Optimising the Validity of Shoulder Range of Motion Evaluation: A Comparative Study

被引:2
|
作者
Gliga, Alexandra-Camelia [1 ]
Neagu, Nicolae [1 ]
Szabo, Dan-Alexandru [1 ]
机构
[1] George Emil Palade Univ Med Pharm Sci & Technol, Targu Mures, Romania
关键词
goniometry; shoulder; proprioception; Kinesimeter; CONCURRENT VALIDITY; RELIABILITY; GONIOMETER; VALIDATION; ELBOW;
D O I
10.18662/brain/11.4Sup1/158
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
During the assessment process diachronically conceived in the initial, dynamic, and final stages, data recording is often performed by instrumental measurement using the goniometer. In Romania, the logistics equipment - hardware and software - has a very low or even absent incidence in the conceptual and applicative design of kinetic rehabilitation programmes. Some disadvantages of universal goniometry are revealed by relatively accurate measurements, given that the testing instrument may provide erroneous data when the specific rules are not followed. Moreover, the tester's interpretation of angular values may vary; therefore, in order to objectify and validate the specific assessment and evaluation, we propose a precise angular motion measurement device called Kinesimeter, assisted by specific Labview software designed at the Human Movement Science Discipline of "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures. Our purpose was to compare the results and interpret the differences arising from the use of two specific assessment methods for the shoulder range of motion. Thus, the values recorded by two physiotherapists using the manual goniometer were compared with the values recorded with the Kinesimeter. In order to validate the results, we calculated statistical parameters such as correlation and significance. We strongly believe that the proposed hardware and software device for measuring, controlling, and analysing shoulder movements can become a modern performing tool needed by each rehabilitation institution, having a dual role - investigative and monitoring of a rehabilitation programme - both extremely important, additional to current measurements with the goniometer.
引用
收藏
页码:101 / +
页数:12
相关论文
共 50 条
  • [1] Validity and reliability of POM-Checker in measuring shoulder range of motion Protocol for a single center comparative study
    Chu, Hongmin
    Joo, Seongsu
    Kim, Jinyoung
    Kim, Jae Kyoun
    Kim, Cheolhyun
    Seo, Jihye
    Kang, Dae Gill
    Lee, Ho Sub
    Sung, Kang-Keyng
    Lee, Sangkwan
    [J]. MEDICINE, 2018, 97 (25)
  • [2] Assessment of shoulder active range of motion in prone versus supine: a reliability and concurrent validity study
    Furness, James
    Johnstone, Scott
    Hing, Wayne
    Abbott, Allan
    Climstein, Mike
    [J]. PHYSIOTHERAPY THEORY AND PRACTICE, 2015, 31 (07) : 489 - 495
  • [3] Concurrent criterion validity of the iPodT in the measurement of shoulder range of motion: A cross-sectional study
    Tremblay, Pier-Thomas
    Albert, Felix
    Brochu, Frederic
    Tousignant-Laflamme, Yannick
    [J]. PHYSIOTHERAPY PRACTICE AND RESEARCH, 2020, 41 (01) : 23 - 34
  • [4] Validity and Reliability of POM-Checker for Measuring Shoulder Range of Motion in Healthy Participants: A Pilot Single-Center Comparative Study
    Chu, Hongmin
    Kim, Weonjin
    Joo, Seongsu
    Park, Eunsik
    Kim, Yeong Won
    Kim, Cheol-Hyun
    Lee, Sangkwan
    [J]. METHODS AND PROTOCOLS, 2023, 6 (06)
  • [5] RELIABILITYAND VALIDITY OF THE HALO DIGITAL GONIOMETER FOR SHOULDER RANGE OF MOTION IN HEALTHY SUBJECTS
    Correll, Sarah
    Field, Jennifer
    Hutchinson, Heather
    Mickevicius, Gabby
    Fitzsimmons, Amber
    Smoot, Betty
    [J]. INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2018, 13 (04): : 707 - 714
  • [6] Comparative accuracy of a shoulder range motion measurement sensor and Vicon 3D motion capture for shoulder abduction in frozen shoulder
    Park, Chanhee
    An, Yeongsang
    Yoon, Hyunsik
    Park, Ilbong
    Kim, Kyoungtae
    Kim, Chungyoo
    Cha, Youngjoo
    [J]. TECHNOLOGY AND HEALTH CARE, 2022, 30 : S251 - S257
  • [7] Validity of an Alternate Hand Behind Back Shoulder Range of Motion Measurement in Patients With Shoulder Pain and Movement Dysfunction
    Satpute, Kiran H.
    Hall, Toby
    Adanani, Aditi
    [J]. JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2018, 41 (03) : 242 - 251
  • [8] Investigation of the Impact of a Passive Shoulder Exoskeleton on the Shoulder Range of Motion: A Preliminary Study
    Ma, Tiejun
    Jonathan, Erik
    Xiong, Shuping
    [J]. DIGITAL HUMAN MODELING AND APPLICATIONS IN HEALTH, SAFETY, ERGONOMICS AND RISK MANAGEMENT, PT I, DHM 2024, 2024, 14709 : 219 - 230
  • [9] Shoulder Pain - Range of Motion
    Messenger, Nicole
    Estes, Kelly
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 486 - 486
  • [10] The concurrent validity and reliability of virtual reality to measure shoulder flexion and scaption range of motion
    Dejaco, Beate
    de Jong, Lex D.
    van Goor, Harry
    Staal, J. Bart
    Stolwijk, Niki
    Lewis, Jeremy
    [J]. PHYSIOTHERAPY, 2023, 120 : 95 - 102