Distortion correction for high-resolution single-shot EPI DTI using a modified field-mapping method

被引:10
|
作者
Xiong, Yuhui [1 ]
Li, Guangqi [1 ]
Dai, Erpeng [1 ]
Wang, Yishi [1 ]
Zhang, Zhe [1 ]
Guo, Hua [1 ]
机构
[1] Tsinghua Univ, Ctr Biomed Imaging Res, Sch Med, Dept Biomed Engn, Beijing, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
distortion correction; field map; high-resolution DTI; intensity correction; single-shot EPI; ECHO-PLANAR IMAGES; DIFFUSION TENSOR; GEOMETRIC DISTORTION; ARTIFACTS; GRAPPA; SENSE;
D O I
10.1002/nbm.4124
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purpose The widely used single-shot EPI (SS-EPI) diffusion tensor imaging (DTI) suffers from strong image distortion due to B-0 inhomogeneity, especially for high-resolution imaging. Traditional methods such as the field-mapping method and the top-up method have various deficiencies in high-resolution SS-EPI DTI distortion correction. This study aims to propose a robust distortion correction approach, which combines the advantages of traditional methods and overcomes their deficiencies, for high-resolution SS-EPI DTI. Methods The proposed correction method is based on the echo planar spectroscopic imaging field-mapping followed by an intensity correction procedure. To evaluate the efficacy of distortion correction, the proposed method was compared with the conventional field-mapping method and the top-up method, using a newly developed quantitative evaluation framework. The correction results were also compared with multi-shot EPI DTI to investigate whether the proposed method can provide high-resolution SS-EPI DTI with high geometric fidelity and high time efficiency. Results The results show that accurate field-mapping and intensity correction are critical to distortion correction in high-resolution SS-EPI DTI. The proposed method can provide more precise field maps and better correction results than the other two methods (p < 0.0001), and the corrected images show higher geometric fidelity than those from MS-EPI DTI. Conclusion An effective method is proposed to reduce image distortion in high-resolution SS-EPI DTI. It is practical to achieve high-resolution DTI with high time efficiency and high structure accuracy using this method.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Dynamic field mapping and distortion correction using single-shot blip-rewound EPI and joint multi-echo reconstruction
    Wu, Wenchuan
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (01) : 82 - 97
  • [2] Distortion correction of single-shot EPI enabled by deep-learning
    Hu, Zhangxuan
    Wang, Yishi
    Zhang, Zhe
    Zhang, Jieying
    Zhang, Huimao
    Guo, Chunjie
    Sun, Yuejiao
    Guo, Hua
    NEUROIMAGE, 2020, 221
  • [3] Localized high-resolution DTI of the human midbrain using single-shot EPI, parallel imaging, and outer-volume suppression at 7 T
    Wargo, Christopher J.
    Gore, John C.
    MAGNETIC RESONANCE IMAGING, 2013, 31 (06) : 810 - 819
  • [4] Single-shot, interferometric, high-resolution, terahertz field diagnostic
    Kim, KY
    Yellampalle, B
    Rodriguez, G
    Averitt, RD
    Taylor, AJ
    Glownia, JH
    APPLIED PHYSICS LETTERS, 2006, 88 (04) : 1 - 3
  • [5] Simultaneous superresolution reconstruction and distortion correction for single-shot EPI DWI using deep learning
    Ye, Xinyu
    Wang, Peipei
    Li, Sisi
    Zhang, Jieying
    Lian, Yuan
    Zhang, Yajing
    Lu, Jie
    Guo, Hua
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (06) : 2456 - 2470
  • [6] High resolution single-shot EPI at 7T
    Speck, Oliver
    Stadler, J.
    Zaitsev, M.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2008, 21 (1-2) : 73 - 86
  • [7] High resolution single-shot EPI at 7T
    Oliver Speck
    J. Stadler
    M. Zaitsev
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2008, 21
  • [8] TWO-DIMENSIONAL FIELD-MAPPING AND FIELD CORRECTION FOR A HIGH-RESOLUTION MAGNET WITH ABERRATION COMPENSATION
    MINEHARA, E
    BILLQUIST, P
    DENHARTOG, P
    KUTSCHERA, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 252 (01): : 101 - 106
  • [9] Single-shot, high-resolution, THz field reconstruction using phase-retrieval
    Yellampalle, Balakishore
    Kim, KiYong
    Averitt, Richard D.
    Rodriguez, George
    Glownia, James H.
    Taylor, Antoniette J.
    ULTRAFAST PHENOMENA XV, 2007, 88 : 796 - +
  • [10] Influence of SENSE on image properties in high-resolution single-shot echo-planar DTI
    Jaermann, T
    Pruessmann, KP
    Valavanis, A
    Kollias, S
    Boesiger, P
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (02) : 335 - 342