Analysis of the systematic force-transmission error of the magnetic-suspension coupling in single-sinker densimeters and commercial gravimetric sorption analyzers

被引:30
|
作者
Kleinrahm, Reiner [1 ]
Yang, Xiaoxian [2 ]
McLinden, Mark O. [3 ]
Richter, Markus [4 ]
机构
[1] Ruhr Univ Bochum, Thermodynam, D-44780 Bochum, Germany
[2] Univ Western Australia, Fluid Sci & Resources Div, Crawley, WA 6009, Australia
[3] NIST, Appl Chem & Mat Div, 325 Broadway, Boulder, CO 80305 USA
[4] Tech Univ Chemnitz, Appl Thermodynam, D-09107 Chemnitz, Germany
关键词
Gravimetric sorption analyzer; Single-sinker densimeter; Force-transmission error; Magnetic-suspension coupling; Tandem-sinker densimeter; EQUATION-OF-STATE; ACCURATE DENSITY-MEASUREMENTS; CARBON-DIOXIDE; THERMODYNAMIC PROPERTIES; ADSORPTION EQUILIBRIUM; TEMPERATURE-RANGE; BINARY-MIXTURES; FLUID REGION; MELTING LINE; PRESSURES;
D O I
10.1007/s10450-019-00071-z
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Here we present an analysis of the force-transmission error for a commercial gravimetric sorption analyzer that applies equally to single-sinker densimeters. Gravimetric sorption analyzers are commonly used for the investigation of gas adsorption on porous materials (e.g., zeolites) with a simultaneous density measurement of the sample gas. The key component of the instrument is a magnetic-suspension coupling; this coupling transmits, without contact, the weight of the "density sinker" and of the sample container with the porous sample (which are both inside a pressurized measuring cell) to a balance at ambient pressure. However, since neither the coupling housing nor the sample gas are magnetically neutral, a small, systematic force-transmission error (FTE) occurs. For the correction of this FTE, an empirical correction model was developed. We show that the FTE can be subdivided into two parts: an apparatus contribution, and a fluid contribution. In the current paper we describe the effect of the FTE on the accuracy of the density measurements; the effect of the FTE on the accuracy of sorption measurements on porous and non-porous materials will be presented in a companion paper. The magnitude of the FTE in case of density measurement is shown by comparing the results of density measurements of four pure gases with values calculated from reference equations of state. The apparatus contribution of the FTE is typically (0.23 kg m(-3) + 50 x 10(-6).rho(fluid)), and the fluid contribution can reach values up to 500 x 10(-6).rho(fluid) for diamagnetic fluids; for oxygen-containing gas mixtures it can be much greater.
引用
收藏
页码:717 / 735
页数:19
相关论文
共 6 条
  • [1] Analysis of the systematic force-transmission error of the magnetic-suspension coupling in single-sinker densimeters and commercial gravimetric sorption analyzers
    Reiner Kleinrahm
    Xiaoxian Yang
    Mark O. McLinden
    Markus Richter
    Adsorption, 2019, 25 : 717 - 735
  • [2] Force Transmission Error Analysis for a High-Pressure Single-Sinker Magnetic Suspension Densimeter
    Cristancho, Diego E.
    Mantilla, Ivan D.
    Ejaz, Saquib
    Hall, Kenneth R.
    Iglesias-Silva, Gustavo A.
    Atilhan, Mert
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2010, 31 (4-5) : 698 - 709
  • [3] Force Transmission Error Analysis for a High-Pressure Single-Sinker Magnetic Suspension Densimeter
    Diego E. Cristancho
    Ivan D. Mantilla
    Saquib Ejaz
    Kenneth R. Hall
    Gustavo A. Iglesias-Silva
    Mert Atilhan
    International Journal of Thermophysics, 2010, 31 : 698 - 709
  • [4] Uncertainty analysis of adsorption measurements using commercial gravimetric sorption analyzers with simultaneous density measurement based on a magnetic-suspension balance
    Xiaoxian Yang
    Reiner Kleinrahm
    Mark O. McLinden
    Markus Richter
    Adsorption, 2020, 26 : 645 - 659
  • [5] Uncertainty analysis of adsorption measurements using commercial gravimetric sorption analyzers with simultaneous density measurement based on a magnetic-suspension balance
    Yang, Xiaoxian
    Kleinrahm, Reiner
    McLinden, Mark O.
    Richter, Markus
    ADSORPTION-JOURNAL OF THE INTERNATIONAL ADSORPTION SOCIETY, 2020, 26 (04): : 645 - 659
  • [6] Determination of the force transmission error in a single-sinker magnetic suspension densimeter due to the fluid-specific effect and its correction for use with gas mixtures containing oxygen
    Lozano-Martin, Daniel
    Mondejar, Maria E.
    Segovia, Jose J.
    Chamorro, Cesar R.
    MEASUREMENT, 2020, 151