Bio-inspired piezoelectric artificial hair cell sensor fabricated by powder injection molding

被引:20
|
作者
Han, Jun Sae [1 ]
Oh, Keun Ha [1 ]
Moon, Won Kyu [1 ]
Kim, Kyungseop [2 ]
Joh, Cheeyoung [2 ]
Seo, Hee Seon [2 ]
Bollina, Ravi [3 ]
Park, Seong Jin [1 ]
机构
[1] Pohang Univ Sci & Engn POSTECH, Dept Mech Engn, Pohang 790784, South Korea
[2] Agcy Def Dev, Jinhae Shi, South Korea
[3] Mahindra Ecole Cent, Hyderabad 500043, Andhra Pradesh, India
关键词
powder injection molding; artificial hair cell; piezoelectricity; acoustic vector hydrophone; PMN-PZT; VECTOR HYDROPHONE;
D O I
10.1088/0964-1726/24/12/125025
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A piezoelectric artificial hair cell sensor was fabricated by the powder injection molding process in order to make an acoustic vector hydrophone. The entire process of powder injection molding was developed and optimized for PMN-PZT ceramic powder. The artificial hair cell sensor, which consists of high aspect ratio hair cell and three rectangular mechanoreceptors, was precisely fabricated through the developed powder injection molding process. The density and the dielectric property of the fabricated sensor shows 98% of the theoretical density and 85% of reference dielectric property of PMN-PZT ceramic powder. With regard to homogeneity, three rectangular mechanoreceptors have the same dimensions, with 3 mu m of tolerance with 8% of deviation of dielectric property. Packaged vector hydrophones measure the underwater acoustic signals from 500 to 800 Hz with - 212 dB of sensitivity. Directivity of vector hydrophone was acquired at 600 Hz as analyzing phase differences of electric signals.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A BIO-INSPIRED ELECTROMECHANICAL SYSTEM: ARTIFICIAL HAIR CELL
    Ahn, Kang-Hun
    [J]. ELECTRON TRANSPORT IN NANOSYSTEMS, 2008, : 351 - 359
  • [2] Bio-inspired mammalian hair-fabricated microfluidics
    Swaminathan, Swathi
    Harris, Thomas
    McClellan, Dan
    Cui, Yue
    [J]. MATERIALS LETTERS, 2013, 106 : 208 - 212
  • [3] Flow field sensing with bio-inspired artificial hair cell arrays
    Sarlo, Rodrigo
    Najem, Joseph S.
    Leo, Donald J.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 236 : 805 - 814
  • [4] Optimization of Bio-Inspired Piezoelectric Composite Hair Sensor-Mechanical Impedance Matching
    Tao, J.
    Yu, X.
    [J]. STRUCTURAL HEALTH MONITORING 2013, VOLS 1 AND 2, 2013, : 2157 - 2165
  • [5] Bio-inspired Nonlinear Control of Artificial Hair Cells
    Davaria, Sheyda
    Malladi, V. V. N. Sriram
    Tarazaga, Pablo A.
    [J]. STRUCTURAL HEALTH MONITORING, PHOTOGRAMMETRY & DIC, VOL 6, 2019, : 179 - 184
  • [6] A bio-inspired aquatic flow sensor using an artificial cell membrane
    Pinto, Preston A.
    Garrison, Kevin
    Leo, Donald J.
    Sarles, Stephen A.
    [J]. BIOINSPIRATION, BIOMIMETICS, AND BIOREPLICATION 2012, 2012, 8339
  • [7] Additive Manufacturing of an Insect Bio-inspired Hair Acoustic Sensor
    Martinelli, Samuele
    Reid, Andrew
    Domingo-Roca, Roger
    Windmill, James F. C.
    [J]. 2023 IEEE SENSORS, 2023,
  • [8] UV-NIL fabricated bio-inspired inlays for injection molding to influence the friction behavior of ceramic surfaces
    Muehlberger, M.
    Rohn, M.
    Danzberger, J.
    Sonntag, E.
    Rank, A.
    Schumm, L.
    Kirchner, R.
    Forsich, C.
    Gorb, S.
    Einwoegerer, B.
    Trappl, E.
    Heim, D.
    Schift, H.
    Bergmair, I.
    [J]. MICROELECTRONIC ENGINEERING, 2015, 141 : 140 - 144
  • [9] Bio-inspired directional sensor with piezoelectric microfiber and helical electrodes
    Tao, Junliang
    Yu, Xiong
    [J]. JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2016, 27 (13) : 1755 - 1766
  • [10] A Bio-Inspired Flow Sensor
    Yu, Xiong
    Tao, Junliang
    Berilla, Jim
    [J]. NANOSENSORS, BIOSENSORS, AND INFO-TECH SENSORS AND SYSTEMS 2010, 2010, 7646