Parametric investigation of thermal characteristic in trapezoidal cavity receiver for a linear Fresnel solar collector concentrator

被引:102
|
作者
Dabiri, Soroush [1 ]
Khodabandeh, Erfan [2 ]
Poorfar, Alireza Khoeini [3 ]
Mashayekhi, Ramin [4 ]
Toghraie, Davood [5 ]
Zade, Seyed Ali Abadian [6 ]
机构
[1] Univ Tehran, Environm Engn Dept, 16th Azar St,Enghelab Sq,POB 14155-6619, Tehran, Iran
[2] Amirkabir Univ Technol, Tehran Polytech, Mech Engn Dept, 424 Hafez Ave,POB 15875-4413, Tehran, Iran
[3] IUST, Sch Mech Engn, Combust Res Lab, Tehran 1689613114, Iran
[4] Islamic Azad Univ, Khomeinishahr Branch, Young Researchers & Elite Club, Khomeinishahr, Iran
[5] Islamic Azad Univ, Khomeinishahr Branch, Dept Mech Engn, Khomeinishahr, Iran
[6] Isfahan Univ Technol, Dept Mech Engn, Esfahan, Iran
关键词
Trapezoidal cavity receiver; Linear Fresnel reflector; Computational fluid dynamics; Discrete Transfer Radiation Model; STEAM POWER-PLANT; RADIATIVE HEAT-LOSSES; LID-DRIVEN CAVITY; NUMERICAL-SIMULATION; NATURAL-CONVECTION; MIXED CONVECTION; WATER NANOFLUID; REFLECTOR; FLOW; MODEL;
D O I
10.1016/j.energy.2018.04.025
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solar collectors especially Linear Fresnel Reflectors are one of the main implements to utilize the energy of sun light. The receiver cavity of the collector is recognized as an important component of each concentrating solar power plant. In this study, the heat transfer rate and heat loss in a trapezoidal cavity of the linear Fresnel reflector are analyzed. The calculations are performed for steady-state, laminar model in which temperature-dependent density is assumed for the air inside the cavity. The effects of the cavity angle and the effect of the tube size are evaluated, in various models. DTRM radiation model is employed for the simulation, while considering radiation, conduction and convection heat transfers are as the boundary conditions. Finally, it will be observed that by increasing the cavity angle, the total value for heat transfer rate is increased, but the heat absorbed by each tube is decreased. The results also show that the tube size is less effective on heat transfer rate compared to the cavity angle. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:17 / 26
页数:10
相关论文
共 50 条
  • [1] Numerical simulation of a trapezoidal cavity receiver for a linear Fresnel solar collector concentrator
    Facao, Jorge
    Oliveira, Armando C.
    [J]. RENEWABLE ENERGY, 2011, 36 (01) : 90 - 96
  • [2] Optical and thermal investigation of a linear Fresnel collector with trapezoidal cavity receiver
    Tsekouras, P.
    Tzivanidis, C.
    Antonopoulos, K.
    [J]. APPLIED THERMAL ENGINEERING, 2018, 135 : 379 - 388
  • [3] Parametric Study on the Thermal Performance of a Trapezoidal Cavity Absorber for a Linear Fresnel Solar Collector
    Rabhi, Louiza
    Khmou, Ahmed
    Boutammachte, Noureddine
    Barek, Abdelaali Ait M.
    [J]. INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2019, 9 (02): : 830 - 839
  • [4] Thermal performance of linear Fresnel reflecting solar concentrator with trapezoidal cavity absorbers
    Singh, Panna Lal
    Sarviya, R. M.
    Bhagoria, J. L.
    [J]. APPLIED ENERGY, 2010, 87 (02) : 541 - 550
  • [5] Performance investigation on a linear Fresnel lens solar collector using cavity receiver
    Lin, M.
    Sumathy, K.
    Dai, Y. J.
    Zhao, X. K.
    [J]. SOLAR ENERGY, 2014, 107 : 50 - 62
  • [6] Heat losses in a trapezoidal cavity receiver of a linear Fresnel collector: A CFD approach
    Alcalde-Morales, Sergio
    Valenzuela, Loreto
    Serrano-Aguilera, J. J.
    [J]. HELIYON, 2023, 9 (08)
  • [7] Heat loss of a trapezoidal cavity absorber for a linear Fresnel reflecting solar concentrator
    Flores Larsen, S.
    Altamirano, M.
    Hernandez, A.
    [J]. RENEWABLE ENERGY, 2012, 39 (01) : 198 - 206
  • [8] Thermal Performance Model and Parametric Studies of a Trapezoidal Fresnel Solar Receiver
    Ordonez, Freddy
    Jaramillo, Daniela
    [J]. INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS (SOLARPACES 2017), 2018, 2033
  • [9] A comprehensive model for optical and thermal characterization of a linear Fresnel solar reflector with a trapezoidal cavity receiver
    Qiu, Yu
    He, Ya-Ling
    Wu, Ming
    Zheng, Zhang-Jing
    [J]. RENEWABLE ENERGY, 2016, 97 : 129 - 144
  • [10] Simulation of a linear Fresnel solar collector concentrator
    Facao, Jorge
    Oliveira, Armando C.
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2010, 5 (03) : 125 - 129