Andrew
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (02) : 355 - 365
  • [2] Principles of exergy analysis in HVAC and evaluation of evaporative cooling schemes
    Ren, CQ
    Li, NP
    Tang, GF
    [J]. BUILDING AND ENVIRONMENT, 2002, 37 (11) : 1045 - 1055
  • [3] An exergy analysis on the performance of a counterflow wet cooling tower
    Muangnoi, Thirapong
    Asvapoositkul, Wanchai
    Wongwises, Somchai
    [J]. APPLIED THERMAL ENGINEERING, 2007, 27 (5-6) : 910 - 917
  • [4] EXERGY ANALYSIS OFTHE CROSS CURRENT COOLING TOWER
    Rawabawale, Nandkumar
    Sapali, Shivalingappa
    [J]. JOURNAL OF THERMAL ENGINEERING, 2020, 6 (04): : 499 - 510
  • [5] Exergy Based Performance Analysis of a Shower Cooling Tower
    Qi, Xiaoni
    Liu, Yongqi
    Liu, Zhenyan
    [J]. STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2013, 59 (04): : 251 - 259
  • [6] Performance Study of an HVAC Counterflow Cooling Tower in a Humid Climate
    Abdalla, Kamal
    Fadi, Mansour
    Elsarrag, Esam
    [J]. ASHRAE TRANSACTIONS 2009, VOL 115, PT 1, 2009, 115 : 595 - +
  • [7] Subtleties in cooling tower optimization
    Ping, Seer
    Lipták, Béla
    [J]. Control, 2020, 33 (10): : 43 - 44
  • [8] Optimum Design and Operation of an HVAC Cooling Tower for Energy and Water Conservation
    Cutillas, Clemente Garcia
    Ramirez, Javier Ruiz
    Miralles, Manuel Lucas
    [J]. ENERGIES, 2017, 10 (03):
  • [9] Regression model of heat exchange efficiency of cooling tower in an HVAC system
    采暖通风与空调系统中冷却塔传热效率的回归模型
    [J]. Chen, Xi (bjchenxi@mail.tsinghua.edu.cn), 1801, Northeast University (33):
  • [10] Exergy analysis of psychrometric processes for HVAC&R applications
    Kanoglu, Mehmet
    Dincer, Ibrahim
    Rosen, Marc A.
    [J]. ASHRAE TRANSACTIONS 2007 VOL 113, PT 2, 2007, 113 : 172 - 180