Assessment of Scoliosis Using 3-D Ultrasound Volume Projection Imaging with Automatic Spine Curvature Detection

被引:10
|
作者
Zhou, Guang-Quan [1 ]
Zheng, Yong-Ping [1 ]
机构
[1] Hong Kong Polytech Univ, Interdisciplinary Div Biomed Engn, Hong Kong, Hong Kong, Peoples R China
关键词
scoliosis; freehand 3-D ultrasound; volume projection imaging; ADOLESCENT IDIOPATHIC SCOLIOSIS; RADIOGRAPHS; CANCER; SYSTEM;
D O I
10.1109/ULTSYM.2015.045
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
X-ray imaging is a gold standard to diagnose scoliosis, a medical condition defined as lateral spine curvature > 10 degrees. However, radiation hazard restricts its application. 3-D ultrasound imaging shows potential for radiation-free scoliosis assessment. Recently, ultrasound volume projection imaging (VPI) was reported to provide a coronal view of spine for manual measurement of spine curvature. An automatic method for processing VPI images is now very much desired to avoid using tedious and subjective manual procedures, especially for scoliosis mass screening. In this paper, we reported an automatic method to quantitatively determine the spine curvature using the spine column profile, represented by the darkest region along the midline of VPI image. The method started with image enhancement using histogram equalization, and identified the points by locating the darkest points row by row in the enhanced image, followed by a polynomial curve fitting to the detected points. The spine curvature angle was finally calculated according to the inflection points on the curve. The performance was tested on the VPI images obtained from 36 subjects (Age: 30.1 +/- 14.5) with different spine curvatures. The curvatures obtained using the automatic method had a significant correlation with those by the manual method (r = 0.92; p < 0.001). The proposed automatic method is capable of measuring the spine curvature on the VPI images, thus greatly facilitating the use of 3-D ultrasound for scoliosis assessment.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Automatic Assessment of Ultrasound Curvature Angle for Scoliosis Detection Using 3-D Ultrasound Volume Projection Imaging
    Banerjee, Sunetra
    Huang, Zixun
    Lyu, Juan
    Leung, Frank H. F.
    Lee, Timothy
    Yang, De
    Zheng, Yongping
    McAviney, Jeb
    Ling, Sai Ho
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (05): : 647 - 660
  • [2] Automatic Measurement of Spine Curvature on 3-D Ultrasound Volume Projection Image With Phase Features
    Zhou, Guang-Quan
    Jiang, Wei-Wei
    Lai, Ka-Lee
    Zheng, Yong-Ping
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (06) : 1250 - 1262
  • [3] A fast 3-D ultrasound projection imaging method for scoliosis assessment
    Jiang, Wei-wei
    Zhou, Guang-quan
    Lai, Ka-Lee
    Hu, Song-yu
    Gao, Qing-yu
    Wang, Xiao-yan
    Zheng, Yong-ping
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2019, 16 (03) : 1067 - 1081
  • [4] Quantitative Evaluation of Spinal Coronal Curvature for Scoliosis Using a Fast 3-D Ultrasound Projection Imaging Method
    Jiang, W. W.
    Zhou, G. Q.
    Lai, K. L.
    Zheng, Y. P.
    INTERNATIONAL CONFERENCE FOR INNOVATION IN BIOMEDICAL ENGINEERING AND LIFE SCIENCES, ICIBEL2015, 2016, 56 : 313 - 317
  • [5] Ultrasound Volume Projection Imaging for Assessment of Scoliosis
    Cheung, Chung-Wai James
    Zhou, Guang-Quan
    Law, Siu-Yin
    Mak, Tak-Man
    Lai, Ka-Lee
    Zheng, Yong-Ping
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (08) : 1760 - 1768
  • [6] Development of Automatic Assessment Framework for Spine Deformity Using Freehand 3-D Ultrasound Imaging System
    Chen, Hongbo
    Qian, Liyue
    Gao, Yuchong
    Zhao, Jianhao
    Tang, Yiwen
    Li, Jiawen
    Le, Lawrence H.
    Lou, Edmond
    Zheng, Rui
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (03) : 408 - 422
  • [7] Quantification of thyroid volume using 3-D ultrasound imaging
    Kollorz, Eva N. K.
    Hahn, Dieter A.
    Linke, Rainer
    Goecke, Tamme W.
    Hornegger, Joachim
    Kuwert, Torsten
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (04) : 457 - 466
  • [8] Ultrasound Sagittal Projection Imaging for the Assessment of Scoliosis
    Li, Dong-Sheng
    Zhou, Guang-Quan
    He, Yi-Kang
    Zhou, Ping
    He, Si-Yuan
    Zheng, Yong-Ping
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [9] 3-D Perfusion Imaging Using Principal Curvature Detection Rendering
    Tremblay-Darveau, Charles
    Sheeran, Paul S.
    Vu, Cindy Kim
    Williams, Ross
    Bruce, Matthew
    Burns, Peter N.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (12) : 2286 - 2295
  • [10] Automatic Segmentation of 3D Ultrasound Spine Curvature Using Convolutional Neural Network
    Banerjee, Sunetra
    Ling, Sai Ho
    Lyu, Juan
    Su, Steven
    Zheng, Yong-Ping
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2039 - 2042