A Store-and-Forward Tele-Audiology Solution to Promote Efficient Screenings for Ototoxicity during Cisplatin Cancer Treatment

被引:13
|
作者
Dille, Marilyn F. [1 ,2 ]
McMillan, Garnett P. [1 ,3 ]
Helt, Wendy J. [1 ]
Konrad-Martin, Dawn [1 ,2 ]
Jacobs, Peter [1 ,4 ]
机构
[1] VA Portland Healthcare Syst VAPORHCS, NCRAR, Portland, OR 97239 USA
[2] Oregon Hlth & Sci Univ, Dept Otolaryngol HNS, Portland, OR 97201 USA
[3] Oregon Hlth & Sci Univ, Dept Publ Hlth & Prevent Med, Portland, OR 97201 USA
[4] Oregon Hlth & Sci Univ, Dept Biomed Engn, Portland, OR 97201 USA
关键词
Chemotherapy; cisplatin; OtoID; ototoxicity; telehealth; tele-audiology; veterans; PRODUCT OTOACOUSTIC EMISSIONS; HEARING-LOSS; PORTABLE AUDIOMETER; MODEL; FREQUENCY;
D O I
10.3766/jaaa.15028
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Background: Tele-audiology improves access, controls cost, and improves efficiency of many aspects within health care. We have developed and validated a device, the ototoxicity identification device (OtoID), which enables remote hearing monitoring by a patient during chemotherapy treatment. Aspects of the design such as patient self-testing and texting of results to the audiology clinic are important features of this device. Purpose: The purpose of this article is to present the efficacy and effectiveness of the OtoID hearing screener. Research Design: A repeated measures design was used in this study. Study Sample: Twenty-one veterans undergoing cisplatin chemotherapy were recruited in this study. Data Collection and Analysis: Participants were tested using the OtoID at each cisplatin treatment by an audiologist using the manual mode of test and the participant using the automated mode of test. Test sensitivity and specificity were developed from the detection (yes/no) of an American Speech-Language-Hearing Association (ASHA) change in hearing. Results: The OtoID had a test sensitivity of 80.6% and specificity of 85.3%. A logistic regression model analysis of the probability of an ASHA shift identified by the automated OtoID was conducted. Separate models were fit to establish effects of age, average baseline thresholds in the sensitive range for ototoxicity (SRO), and dose of cisplatin on the probability of a positive hearing change result. Interactions were also included to evaluate these effects on the sensitivity and false-positive rates of the automated test. Results indicated no statistically significant effects of age, of baseline hearing in the SRO frequencies, or of cisplatin dose. Conclusions: The OtoID automated test can be recommended for use. The automated test provides significant personnel efficiencies. The modem with simple text messaging function recently added to the device improves on these efficiencies.