Background: The Royal College of Pathologists of Australasia Quality Assurance Programs (RCPAQAP) offers a comprehensive range of External Quality Assurance programs for all disciplines of pathology and is committed to delivering programs to advance outcomes in patient care and promote excellence in laboratory diagnostic and technical proficiency. Proficiency testing in cytopreparatory techniques became available for formal enrolment in 2018. The 2019 technical program focused on the demonstration of a laboratory to troubleshoot problems encountered during staining and processing. The exercise provided a peer comparison of a laboratory's ability to (1) identify the problem viewed from a digital image and (2) describe the troubleshooting steps to rectify the problem using assessment guidelines. Methods: Ten troubleshooting exercises including whole-slide z-stacked virtual images, a reference slide, and an online Result Entry questionnaire were provided. Common staining and processing problems were demonstrated in these exercises. Multiple-choice responses were made available to participants for each case with 1 response requiring submission. Participants were then allowed free text to describe how they would rectify the problem. Results: Of the 72 participants who participated, 62 participants (86%) achieved a satisfactory assessment, 6 participants (8%) received a borderline assessment, and 4 participants (6%) received an unsatisfactory assessment. The average mark obtained was 32.7 out of a total of 45 marks, which equates to a satisfactory assessment. The highest mark obtained for this survey was 42.5. Conclusions: Quality cytopathology preparatory techniques are integral to mitigating the risk of diagnostic error. The digital pathology platform allowed homogeneity of samples for all participants and appeared to be a satisfactory mode for demonstrating the technical problems to participants. Laboratories participating in this survey showed good performance in identifying processing and staining problems on virtual images and working through the troubleshooting steps. The exercise also identified a method for troubleshooting formalin vapour-affected slides using citrate buffer which may be useful for laboratories following in-house validation.
引用
收藏
页码:597 / 606
页数:10
相关论文
共 10 条
  • [1] Rapid On-Site Evaluation Technical Exercise Using Digital Pathology: Peer Comparison in an External Quality Assurance Setting
    Greaves, Janelle
    Pagliuso, Julia
    Ross, Jennifer
    Badrick, Tony
    [J]. ACTA CYTOLOGICA, 2022, 66 (03) : 235 - 243
  • [2] Evaluation of cryoprotein investigation using a digital external quality assurance scheme
    Patel, Dina
    Sargur, Ravishankar
    Sheldon, Joanna
    Wheeler, Rachel D.
    Stanley, Carol
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2024, 61 (05) : 347 - 355
  • [3] The Comparison of Pre-digital and Post-digital Surgical Pathology Quality Assurance Metrics at a Large Academic Center
    Cevik, Lokman
    Satturwar, Swati
    Parwani, Anil
    Li, Zaibo
    Kellough, David
    Suarez, Adrian
    Lujan, Giovanni
    [J]. LABORATORY INVESTIGATION, 2023, 103 (03) : S1700 - S1701
  • [4] A Comparison of Cytotoxicity Tests and the Validation of Results by Using Samples from an External Quality Assurance Scheme
    Irving, Jacquelyn
    West, Guy
    Zuvela, Emily
    Matson, Phillip
    Harrison, Keith
    [J]. AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2010, 50 : 6 - 6
  • [5] Digital vs traditional: Are diagnostic accuracy rates similar for glass slides vs whole slide images in a non-gynaecological external quality assurance setting?
    Ross, J.
    Greaves, J.
    Earls, P.
    Shulruf, B.
    Van Es, S. L.
    [J]. CYTOPATHOLOGY, 2018, 29 (04) : 326 - 334
  • [6] A comparison of perceived diagnostic image quality in direct digital panoramic images between standard and advanced external GOP image processing
    Svenson, Bjorn
    Bath, Magnus
    Karlsson, Reet
    Persson, Bo
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 2019, 77 (08) : 560 - 565
  • [7] Comparison of PCR and electrospray-ionization mass spectrometry (ESI-MS) with species-specific diagnostic algorithms during a biodefense external quality assurance exercise
    Thoma, B. R.
    Knoop, D.
    Hartmann, A.
    Tiemann, C.
    Zoeller, L.
    Hinz, C.
    Jacob, D.
    Grunow, R.
    Schmoldt, S.
    [J]. INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2012, 302 : 9 - 10
  • [8] A peer comparison program for the quality assurance of HPV DNA detection using the digene hybrid capture II/surepath method shows excellent analytic interlaboratory correlation
    Kuebler, D.
    Illingworth, A.
    Blenc, A.
    Wilbur, D.
    [J]. ACTA CYTOLOGICA, 2007, 51 (02) : 280 - 280
  • [9] A peer comparison program for the quality assurance of human papillomavirus DNA detection using the digene hybrid capture II/Surepath method shows excellent analytic interlaboratory correlation
    Kuebler, Diane L.
    Illingworth, Andrea
    Blenc, Ann Marie
    Wilbur, David C.
    [J]. CANCER CYTOPATHOLOGY, 2007, 111 (05): : 339 - 343
  • [10] Note: Development of an external quality assurance scheme for the detection and enumeration of Pseudomonas aeruginosa from water and comparison of results using modified King's A broth and a commercial agar
    Place, BM
    Tillett, HE
    Lightfoot, NF
    [J]. JOURNAL OF APPLIED BACTERIOLOGY, 1996, 80 (06): : 682 - 686