Extended collimator model for pencil-beam dose calculation in proton radiotherapy

被引:28
|
作者
Kanematsu, Nobuyuki
Akagi, Takashi
Takatani, Yasuyuki
Yonai, Shunsuke
Sakamoto, Hidenobu
Yamashita, Haruo
机构
[1] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
[2] Hyogo Ion Beam Med Ctr, Tatsuno, Hyogo 6705165, Japan
[3] Mitsubishi Electr Corp, Hyogo Ku, Kobe, Hyogo 6528555, Japan
[4] Shizuoka Canc Ctr, Shizuoka 4118777, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 19期
关键词
D O I
10.1088/0031-9155/51/19/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a simple collimator model to improve the accuracy of penumbra behaviour in pencil-beam dose calculation for proton radiotherapy. In this model, transmission of particles through a three-dimensionally extended opening of a collimator is calculated in conjunction with phase-space distribution of the particles. Comparison of the dose distributions calculated using the new three-dimensional collimator model and the conventional two-dimensional model to lateral dose profiles experimentally measured with collimated proton beams showed the superiority of the new model over the conventional one.
引用
收藏
页码:4807 / 4817
页数:11
相关论文
共 50 条
  • [1] Evaluation of a pencil-beam dose calculation technique for charged particle radiotherapy
    Petti, PL
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (05): : 1049 - 1057
  • [2] Incorporating partial shining effects in proton pencil-beam dose calculation
    Li, Yupeng
    Zhang, Xiaodong
    Lii, MingFwu
    Sahoo, Narayan
    Zhu, Ron X.
    Gillin, Michael
    Mohan, Radhe
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (03): : 605 - 616
  • [3] Implementation of apertures in a proton pencil-beam dose algorithm
    Depauw, N.
    Kooy, H. M.
    Daartz, J.
    Bussiere, M.
    Batin, E.
    Madden, T.
    Williams, M.
    Schueman, J.
    Clasie, B. M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (02)
  • [4] AN ANALYTICAL MODEL FOR PROTON BEAM COLLIMATOR SCATTERING DOSE CALCULATION
    Vidal, M.
    Szymanowski, H.
    Nauraye, C.
    De Marzi, L.
    Kajdrowicz, T.
    Ferrand, R.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S533 - S533
  • [5] Monte Carlo vs. pencil-beam dose calculation for uncertainty estimation in proton therapy
    Wahl, N.
    Wieser, H.
    Burigo, L.
    Bangert, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S731 - S731
  • [6] Incorporation of the aperture thickness in proton pencil-beam dose calculations
    Slopsema, Roelf L.
    Kooy, Hanne M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (21): : 5441 - 5453
  • [7] A pencil-beam photon algorithm for a miniature multileaf collimator
    Dong, L
    Shiu, AS
    Tung, SS
    Hogstrom, KR
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 92 - 95
  • [8] A pencil-beam photon dose algorithm for stereotactic radiosurgery using a miniature multileaf collimator
    Dong, L
    Shiu, AM
    Tung, S
    Hogstrom, K
    MEDICAL PHYSICS, 1998, 25 (06) : 841 - 850
  • [9] Experimental evaluation of a spatial resampling technique to improve the accuracy of pencil-beam dose calculation in proton therapy
    Egashira, Yusuke
    Nishio, Teiji
    Matsuura, Taeko
    Kameoka, Satoru
    Uesaka, Mitsuru
    MEDICAL PHYSICS, 2012, 39 (07) : 4104 - 4114
  • [10] Evaluation of IMRT Dose Calculation Based On Pencil-Beam and AAA Algorithms
    Yuan, Y.
    Duan, J.
    Popple, R.
    Brezovich, I.
    MEDICAL PHYSICS, 2012, 39 (06) : 3829 - 3829