New Developments Are Improving Flexor Tendon Repair

被引:77
|
作者
Tang, Jin Bo [1 ]
机构
[1] Nantong Univ, Hand Surg Res Ctr, Dept Hand Surg, Affiliated Hosp, 20 West Temple Rd, Nantong 226001, Jiangsu, Peoples R China
关键词
EARLY ACTIVE MOBILIZATION; CORE SUTURE PURCHASE; A4; PULLEY; ZONES; OUTCOMES; STRENGTH; EXPERIENCE; MOTION; REHABILITATION; SURGEONS;
D O I
10.1097/PRS.0000000000004416
中图分类号
R61 [外科手术学];
学科分类号
摘要
New developments in primary tendon repair in recent decades include stronger core tendon repair techniques, judicious and adequate venting of critical pulleys, followed by a combination of passive and active digital flexion and extension. During repair, core sutures over the tendon should have sufficient suture purchase (no shorter than 0.7 to 1 cm) in each tendon end and must be sufficiently tensioned to resist loosening and gap formation between tendon ends. Slight or even modest bulkiness in the tendon substance at the repair site is not harmful, although marked bulkiness should always be avoided. To expose the tendon ends and reduce restriction to tendon gliding, the longest annular pulley in the fingers (i.e., the A2 pulley) can be vented partially with an incision over its distal or proximal sheath no longer than 1.5 to 2 cm; the annular pulley over the middle phalanx (i.e., the A4 pulley) can be vented entirely. Surgeons have not observed adverse effects on hand function after judicious and limited venting. The digital extension-flexion test to check the quality of the repair during surgery has become increasingly routine. A wide-awake surgical setting allows patient to actively move the digits. After surgery, surgeons and therapists protect patients with a short splint and flexible wrist positioning, and are now moving toward out-of-splint freer early active motion. Improved outcomes have been reported over the past decade with minimal or no rupture during postoperative active motion, along with lower rates of tenolysis.
引用
收藏
页码:1427 / 1437
页数:11
相关论文
共 50 条
  • [1] Improving Results of Flexor Tendon Repair and Rehabilitation
    Wong, Jason K. F.
    Peck, Fiona
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2014, 134 (06) : 913E - 925E
  • [2] Recent developments in flexor tendon repair techniques and factors influencing strength of the tendon repair
    Wu, Y. F.
    Tang, J. B.
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2014, 39 (01) : 6 - 19
  • [3] A NEW APPROACH TO FLEXOR TENDON REPAIR
    CALLAN, PP
    MORRISON, WA
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1994, 19B (04): : 513 - 516
  • [4] A NEW TECHNIQUE FOR FLEXOR TENDON REPAIR
    WEIR, RU
    SCOTT, TJ
    LEVINSOHN, DG
    MESKIN, BD
    GORDON, L
    [J]. CLINICAL RESEARCH, 1992, 40 (01): : A115 - A115
  • [5] Improving Outcomes in Tendon Repair: A Critical Look at the Evidence for Flexor Tendon Repair and Rehabilitation
    Khor, Wee S.
    Langer, Martin F.
    Wong, Richard
    Zhou, Rui
    Peck, Fiona
    Wong, Jason K. F.
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2016, 138 (06) : 1045E - 1058E
  • [6] REPAIR OF THE FLEXOR TENDON
    PIKE, WAJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1950, 32 (01): : 138 - 138
  • [7] The safety pin: A new technique for flexor tendon repair
    Tandon, S
    Callaghan, CG
    Juma, A
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2001, 108 (06) : 1830 - 1831
  • [8] Biomechanical assessment of a new type of flexor tendon repair
    Smith, AM
    Evans, DM
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2001, 26 (03): : 217 - 219
  • [9] INVITRO STUDIES OF A NEW METHOD OF FLEXOR TENDON REPAIR
    SAVAGE, R
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1985, 10B (02): : 135 - 141
  • [10] PATHOLOGY OF FLEXOR TENDON REPAIR
    MATTHEWS, P
    [J]. HAND, 1979, 11 (03): : 233 - 242