Quantification of left ventricular volumes using three-dimensional echocardiographic speckle tracking: comparison with MRI

被引:191
|
作者
Nesser, Hans-Joachim [2 ]
Mor-Avi, Victor [1 ]
Gorissen, Willem [3 ]
Weinert, Lynn [1 ]
Steringer-Mascherbauer, Regina [2 ]
Niel, Johannes [2 ]
Sugeng, Lissa [1 ]
Lang, Roberto M. [1 ]
机构
[1] Univ Chicago, Chicago, IL 60637 USA
[2] Publ Hosp Elisabethinen, Linz, Austria
[3] Toshiba Med Syst, Zoetermeer, Netherlands
关键词
Echocardiography; Magnetic resonance imaging; Left ventricle; CARDIAC RESYNCHRONIZATION THERAPY; AGE-RELATED-CHANGES; RADIAL STRAIN; MYOCARDIAL-INFARCTION; LONGITUDINAL STRAIN; DILATED CARDIOMYOPATHY; EJECTION FRACTION; TISSUE DOPPLER; HEART-FAILURE; DYSSYNCHRONY;
D O I
10.1093/eurheartj/ehp187
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although the utility of two-dimensional (2D) speckle tracking echocardiography (STE) to quantify left ventricular (LV) volume has been demonstrated, this methodology is limited by foreshortened views, geometric modelling, and the assumption that speckles can be tracked from frame to frame, despite their out of plane motion. To circumvent these limitations, a three-dimensional (3D) speckle tracking algorithm was recently developed. Our goal was to evaluate the accuracy of the new 3D-STE side by side with 2D-STE using cardiac magnetic resonance (CMR) as a reference. Apical two- and four-chamber views (A2C and A4C) and real-time 3D datasets (Toshiba Artida 4D System) obtained in 43 patients with a wide range of LV size and function were analysed to measure LV end-systolic and end-diastolic volumes (ESV and EDV) using 2D and 3D-STE techniques. Short-axis CMR images (Siemens 1.5T scanner) acquired on the same day were analysed to obtain ESV and EDV reference values using the method of disks approximation. Reproducibility of both STE techniques was assessed using repeated measurements. While 2D-STE correlated well with CMR (r: 0.72-0.88), it underestimated LV volumes with relatively large biases (10-30 mL) and wide limits of agreement (SD: 36-51 mL), with A2C-derived measurements being worse than A4C values. The 3D-STE measurements showed higher correlation with CMR (0.87-0.92), and importantly smaller biases (1-16 mL) and narrower limits of agreement (SD: 28-37 mL). In addition, 3D-STE showed lower inter- and intra-observer variability (11-14% and 12-13%), than 2D-STE (16-17% and 12-16%, respectively). This is the first study to validate the new 3D-STE technique for LV volume measurements and demonstrate its superior accuracy and reproducibility over previously used 2D-STE technique.
引用
收藏
页码:1565 / 1573
页数:9
相关论文
共 50 条
  • [1] Reliability of left ventricular volumes and function measurements using three-dimensional speckle tracking echocardiography
    Kleijn, Sebastiaan A.
    Aly, Mohamed F. A.
    Terwee, Caroline B.
    van Rossum, Albert C.
    Kamp, Otto
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (02) : 159 - 168
  • [2] Comparison between three-dimensional speckle-tracking echocardiography and cardiac magnetic resonance imaging for quantification of left ventricular volumes and function
    Kleijn, Sebastiaan A.
    Brouwer, Wessel P.
    Aly, Mohamed F. A.
    Russel, Iris K.
    de Roest, Gerben J.
    Beek, Aernout M.
    van Rossum, Albert C.
    Kamp, Otto
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (10) : 834 - 839
  • [3] Quantification of left atrial volumes using three-dimensional wall motion tracking echocardiographic technology: comparison with cardiac magnetic resonance
    Perez de Isla, Leopoldo
    Feltes, Gisela
    Moreno, Joel
    Martinez, Wilfredo
    Saltijeral, Adriana
    de Agustin, Jose A.
    Gomez de Diego, Jose Juan
    Marcos-Alberca, Pedro
    Luaces, Maria
    Ferreiros, Joaquin
    Garcia Fernandez, Miguel Angel
    Macaya, Carlos
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (07) : 793 - 799
  • [4] Accuracy of endocardial border tracking algorithms for real-time three-dimensional echocardiographic quantification of left ventricular volumes
    Soliman, O. I. I.
    Krenning, B. J.
    Geleijnse, M. L.
    Nemes, A.
    Anwar, A. M.
    Van Geuns, R. -J.
    Kirschbaum, S. W.
    Vletter, W. B.
    Galema, T. W.
    Ten Cate, F. J.
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 : 488 - 488
  • [5] Real-time-three-dimensional echocardiographic quantification of left ventricular volumes using a rapid tissue tracking algorithm
    Jacobs, L
    Salgo, IS
    Goonewardena, S
    Sugeng, L
    Weinert, L
    Coon, PD
    Bardo, D
    Gerard, O
    Toledo, E
    Corsi, C
    Mor-Avi, V
    Lang, RM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 308A - 308A
  • [6] Interinstitutional Measurements of Left Ventricular Volumes, Speckle-Tracking Strain, and Dyssynchrony Using Three-Dimensional Echocardiography
    Tsang, Wendy
    Kenny, Cliona
    Adhya, Shaumik
    Kapetanakis, Stam
    Weinert, Lynn
    Lang, Roberto M.
    Monaghan, Mark
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (11) : 1253 - 1257
  • [7] Comparison Between Direct Volumetric and Speckle Tracking Methodologies for Left Ventricular and Left Atrial Chamber Quantification by Three-Dimensional Echocardiography
    Kleijn, Sebastiaan A.
    Aly, Mohamed F. A.
    Terwee, Caroline B.
    van Rossum, Albert C.
    Kamp, Otto
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (07): : 1038 - 1044
  • [8] Emerging Role of Three-Dimensional Speckle Tracking Strain for Accurate Quantification of Left Ventricular Dyssynchrony
    Tanaka, Hidekazu
    Tatsumi, Kazuhiro
    Matsumoto, Kensuke
    Kawai, Hiroya
    Hirata, Ken-ichi
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (09): : E292 - E294
  • [9] A Comparison of Three-Dimensional Speckle Tracking Echocardiography Parameters in Predicting Left Ventricular Remodeling
    Zhong, Junda
    Liu, Peng
    Li, Shuang
    Huang, Xiaomin
    Zhang, Qunhui
    Huang, Jianyu
    Guo, Yan
    Chen, Meixiang
    Ruan, Zheng
    Qin, Changyu
    Xu, Lin
    [J]. JOURNAL OF HEALTHCARE ENGINEERING, 2020, 2020
  • [10] A comparison between QLAB and TomTec full volume reconstruction for real time three-dimensional echocardiographic quantification of left ventricular volumes
    Soliman, Osama I. I.
    Krenning, Boudewijn J.
    Geleiinse, Marcel L.
    Nemes, Attila
    van Geuns, Robert-Jan
    Baks, Timo
    Anwar, Ashraf M.
    Galema, Tjebbe W.
    Vletter, Wim B.
    Ten Cate, Folkert J.
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (09): : 967 - 974