Anesthetic Management of Transapical Off-Pump Mitral Valve Repair With NeoChord Implantation

被引:8
|
作者
Kavakli, Ali Sait [1 ]
Ozturk, Nilgun Kavrut [1 ]
Ayoglu, Raif Umut [2 ]
Emmiler, Mustafa [2 ]
Ozyurek, Lutfi [1 ]
Inanoglu, Kerem [1 ]
Ozmen, Sadik [1 ]
机构
[1] Antalya Training & Res Hosp, Dept Anaesthesiol & Reanimat, Antalya, Turkey
[2] Antalya Educ & Res Hosp, Dept Cardiovasc Surg, Antalya, Turkey
关键词
mitral valve repair; transapical; off-pump; NeoChord procedure; anesthetic management; SURGERY; ECHOCARDIOGRAPHY; ANALGESIA; EFFICACY; CHORDAE; SAFETY;
D O I
10.1053/j.jvca.2016.06.031
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objectives: Various minimally invasive surgical approaches have been used in mitral valve (MV) surgery. The transapical off-pump mitral valve intervention with NeoChord implantation (TOP-MINI) is a minimally invasive, alternative procedure for the treatment of degenerative mitral regurgitation. There are several special considerations for the anesthesiologist during the TOP-MINI procedure. The main purpose of this study was to present the anesthetic management of the TOP-MINI procedure. Design: An observational study. Setting: Training and research hospital. Participants: Adult patients who underwent MV repair with the NeoChord DS1000 system (NeoChord Inc, St Louis Park, MN). Interventions: The study included 12 consecutive patients who underwent MV repair with the NeoChord DS1000 system at the Antalya Training and Research Hospital, Antalya, Turkey, between June 2014 and December 2015. A record was made of preoperative demographic details, comorbidities, preoperative and postoperative mitral regurgitation severity, preoperative and postoperative forced expiratory volume in 1 second values, use of blood products and vasoactive drugs, surgical times, mechanical ventilation times, intensive care unit (ICU) and hospital length of stay, visual analog scale scores, analgesic requirement in ICU and perioperative complications. Measurements and Main Results: TOP-MINI was performed completely off-pump in 12 patients. Intraoperative salvaged blood via cell-saver was 660 +/- 196 mL. Patients required 0.8 +/- 0.7 U of red blood cells and 2.0 +/- 0.9 U of fresh frozen plasma in the ICU. Inotropic support was used in 5 patients. There was a significant decline in mean arterial pressure from before surgery to during implantation (70.9 +/- 4.5 mmHg v 51.7 +/- 5.8 mmHg, respectively). A statistically significant increase was demonstrated in mean arterial pressure from during implantation to postimplantation (51.7 +/- 5.8 mmHg v 67.0 +/- 6.8 mmHg, respectively). There were no significant differences in preoperative and postoperative forced expiratory volume in 1 second values. Defibrillation was required in 1 patient, and temporary atrial fibrillation was observed in 1 patient during the procedure. Atelectasis occurred in the postoperative period in 1 patient. The mean visual analog scale score was 3.6 +/- 1.4, and the mean tramadol consumption was 77 +/- 39 mg in the ICU. Extubation time and the mean length of stay in the ICU and hospital were 2.6 +/- 0.5 hours, 19.8 +/- 2.7 hours, 5 +/- 1 days, respectively. Conclusions: The TOP-MINI procedure requires complex anesthetic management. Transesophageal echocardiographic guidance is essential for this procedure. One-lung ventilation, fluid administration, avoidance of hypothermia, and pain management are the bases for anesthetic management. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1587 / 1593
页数:7
相关论文
共 50 条
  • [1] Clinical experience of transapical off-pump mitral valve repair with NeoChord implantation
    Kalompatsou, A.
    Beneki, E.
    Dimitroglou, Y.
    Koukos, M.
    Aggeli, D.
    Tolis, E.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [2] Transapical off-pump mitral valve repair with NeoChord implantation: Is less better?
    Coutinho, Goncalo F.
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2021, 40 (12) : 943 - 945
  • [3] Transapical off-pump mitral valve repair with NeoChord implantation: A systematic review
    Ahmed, Ahmed
    Abdel-Aziz, Tarek A.
    AlAsaad, Mohannad M. R.
    Majthoob, Motaz
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (04) : 1492 - 1498
  • [4] CT for the Transapical Off-Pump Mitral Valve Repair With Neochord Implantation Procedure
    Colli, Andrea
    Zucchetta, Fabio
    Kliger, Chad
    Bellu, Roberto
    Francone, Marco
    Sedati, Pietro
    Jelnin, Vladimir
    Ruiz, Carlos E.
    Manzan, Erica
    Besola, Laura
    Bizzotto, Eleonora
    Gerosa, Gino
    JACC-CARDIOVASCULAR IMAGING, 2017, 10 (11) : 1397 - 1400
  • [5] An early European experience with transapical off-pump mitral valve repair with NeoChord implantation
    Colli, Andrea
    Manzan, Erica
    Aidietis, Audrius
    Rucinskas, Kestutis
    Bizzotto, Eleonora
    Besola, Laura
    Pradegan, Nicola
    Pittarello, Demetrio
    Janusauskas, Vilius
    Zakarkaite, Diana
    Drasutiene, Agne
    Lipnevicius, Arturas
    Danner, Bernhard C.
    Sievert, Horst
    Vaskelyte, Laura
    Schnelle, Nalan
    Salizzoni, Stefano
    Marro, Massimo
    Rinaldi, Mauro
    Kurnicka, Katarzyna
    Wrobel, Kristof
    Ceffarelli, Mariano
    Savini, Carlo
    Pacini, Davide
    Gerosa, Gino
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (03) : 460 - 466
  • [6] Transapical off-pump mitral valve repair with Neochord implantation: Early clinical results
    Colli, Andrea
    Manzan, Erica
    Zucchetta, Fabio
    Bizzotto, Eleonora
    Besola, Laura
    Bagozzi, Lorenzo
    Bellu, Roberto
    Sarais, Cristiano
    Pittarello, Demetrio
    Gerosa, Gino
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 204 : 23 - 28
  • [7] Safety, Feasibility And Efficacy Of Transapical Off-Pump Mitral Valve Repair With Neochord Implantation
    Colli, Andrea
    Manzan, Erica
    Zucchetta, Fabio
    Sarais, Cristiano
    Pittarello, Demetrio
    Gerosa, Gino
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B234 - B235
  • [8] Mitral valve repair with transapical, off-pump neochord implantation. Initial experience
    Perez-Camargo, Daniel
    Cobiella-Carnicer, Javier
    Mahia-Casado, Patricia
    Carnero-Alcazar, Manuel
    Montero-Cruces, Lourdes
    Campelos-Fernandez, Paula
    Nombela-Franco, Luis
    Castellanos, Luis C. Maroto
    CIRUGIA CARDIOVASCULAR, 2023, 30 : S21 - S27
  • [9] Transapical off-pump neochord implantation procedure for mitral valve insufficiency
    Colli, A.
    Zucchetta, F.
    Manzan, E.
    Sarais, C.
    Pittarello, D.
    Speziali, G.
    Gerosa, G. I. N. O.
    EUROPEAN HEART JOURNAL, 2014, 35 : 36 - 36
  • [10] Review of transapical off-pump mitral valve intervention with NeoChord implantation
    Hassanabad, Ali Fatehi
    Kent, William D. T.
    Adams, Corey
    CURRENT OPINION IN CARDIOLOGY, 2021, 36 (02) : 130 - 140