Exact presentation of multivariate calibration model as univariate calibration graph

被引:36
|
作者
Faber, NM [1 ]
机构
[1] Univ Utrecht, Dept Vet Anat & Physiol, NL-3508 TD Utrecht, Netherlands
关键词
multivariate calibration; net analyte signal; analytical figures of merit; calibration factor; multiway calibration; near-infrared;
D O I
10.1016/S0169-7439(99)00054-4
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A proof is given that a recently introduced univariate presentation of a multivariate calibration model is exact, i.e., there are no approximations involved. The proof is based on: (1) previously proposed definitions of multivariate net analyte signal and multivariate calibration factors (sensitivity in classical model and inverse sensitivity in inverse model) and (2) the geometrical property of the true regression vector in inverse multivariate calibration that it must be proportional to the true multivariate net analyte signal Vector of a particular sample. The extension of the proof to multiway calibration is briefly discussed. A practical example from near-infrared (NIR) spectroscopy is used to illustrate that the proposed univariate presentation may give more meaning to the term 'spectral overlap'. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:107 / 114
页数:8
相关论文
共 50 条
  • [1] Inferences in multivariate-univariate calibration problems
    Benton, D
    Krishnamoorthy, K
    Mathew, T
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 2003, 52 : 15 - 39
  • [2] Univariate and multivariate DMS calibration for a single analyte
    Szczurek, Andrzej
    Maciejewska, Monika
    Zajiczek, Zaneta
    [J]. 11TH CONFERENCE ON INTERDISCIPLINARY PROBLEMS IN ENVIRONMENTAL PROTECTION AND ENGINEERING (EKO-DOK 2019), 2019, 100
  • [3] A multivariate approach to combine univariate calibration information
    Liao, JJZ
    [J]. JOURNAL OF CHEMOMETRICS, 2001, 15 (10) : 789 - 794
  • [4] Portable EDXRF For Quantification Of Metals In Soils: Univariate Calibration Versus Multivariate Calibration
    Novacoski, Ezequiel J.
    dos Santos, Felipe R.
    Melquiades, Fabio L.
    [J]. XXXV BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2013, 1529 : 63 - 65
  • [5] AN EXACT CONFIDENCE REGION IN MULTIVARIATE CALIBRATION
    MATHEW, T
    KASALA, S
    [J]. ANNALS OF STATISTICS, 1994, 22 (01): : 94 - 105
  • [6] Model transfer in multivariate calibration
    Chu, XL
    Yuan, HF
    Lu, WZ
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2001, 21 (06) : 881 - 885
  • [7] Model transfer in multivariate calibration
    Chu, Xiao-Li
    Yuan, Hong-Fu
    Lu, Wan-Zhen
    [J]. Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2001, 21 (06):
  • [8] FROM UNIVARIATE TO MULTIVARIATE CALIBRATION: EXPERIENCES IN THE ANALYTICAL CHEMISTRY LABORATORY COURSES
    Saez, J.
    Kortazar, L.
    Izaguirre, J. K.
    Castro, K.
    Martinez, I.
    Fernandez, L.
    [J]. INTED2012: INTERNATIONAL TECHNOLOGY, EDUCATION AND DEVELOPMENT CONFERENCE, 2012, : 1546 - 1554
  • [9] Robust Probabilistic Multivariate Calibration Model
    Fang, Yi
    Jeong, Myong K.
    [J]. TECHNOMETRICS, 2008, 50 (03) : 305 - 316
  • [10] Detection limit estimator for multivariate calibration by an extension of the IUPAC recommendations for univariate methods
    Ostra, Miren
    Ubide, Carlos
    Vidal, Maider
    Zuriarrain, Juan