A comprehensive geometric quality assurance framework for preclinical microirradiators

被引:4
|
作者
Anvari, Akbar [1 ]
Poirier, Yannick [1 ]
Sawant, Amit [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
关键词
EPID; geometric; image-guided radiotherapy; preclinical; small animal; RADIATION RESEARCH PLATFORM; VERIFICATION; PERFORMANCE; ACCURACY;
D O I
10.1002/mp.13387
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe mechanical and geometric accuracy of small animal image-guided radiotherapy (SA-IGRT) systems is critical and is affected by a number of system-related factors. Because of the small dimensions involved in preclinical radiotherapy research, such factors can individually and/or cumulatively contribute to significant errors in the small animal radiation research. In this study, we developed and implemented a comprehensive quality assurance (QA) framework for characterizing the mechanical and geometric constancy and accuracy of the small animal radiation research platform (SARRP) system. MethodsWe quantified the accuracy of gantry and stage rotation isocentricity and positional stage translations. We determined the accuracy and symmetry of field sizes formed by collimators. We evaluated collimator assembly system performance by characterization of collimator axis alignment along the beam axis during gantry rotation. Furthermore, we quantified the end-to-end precision and accuracy of image-guided delivery by examining the congruence of intended (e.g., imaging) and actual delivery (measured during experiment) isocenters. ResultsThe fine and broad beams showed different central axes. The center of the beam was offset toward the cathode (0.220.05mm) when switching the beam from a fine to a broad focus. Larger (custom-made) collimators were more symmetrically centered than smaller (standard) collimators. The field formed by a 1-mm circular collimator was found to deviate from the circular shape, measuring 1.55mm and 1.25mm in the X and Y directions, respectively. The 40-mm collimator showed a field that was 1.65 (4.13%) and 1.3 (3.25%) mm smaller than nominal values in the X and Y directions, respectively, and the 30-mm collimator field was smaller by 0.75mm (2.5%) in the X direction. Results showed that fields formed by other collimators were accurate in both directions and had 2% error. The size of the gantry rotation isocenter was 1.45 +/- 0.15mm. While the gantry rotated, lateral and longitudinal isocenter displacements ranged from 0 to -0.34 and -0.44 to 0.33mm, respectively. Maximum lateral and longitudinal displacements were found at obliques gantry angles of -135 degrees and 45 degrees, respectively. The stage translational accuracies were 0.015, 0.010, and 0mm in the X, Y, and Z directions, respectively. The size of the stage rotation runout was 2.73 +/- 0.3mm. Maximum displacements of the stage rotational axis were -0.38 (X direction) and -0.26 (Y direction)mm at stage angles of -45 degrees and -135 degrees, respectively. We found that displacements of intended and actual delivery isocenters were 0.24 +/- 0.10, 0.12 +/- 0.62, and 0.12 +/- 0.42mm in the X, Y, and Z directions, respectively. ConclusionWe used the SARRP built-in electronic portal imaging device (EPID) to perform most of the geometric QA tests, demonstrating the utility of the EPID for characterizing the geometric accuracy and precision of the SA-IGRT system. However, in principle, the methodology and tests developed here are applicable to any digital imaging detector available in SA-IGRT systems or film. The flexibility of film allows these tests to be adapted for QA of non-IGRT, cabinet irradiators, which make up many of preclinical small animal irradiators.
引用
收藏
页码:1840 / 1851
页数:12
相关论文
共 50 条
  • [1] A Comprehensive Framework for Quality Assurance in Clinical Trials
    El Gazzar, Omar
    Onken, Michael
    Eichelberg, Marco
    Hein, Andreas
    Kotter, Elmar
    [J]. MEDICAL IMAGING 2012: ADVANCED PACS-BASED IMAGING INFORMATICS AND THERAPEUTIC APPLICATIONS, 2012, 8319
  • [2] A comprehensive planning framework for selecting and customizing quality assurance techniques
    Elberzhager, Frank
    Denger, Christian
    [J]. SEAA 2007: 33RD EUROMICRO CONFERENCE ON SOFTWARE ENGINEERING AND ADVANCED APPLICATIONS, PROCEEDINGS, 2007, : 297 - +
  • [3] A Comprehensive Quality Assurance Program of Small Animal Irradiators for Preclinical Radiation Research
    Wang, Y. F.
    Lemus, O. Dona
    Wu, C. C.
    Wuu, C. S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E266 - E267
  • [4] Preclinical Image Guided Microirradiators: Concepts, Design and Implementation
    Izaguirre, E. W.
    Kassebaum, B. L.
    Birch, J.
    Su, I.
    Mutic, S.
    Parikh, P.
    Grigsby, P.
    Low, D.
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 2720 - +
  • [5] Comprehensive Quality Assurance Services
    [J]. Waste Disposal and Water Management in Australia, 1995, 22 (01):
  • [6] Towards Quality Assurance in MOOCs: A Comprehensive Review and Micro-Level Framework
    Sebbeq, Hanane
    El Faddouli, Nour-eddine
    [J]. INTERNATIONAL REVIEW OF RESEARCH IN OPEN AND DISTRIBUTED LEARNING, 2024, 25 (01): : 1 - 23
  • [7] A framework for quality assurance in teaching
    Goh, TN
    [J]. TOTAL QUALITY MANAGEMENT, 1996, 7 (02): : 183 - 188
  • [8] A framework for institutionalizing quality assurance
    Silimperi, DR
    Franco, LM
    Van Zanten, TV
    Macaulay, C
    [J]. INTERNATIONAL JOURNAL FOR QUALITY IN HEALTH CARE, 2002, 14 : 67 - 73
  • [9] The Echocardiography Quality Framework: a comprehensive, patient-centered approach to quality assurance and continuous service improvement
    Masani, Navroz
    [J]. ECHO RESEARCH AND PRACTICE, 2018, 5 (04): : G35 - G41
  • [10] EVALUATION OF THE LIMIT OF GEOMETRIC RESOLUTION FOR QUALITY ASSURANCE
    HAUS, AG
    GUEBERT, DK
    MEYER, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 136 (06) : 1276 - 1276