Cross-sectional Comparison of Insulation Degradation Mechanisms and Lifetime Evaluation of Power Transmission Equipment

被引:19
|
作者
Shirasaka, Yukiyasu [1 ]
Murase, Hiroshi [2 ]
Okabe, Shigemitsu [3 ]
Okubo, Hitoshi [4 ]
机构
[1] Japan AE Power Syst Corp, Transformer Design Dept, Hitachi, Ibaraki 3168501, Japan
[2] Aichi Inst Technol, Dept Elect & Elect Engn, Toyota 4700392, Japan
[3] Tokyo Elect Power Co Ltd, High Voltage & Insulat Grp, Tsurumi Ku, Yokohama, Kanagawa 2308510, Japan
[4] Nagoya Univ, Dept Elect Engn & Comp Sci, Chikusa Ku, Nagoya, Aichi 4648603, Japan
关键词
Power transmission equipment; insulation degradation; lifetime evaluation; cross-sectional comparison; APPARATUS;
D O I
10.1109/TDEI.2009.4815192
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As the deregulation of the electric power industry moves forward, there is an increasing need for cost cutting and it is becoming exceedingly important to keep track of the residual life and identify the timing of replacement for power transmission equipment that has aged for several tens of years in the field. This paper, taking up the theme of "insulation degradation phenomena and lifetime evaluation for power transmission equipment", conducted cross-sectional comparison of different types of equipment although this kind of evaluation was made independently for these equipment types so far. This paper covered six types of equipment: gas insulated switchgear (GIS), gas insulated transformers, oil filled (OF) transformers, OF cables, crosslinked polyethylene (XLPE) cables, and power capacitors. As a result of examining the characteristics such as electric, thermal, mechanical, and hygroscopic degradations, each of these equipment types was found to have distinctive Voltage-time (V-t) and Voltage-number (V-N) characteristics, which sometimes greatly varied from those of others. Since thermal degradation is dominant for gas insulated transformers and oil filled transformers, their lifetimes depend on the reduction of mechanical strengths of Polyethylene Terephthalate (PET) or insulating paper. Therefore, it is effective to diagnose decomposition products such as CO, CO(2) and furfural generated in the thermal degradation mechanism. On the other hand, the influence of electric degradation has more significant impact on the other equipment types except OF cables. Such GIS components as epoxy spacers, XLPE cables, and power capacitors for which long-term ac voltages are dominant, are commonly characterized by the long-term V-t characteristics with a large gradient (small n-value). In terms of insulation structures, there is a possibility of reducing the degree of degradation by improving solids or the interface between solids and electrodes.
引用
收藏
页码:560 / 573
页数:14
相关论文
共 50 条
  • [1] EVALUATION OF INSULATION LIFETIME OF CABLES FOR POWER AND CONTROL SYSTEMS IN MINING ELECTRICAL EQUIPMENT
    Leonov, Andrey P.
    Soldatenko, Tatyana M.
    [J]. BULLETIN OF THE TOMSK POLYTECHNIC UNIVERSITY-GEO ASSETS ENGINEERING, 2022, 333 (01): : 113 - 120
  • [2] Pollution Measurement of External Insulation of Power Transmission and Transformation Equipment
    Wei, Wang Xin
    Hong, Liu
    Hua, Yu
    [J]. PROCEEDINGS OF 2020 IEEE 4TH INFORMATION TECHNOLOGY, NETWORKING, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (ITNEC 2020), 2020, : 2633 - 2637
  • [3] Insulation Evaluation of Capacitive Equipment by Power Loss Density
    Du, Lin
    Ran, Liman
    Li, Jian
    Wang, Feipeng
    Yang, Feng
    Wang, Disheng
    Jiang, Haibo
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE 2016 CONFERENCE ON DIAGNOSTICS IN ELECTRICAL ENGINEERING (DIAGNOSTIKA), 2016, : 119 - 121
  • [4] THE KINETICS AND MECHANISMS OF DEGRADATION OF CELLULOSIC INSULATION IN POWER TRANSFORMERS
    EMSLEY, AM
    [J]. POLYMER DEGRADATION AND STABILITY, 1994, 44 (03) : 343 - 349
  • [5] Serological Measures of Malaria Transmission in Haiti: Comparison of Longitudinal and Cross-Sectional Methods
    Arnold, Benjamin F.
    Priest, Jeffrey W.
    Hamlin, Katy L.
    Moss, Delynn M.
    Colford, John M., Jr.
    Lammie, Patrick J.
    [J]. PLOS ONE, 2014, 9 (04):
  • [6] CROSS-SECTIONAL ESTIMATE OF LOGGING EQUIPMENT RESALE VALUES
    CUBBAGE, FW
    BURGESS, JA
    STOKES, BJ
    [J]. FOREST PRODUCTS JOURNAL, 1991, 41 (10) : 16 - 22
  • [7] Observations of nanoindents via cross-sectional transmission electron microscopy: a survey of deformation mechanisms
    Lloyd, SJ
    Castellero, A
    Giuliani, F
    Long, Y
    McLaughlin, KK
    Molina-Aldareguia, JM
    Stelmashenko, NA
    Vandeperre, LJ
    Clegg, WJ
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2005, 461 (2060): : 2521 - 2543
  • [8] DETERMINATION OF CROSS-SECTIONAL ANATOMY BY TRANSMISSION SCANNING
    THIEME, GA
    HENDEE, WR
    CARSON, PL
    IBBOTT, GS
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1974, 19 (02): : 238 - 238
  • [9] Comparison of methods of recognition and classification of insulation defects of power equipment
    Kluge, Pawel
    Starzynski, Jacek
    [J]. PROCEEDINGS OF 2020 IEEE 21ST INTERNATIONAL CONFERENCE ON COMPUTATIONAL PROBLEMS OF ELECTRICAL ENGINEERING (CPEE), 2020,
  • [10] A Cross-Sectional Comparison of Computing Education
    Jesus, Salvador
    Martinez, Gutierrez
    Hart, Delbert
    [J]. 2016 INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE & COMPUTATIONAL INTELLIGENCE (CSCI), 2016, : 392 - 397