Fire testing of high strength concrete filled steel columns

被引:0
|
作者
Patterson, NL [1 ]
Zhao, XL [1 ]
Wong, MB [1 ]
Ghojel, J [1 ]
Grundy, P [1 ]
机构
[1] Monash Univ, Dept Civil Engn, Melbourne, Vic 3004, Australia
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Over the past few decades, composite columns have become a popular component of the structural skeleton. One such composite column is manufactured by filling steel hollow section tubes with high strength concrete. The use of steel and concrete together in this configuration has many advantages. However the current technique of providing adequate fire resistance to this type of composite column is by external fire protection which significantly adds to the cost of construction. Monash University has conducted research on the feasibility of using high strength concrete filled steel columns without any external fire protection in which part of the column perimeter is directly exposed to the elevated temperature atmosphere. This is the first experimental study with this temperature exposure condition for these types of columns. Various composite column sections were used in the furnace tests to study their behaviour and performance. This paper reports some results obtained from this experimental study.
引用
收藏
页码:437 / 442
页数:6