Achieving Accurate Compound Concentration in Cell-Based Screening: Validation of Acoustic Droplet Ejection Technology

被引:37
|
作者
Grant, Richard John [1 ]
Roberts, Karen [1 ]
Pointon, Carly [1 ]
Hodgson, Clare [1 ]
Womersley, Lynsey [1 ]
Jones, Darren Craig [1 ]
Tang, Eric [1 ]
机构
[1] AstraZeneca, Macclesfield SK10 4TG, Cheshire, England
关键词
acoustic droplet ejection; Echo; nanoliter dispensing; dose response; serial dilution; cell based; compound handling; noncontact;
D O I
10.1177/1087057109336588
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Compound handling is a fundamental and critical step in compound screening throughout the drug discovery process. Although most compound-handling processes within compound management facilities use 100% DMSO solvent, conventional methods of manual or robotic liquid-handling systems in screening workflows often perform dilutions in aqueous solutions to maintain solvent tolerance of the biological assay. However, the use of aqueous media in these applications can lead to suboptimal data quality due to compound carryover or precipitation during the dilution steps. In cell-based assays, this effect is worsened by the unpredictable physical characteristics of compounds and the low DMSO tolerance within the assay. In some cases, the conventional approaches using manual or automated liquid handling resulted in variable IC50 dose responses. This study examines the cause of this variability and evaluates the accuracy of screening data in these case studies. A number of liquid-handling options have been explored to address the issues and establish a generic compound-handling workflow to support cell-based screening across our screening functions. The authors discuss the validation of the Labcyte Echo reformatter as an effective noncontact solution for generic compound-handling applications against diverse compound classes using triple-quad liquid chromatography/mass spectrometry. The successful validation and implementation challenges of this technology for direct dosing onto cells in cell-based screening is discussed. (Journal of Biomolecular Screening 2009: 452-459)
引用
收藏
页码:452 / 459
页数:8
相关论文
共 50 条
  • [1] Acoustic droplet ejection facilitates cell-based high-throughput screenings using natural products
    Mackenzie, Thomas A.
    Tormo, Jose R.
    Cautain, Bastien
    Martinez, German
    Sanchez, Isabel
    Genilloud, Olga
    Vicente, Francisca
    Ramos, Maria C.
    SLAS TECHNOLOGY, 2024, 29 (03): : 100111
  • [2] Acoustic Droplet Ejection Technology and Its Application in High-Throughput RNA Interference Screening
    Nebane, N. Miranda
    Coric, Tatjana
    McKellip, Sara
    Woods, LaKeisha
    Sosa, Melinda
    Rasmussen, Lynn
    Bjornsti, Mary-Ann
    White, E. Lucile
    JALA, 2016, 21 (01): : 198 - 203
  • [3] Compound Transfer by Acoustic Droplet Ejection Promotes Quality and Efficiency in Ultra-High-Throughput Screening Campaigns
    Dawes, Timothy D.
    Turincio, Rebecca
    Jones, Steven W.
    Rodriguez, Richard A.
    Gadiagellan, Dhireshan
    Thana, Peter
    Clark, Kevin R.
    Gustafson, Amy E.
    Orren, Linda
    Liimatta, Marya
    Gross, Daniel P.
    Maurer, Till
    Beresini, Maureen H.
    JALA, 2016, 21 (01): : 64 - 75
  • [4] Cell-Based Drug Combination Screening with a Microfluidic Droplet Array System
    Du, Guan-Sheng
    Pan, Jian-Zhang
    Zhao, Shi-Ping
    Zhu, Ying
    den Toonder, Jaap M. J.
    Fang, Qun
    ANALYTICAL CHEMISTRY, 2013, 85 (14) : 6740 - 6747
  • [5] Identification of oxytetracycline as a chondrogenic compound using a cell-based screening system
    Hojo, Hironori
    Yano, Fumiko
    Ohba, Shinsuke
    Igawa, Kazuyo
    Nakajima, Keiji
    Komiyama, Yuske
    Kan, Akinori
    Ikeda, Toshiyuki
    Yonezawa, Takayuki
    Woo, Je-Tae
    Takato, Tsuyoshi
    Nakamura, Kozo
    Kawaguchi, Hiroshi
    Chung, Ung-il
    JOURNAL OF BONE AND MINERAL METABOLISM, 2010, 28 (06) : 627 - 633
  • [6] Identification of oxytetracycline as a chondrogenic compound using a cell-based screening system
    Hironori Hojo
    Fumiko Yano
    Shinsuke Ohba
    Kazuyo Igawa
    Keiji Nakajima
    Yuske Komiyama
    Akinori Kan
    Toshiyuki Ikeda
    Takayuki Yonezawa
    Je-Tae Woo
    Tsuyoshi Takato
    Kozo Nakamura
    Hiroshi Kawaguchi
    Ung-il Chung
    Journal of Bone and Mineral Metabolism, 2010, 28 : 627 - 633
  • [7] Cell-based screening and validation of human novel genes associated with cell viability
    Wang, Lan
    Gao, Xia
    Gao, Peng
    Deng, Weiwei
    Yu, Peng
    Ma, Jinjing
    Guo, Jinhai
    Wang, Xinyu
    Cheng, Hualing
    Zhang, Chenying
    Yu, Chuanfei
    Ma, Xi
    Lv, Bingfeng
    Lu, Yang
    Shi, Taiping
    Ma, Dalong
    JOURNAL OF BIOMOLECULAR SCREENING, 2006, 11 (04) : 369 - 376
  • [8] A Perfluoropolyether Microfluidic Device for Cell-Based Drug Screening with Accurate Quantitative Analysis
    Choi, Hyun Sun
    Ahn, Gwang-Noh
    Na, Gi-Su
    Cha, Hyung Joon
    Kim, Dong-Pyo
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2022, : 4577 - 4585
  • [9] A Perfluoropolyether Microfluidic Device for Cell-Based Drug Screening with Accurate Quantitative Analysis
    Choi, Hyun Sun
    Ahn, Gwang-Noh
    Na, Gi-Su
    Cha, Hyung Joon
    Kim, Dong-Pyo
    ACS Biomaterials Science and Engineering, 2022, 8 (10): : 4577 - 4585
  • [10] Development of a Cell-Based Assay Using a Split-Luciferase Reporter for Compound Screening
    Sato, Satoshi
    Ariga, Hiroyoshi
    Maita, Hiroshi
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2023, 46 (07) : 1010 - 1014