The presence of a specific genotype of Legionella pneumophila serogroup 1 in a hospital and municipal water distribution system over a 12-year period

被引:12
|
作者
Darelid, J
Bernander, S
Jacobson, K
Löfgren, S
机构
[1] Ryhov Hosp, Dept Infect Dis, S-55185 Jonkoping, Sweden
[2] Karolinska Univ Hosp, Dept Clin Microbiol, S-17176 Stockholm, Sweden
[3] Karolinska Inst, MTC, Ctr Microbiol & Tumor Biol, S-17176 Stockholm, Sweden
[4] Ryhov Hosp, Dept Clin Microbiol, S-55185 Jonkoping, Sweden
关键词
D O I
10.1080/00365540410020749
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
The genotypic distribution of Legionella pneumophila serogroup 1 was investigated in the water distribution system of a 450-bed Swedish hospital and the surrounding community. A single genotype identified by amplified fragment length polymorphism (AFLP) analysis, was found in all 34 hospital isolates and in 18 out of 20 community isolates over a 12-y surveillance period. All isolates were either monoclonal antibody subtypes Benidorm or Bellingham. In a geographical comparison, the hospital genotype was also identified in 2 out of 6 Swedish hospitals, both located within 100 km of the studied community. In all, 70 isolates originating from 7 Swedish communities clustered in 4 groups, each also containing 1 AFLP type as defined by the European Working Group on Legionella Infections (EWGLI). It was concluded that a single Legionella pneumophila serogroup 1 genotype may colonize a large water distribution system over a long period of time, and that certain clones seem to be widely spread in the environment. Results from molecular typing of isolates originating from a limited geographical area must, therefore, be interpreted cautiously in epidemiological investigations of Legionnaires' disease.
引用
收藏
页码:417 / 423
页数:7
相关论文
共 50 条
  • [1] Characterization and cloning of a 37.6-kb plasmid carried by Legionella pneumophila recovered from patients and hospital water over a 12-year period
    Mansfield, SD
    Marrie, TJ
    Bezanson, GS
    [J]. CANADIAN JOURNAL OF MICROBIOLOGY, 1997, 43 (02) : 193 - 197
  • [2] Prevalence of Legionella pneumophila serogroup 1 in water distribution systems in Izmir province of Turkey
    Uzel, A
    Uçar, F
    Hames-Kocabas, EE
    [J]. APMIS, 2005, 113 (10) : 664 - 669
  • [3] Nosocomial Legionella pneumophila serogroup 5 outbreak associated with persistent colonization of a hospital water system
    Perola, O
    Kauppinen, J
    Kusnetsov, J
    Heikkinen, J
    Jokinen, C
    Katila, ML
    [J]. APMIS, 2002, 110 (12) : 863 - 868
  • [4] Geostatistics - a tool applied to the distribution of Legionella pneumophila in a hospital water system
    Lagana, Pasqualina
    Moscato, Umberto
    Poscia, Andrea
    La Milia, Daniele Ignazio
    Boccia, Stefania
    Avventuroso, Emanuela
    Delia, Santi
    [J]. ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2015, 22 (04) : 655 - 660
  • [5] PULMONARY ANGIOGRAPHY IN A NONTEACHING HOSPITAL OVER A 12-YEAR PERIOD
    CUMPSTON, N
    [J]. MEDICAL JOURNAL OF AUSTRALIA, 1993, 158 (03) : 213 - 213
  • [6] PULMONARY ANGIOGRAPHY IN A NONTEACHING HOSPITAL OVER A 12-YEAR PERIOD
    BERNARD, SA
    JONES, BM
    STUCKEY, JG
    [J]. MEDICAL JOURNAL OF AUSTRALIA, 1992, 157 (09) : 589 - 592
  • [7] PULMONARY ANGIOGRAPHY IN A NONTEACHING HOSPITAL OVER A 12-YEAR PERIOD
    LARCOS, G
    FARLOW, DC
    GRUENEWALD, SM
    ANTICO, VF
    [J]. MEDICAL JOURNAL OF AUSTRALIA, 1993, 158 (05) : 363 - 363
  • [8] DISTRIBUTION OF LEGIONELLAE IN A HOSPITAL WATER-SYSTEM - PREVALENCE OF IMMUNOLOGICALLY AND GENETICALLY RELATED LEGIONELLA-PNEUMOPHILA SEROGROUP-6 ISOLATES
    OTT, M
    BENDER, L
    LUCK, PC
    MEYER, P
    HACKER, J
    [J]. FEMS MICROBIOLOGY LETTERS, 1992, 95 (2-3) : 201 - 206
  • [9] Fluctuation in Legionella pneumophila counts in cooling towers over a 1-year period
    Ragull, S.
    Montengro, R.
    Garcia-Nunez, M.
    Sanchez, I.
    Soler, A.
    Sopena, N.
    Pedro-Botet, M. L.
    Esteve, M.
    Sabria, M.
    [J]. LEGIONELLA: STATE OF THE ART 30 YEARS AFTER ITS RECOGNITION, 2006, : 436 - +
  • [10] Persistence of Legionella pneumophila in a hospital's water system:: A 13-year survey
    Rangel-Frausto, MS
    Rhomberg, P
    Hollis, RJ
    Pfaller, MA
    Wenzel, RP
    Helms, CM
    Herwaldt, LA
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1999, 20 (12): : 793 - 797