Echocardiographic Changes in the Context of Metal-on-Metal Versus Nonmetal-on-Metal Total Hip Arthroplasty

被引:3
|
作者
Darrith, Brian [1 ]
Rahman, Tahsin M. [1 ,2 ]
Ananthasubramaniam, Karthikeyan [3 ]
Culvern, Chris [4 ]
Jacobs, Joshua J. [4 ]
Silverton, Craig D. [1 ]
机构
[1] Henry Ford Hosp, Dept Orthopaed Surg, 2799 West Grand Blvd,CFP 6, Detroit, MI 48202 USA
[2] Wayne State Univ, Sch Med, Detroit, MI USA
[3] Henry Ford Hosp, Dept Cardiol, Detroit, MI 48202 USA
[4] Rush Univ, Med Ctr, Dept Orthopaed Surg, Chicago, IL 60612 USA
来源
JOURNAL OF ARTHROPLASTY | 2020年 / 35卷 / 11期
关键词
metal-on-metal; cobalt; chromium; total hip arthroplasty; Profemur Z; cobalt cardiomyopathy; SYSTOLIC EXCURSION TAPSE; ARTHROPROSTHETIC COBALTISM; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; ION LEVELS; FOLLOW-UP; REPLACEMENT; REVISION; CARDIOMYOPATHY; TOXICITY;
D O I
10.1016/j.arth.2020.06.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The purpose of this study is to determine if there is a difference in echocardiographic results between patients with metal-on-metal (MoM) vs non-MoM total hip arthroplasty (THA) and to determine if a correlation exists between serum metal levels and echocardiographic outcomes. Methods: Seventy-five patients with the same modular THA enrolled in this prospective cohort study, and 49 had MoM bearings. All patients had serum cobalt, chromium, and titanium levels drawn at 2 study visits with a transthoracic echocardiogram at the second visit. Serum metal concentrations and echocardiographic parameters were compared with 2-way t-tests. Multiple linear regression analyses identified any significant predictors of echocardiographic outcomes. Results: Mean serum cobalt and chromium levels were significantly greater in the MoM group at both time-points (P<.001 and P<.05, respectively). Titanium levels were similar between groups (P>.05). MoM patients had significantly lower global longitudinal strain compared with the non-MoM group (18.4% vs 20.2%; P=.026). Serum cobalt concentration was found to be an independent predictor of tricuspid annular plane systolic excursion (P=.02). Conclusion: MoM THA bearings are associated with increased serum cobalt and chromium levels. Patients with MoM THAs had decreased global longitudinal strain, a measure of left ventricular function, but both groups remained within normal range. The clinical impact of the positive association between serum cobalt concentration and tricuspid annular plane systolic excursion, a marker of right ventricular function, deserves further study. These findings can reassure physicians and patients that metal-induced cardiomyopathy is not typical in the setting of MoM THA. Published by Elsevier Inc.
引用
收藏
页码:3230 / +
页数:10
相关论文
共 50 条
  • [1] Metal-on-Metal Total Hip Arthroplasty
    Kim, Raymond H.
    Dennis, Douglas A.
    Carothers, Joshua T.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (07): : 44 - 46
  • [2] Metal-on-Metal Total Hip Arthroplasty
    Malviya, Ajay
    Ramaskandhan, Jayasree
    Holland, James P.
    Lingard, Elizabeth A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (07): : 1675 - 1683
  • [3] Metal-on-metal versus metal-on-polyethylene bearings in total hip arthroplasty
    Naudie, D
    Roeder, CP
    Parvizi, J
    Berry, DJ
    Eggli, S
    Busato, A
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (07): : 35 - 41
  • [4] Hip resurfacing and metal-on-metal total hip arthroplasty
    Beverland, David E.
    Spencer, Robert F.
    [J]. HIP INTERNATIONAL, 2011, 21 (03) : 277 - 278
  • [5] Metal-on-metal total hip arthroplasty - The concerns
    MacDonald, SJ
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) : 86 - 93
  • [6] Metal-on-Metal Total Hip Arthroplasty: The Concerns
    MacDonald, S. J.
    [J]. BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2005, : 47 - 47
  • [7] Metal-on-metal articulation in total hip arthroplasty
    Marchetti, P.G.
    Binazzi, R.
    Vaccari, V.
    Manca, A.
    Rossi, R.
    Campagna, A.
    Magnani, M.
    Baldarelli, M.
    Pasini, E.
    [J]. Key Engineering Materials, 2001, 192-195 : 975 - 977
  • [8] Metal-on-metal articulation in total hip arthroplasty
    Marchetti, PG
    Binazzi, R
    Vaccari, V
    Manca, A
    Rossi, R
    Campagna, A
    Magnani, M
    Baldarelli, M
    Pasini, E
    [J]. BIOCERAMICS, 2000, 192-1 : 975 - 977
  • [9] The rationale for metal-on-metal total hip arthroplasty
    Cuckler, JM
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) : 132 - 136
  • [10] Painful metal-on-metal total hip arthroplasty
    Shahrdar, C
    Campbell, P
    Mirra, J
    Dorr, LD
    [J]. JOURNAL OF ARTHROPLASTY, 2006, 21 (02): : 289 - 293