Application of multi-wavelength fluorometry for monitoring wastewater treatment process dynamics

被引:41
|
作者
Tartakovsky, B
Lishman, LA
Legge, RL
机构
[1] UNIV WATERLOO,DEPT CHEM ENGN,WATERLOO,ON N2L 3G1,CANADA
[2] TECHNION ISRAEL INST TECHNOL,FAC CHEM ENGN,IL-32000 HAIFA,ISRAEL
[3] UNIV WATERLOO,DEPT CIVIL ENGN,WATERLOO,ON N2L 3G1,CANADA
关键词
activated sludge process; bioprocess monitoring; fluorescent spectroscopy; wastewater treatment; regression analysis;
D O I
10.1016/S0043-1354(96)00196-0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Much of the methodology employed for characterizing wastewater and in modeling wastewater treatment processes employs off-line analysis. Off-line analysis is time consuming and not ideally suited to developing process control strategies. Clearly a rapid, inexpensive and reliable method suitable for following organic consumption and biomass production on-line would be very useful. In this study multiple excitation-multiple emission fluorometry was examined as a method for monitoring wastewater treatment processes. Results were first obtained for defined protein solutions and activated sludge to identify characteristic excitation and emission wavelength pairs. These results were then used to develop a rapid off-line assay for measurement of synthetic feeds consisting of protein substrates for batch aerobic and anoxic wastewater treatment processes and for on-line monitoring of cellular metabolic states in an anoxic process. Step-wise multiple regression and principal component analysis were employed for data analysis. The former was used to determine the most informative excitation and emission wavelength pairs while the latter was applied to reduce fluorescent spectra dimensions. Analysis of the batch kinetics suggests that this approach is valid and revealed some dynamic features of protein utilization and biomass accumulation under aerobic and anoxic conditions. A correlation was developed between COD-removal rates and the fluorescence signals in the two processes using fluorescent emission spectra rather than single signals. The data suggests that this multiple excitation-multiple emission fluorometry may be a suitable method for following wastewater and activated sludge dynamics and could be used as the basis for the development of expert system based biosensors. Copyright (C) 1996 Published by Elsevier Science Ltd
引用
收藏
页码:2941 / 2948
页数:8
相关论文
共 50 条
  • [1] Multi-wavelength fluorometry for anaerobic digestion process monitoring
    Morel, E
    Santamaria, K
    Perrier, M
    Guiot, SR
    Tartakovsky, B
    [J]. WATER SCIENCE AND TECHNOLOGY, 2005, 52 (1-2) : 465 - 471
  • [2] Application of multi-wavelength fluorometry for on-line monitoring of an anaerobic digestion process
    Morel, E
    Santamaria, K
    Perrier, M
    Guiot, SR
    Tartakovsky, B
    [J]. WATER RESEARCH, 2004, 38 (14-15) : 3287 - 3296
  • [3] Application of scanning fluorometry for monitoring of a fermentation process
    Tartakovsky, B
    Sheintuch, M
    Hilmer, JM
    Scheper, T
    [J]. BIOTECHNOLOGY PROGRESS, 1996, 12 (01) : 126 - 131
  • [4] Application and key techniques of multi-wavelength lidar
    Song, Shalei
    Li, Pingxiang
    Gong, Wei
    Ma, Yingying
    Li, Jun
    [J]. GEOINFORMATICS 2008 AND JOINT CONFERENCE ON GIS AND BUILT ENVIRONMENT: ADVANCED SPATIAL DATA MODELS AND ANALYSES, PARTS 1 AND 2, 2009, 7146
  • [5] Multi-wavelength dual polarisation lidar for monitoring precipitation process in the Cloud Seeding Technique
    Sudhakar, P.
    Sheela, K. Anitha
    Rao, D. Ramakrishna
    Satyanarayana, Malladi
    [J]. LIDAR REMOTE SENSING FOR ENVIRONMENTAL MONITORING XV, 2016, 9879
  • [6] Multi-wavelength Reflectivity Monitoring on Growth of AlN on Si
    Iyechika, Yasushi
    Tsukui, Masayuki
    Miyano, Kiyotaka
    Takahashi, Hideshi
    [J]. 2019 COMPOUND SEMICONDUCTOR WEEK (CSW), 2019,
  • [7] A Multi-wavelength Photoplethysmography System for Sleep Quality Monitoring
    Nabavi, Seyeclfakhreddin
    Cogan, John
    Roy, Asim
    Canfield, Brandon
    Kibler, Robert
    Emerick, Collin
    [J]. 2023 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS, ICCE, 2023,
  • [8] Multi-wavelength monitoring of GRS1915+105
    Bandyopadhyay, R
    Martini, P
    Gerard, E
    Charles, PA
    Wagner, RM
    Shrader, C
    Shahbaz, T
    Mirabel, IF
    [J]. PROCEEDINGS OF THE FOURTH COMPTON SYMPOSIUM, PTS 1 AND 2: PT 1: THE COMPTON OBSERVATORY IN REVIEW; PT 2: PAPERS AND PRESENTATIONS, 1997, (410): : 892 - 896
  • [9] Multi-wavelength radio monitoring of EGRET sources and candidates
    Edwards, PG
    Lovell, JEJ
    Hartman, RC
    Tornikoski, M
    Lainela, M
    McCulloch, PM
    Gaensler, BM
    Hunstead, RW
    [J]. PROCEEDINGS OF THE FOURTH COMPTON SYMPOSIUM, PTS 1 AND 2: PT 1: THE COMPTON OBSERVATORY IN REVIEW; PT 2: PAPERS AND PRESENTATIONS, 1997, (410): : 1428 - 1432
  • [10] MULTI-WAVELENGTH SINGLE TREATMENT REJUVENATION PROGRAM
    Campo-Voegeli, Antonio
    Pilar Arboles-Bermejo, Maria
    [J]. LASERS IN SURGERY AND MEDICINE, 2009, : 108 - 109