Implementation of gradients of organic solvent in micellar liquid chromatography using DryLab®: Separation of basic compounds in urine samples

被引:22
|
作者
Rodenas-Montano, J. [1 ]
Ortiz-Bolsico, C. [1 ]
Ruiz-Angel, M. J. [1 ]
Garcia-Alvarez-Coque, M. C. [1 ]
机构
[1] Univ Valencia, Dept Quim Analit, E-46100 Valencia, Spain
关键词
Micellar liquid chromatography; Gradient elution; Sodium dodecyl sulphate; 1-Propanol; Basic compounds; Urine samples; EMISSION-TOMOGRAPHY RADIOLIGANDS; SHORT-CHAIN ALCOHOLS; MOBILE-PHASE; RADIOMETRIC DETECTION; COMPUTER-SIMULATION; METABOLITE ANALYSIS; RETENTION BEHAVIOR; BIOGENIC-AMINES; BETA-BLOCKERS; ELUTION;
D O I
10.1016/j.chroma.2014.03.073
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In micellar liquid chromatography (MLC), chromatographic peaks are more evenly distributed compared to conventional reversed-phase liquid chromatography (RPLC). This is the reason that most procedures are implemented using isocratic elution. However, gradient elution may be still useful in MLC to analyse mixtures of compounds within a wide range of polarities, decreasing the analysis time. Also, it benefits the determination of moderately to low polar compounds in physiological fluids performing direct injection: an initial micellar eluent with a low organic solvent content, or a pure micellar (without surfactant) solution, will provide better protection of the column against the proteins in the physiological fluid, and once the proteins are swept away, the elution strength can be increased using a positive linear gradient of organic solvent to reduce the analysis time. This work aims to encourage analysts to implement gradients of organic solvent in MLC, which is rather simple and allows rapid analytical procedures without pretreatment or the need of re-equilibration. The implementation of gradient elution is illustrated through the separation of eight basic compounds (beta-blockers) in urine samples directly injected into the chromatograph, the most hydrophobic showing large retention in both conventional RPLC and MLC. The use of the DryLab (R) software to optimise gradients of organic solvent with eluents containing a fixed amount of surfactant above the critical micellar concentration is shown to provide satisfactory predictions, and can facilitate greatly the implementation of gradient protocols. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:31 / 41
页数:11
相关论文
共 50 条
  • [1] Separation of hydrophobic compounds by nonaqueous micellar electrokinetic chromatography using formamide solvent
    Nakagawa, M
    Lin, JM
    Nakagama, T
    Uchiyama, K
    Hobo, T
    BUNSEKI KAGAKU, 1999, 48 (02) : 239 - 244
  • [2] Micellar liquid chromatography:: A worthy technique for the determination of β-antagonists in urine samples
    Martínez, IR
    Camañas, RMV
    Alvarez-Coque, MCG
    ANALYTICAL CHEMISTRY, 1999, 71 (02) : 319 - 326
  • [3] SEPARATION OF LIPOPHILIC COMPOUNDS BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY WITH ORGANIC MODIFIERS
    OTSUKA, K
    HIGASHIMORI, M
    KOIKE, R
    KARUHAKA, K
    OKADA, Y
    TERABE, S
    ELECTROPHORESIS, 1994, 15 (10) : 1280 - 1283
  • [4] Optimization of separation of a complex mixture of natural and synthetic corticoids by micellar liquid chromatography using sodium dodecyl sulphate - Application to urine samples
    Santos-Montes, A
    Izquierdo-Hornillos, R
    JOURNAL OF CHROMATOGRAPHY B, 1999, 724 (01): : 53 - 63
  • [5] Separation of hydrophobic solutes by organic-solvent-based micellar electrokinetic chromatography using cation surfactants
    Gong, Suxuan
    Liu, Fujia
    Li, Wei
    Gao, Fei
    Gao, Chunjin
    Liao, Yiping
    Liu, Huwei
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1121 (02) : 274 - 279
  • [6] Control of separation selectivity in micellar electrokinetic chromatography by modification of the micellar phase with solubilized organic compounds
    Katsuta, S
    Saitoh, K
    JOURNAL OF CHROMATOGRAPHY A, 1997, 780 (1-2) : 165 - 178
  • [7] LIQUID-CHROMATOGRAPHY SEPARATION OF ORGANIC ACIDIC COMPOUNDS
    JANDERA, P
    ENGELHARDT, H
    CHROMATOGRAPHIA, 1980, 13 (01) : 18 - 23
  • [8] Analysis of epinephrine, norepinephrine, and dopamine in urine samples of hospital patients by micellar liquid chromatography
    Daniel García Ferrer
    Aurelio García García
    Juan Peris-Vicente
    José Vicente Gimeno-Adelantado
    Josep Esteve-Romero
    Analytical and Bioanalytical Chemistry, 2015, 407 : 9009 - 9018
  • [9] Direct determination of verapamil in urine and serum samples by micellar liquid chromatography and fluorescence detection
    Rambla-Alegre, M.
    Gil-Agusti, M. T.
    Capella-Peiro, M. E.
    Carda-Broch, S.
    Esteve-Romero, J. S.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 839 (1-2): : 89 - 94
  • [10] Analysis of epinephrine, norepinephrine, and dopamine in urine samples of hospital patients by micellar liquid chromatography
    Garcia Ferrer, Daniel
    Garcia Garcia, Aurelio
    Peris-Vicente, Juan
    Vicente Gimeno-Adelantado, Jose
    Esteve-Romero, Josep
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (30) : 9009 - 9018