Selective solid phase extraction of copper using a new Cu(II)-imprinted polymer and determination by inductively coupled plasma optical emission spectroscopy (ICP-OES)

被引:83
|
作者
Yilmaz, Vedat [1 ,2 ]
Arslan, Zikri [1 ]
Hazer, Orhan [3 ]
Yilmaz, Hayriye [2 ]
机构
[1] Jackson State Univ, Dept Chem & Biochem, Jackson, MS USA
[2] Erciyes Univ, Dept Analyt Chem, Fac Pharm, Kayseri, Turkey
[3] Bozok Univ, Fac Art & Sci, Dept Chem, Yozgat, Turkey
基金
美国国家卫生研究院;
关键词
Cu(II)-imprinted polymer; Solid phase extraction; Seawater; Bone ash; Fish otolith; Inductively coupled optical emission spectroscopy; IONIC IMPRINTED POLYMER; TRACE-ELEMENT DETERMINATION; NATURAL-WATER SAMPLES; CHELATING RESIN; PRECONCENTRATION; METALS; SPECTROMETRY; SEAWATER; RECOGNITION; ONLINE;
D O I
10.1016/j.microc.2013.12.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports the preparation of a novel Cu(II)-ion imprinted polymer using 2-thiozylmethacrylamide (TMA) for on-line preconcentration of Cu(II) prior to its determination by inductively coupled optical emission spectroscopy (ICP-OES). Cu(II)-TMA monomer (complex) was synthesized and copolymerized via bulk polymerization method in the presence of ethyleneglycoldimethacrylate cross-linker. The resulting polymer was washed with 5% (v/v) HNO3 to remove Cu(II) ions and then with water until a neutral pH. The ion imprinted polymer was characterized by FT-IR and scanning electron microscopy. The experimental conditions were optimized for online preconcentration of Cu(II) using a minicolumn of ion imprinted polymer (IIP). Quantitative retention was achieved between pH 5.0 and 6.0, whereas the recoveries for the non-imprinted polymer (NIP) were about 61%. The IIP showed about 30 times higher selectivity to Cu(II) in comparison to NIP. The IIP also exhibited excellent selectivity for Cu(II) against the competing transition and heavy metal ions, including Cd, Co, Cr, Fe, Mn, Ni, Pb and Zn. Computational calculations revealed that the selectivity of IIP was mediated by the stability of Cu(II)TMA complex which was far more stable than those of Co(II), Ni(II) and Zn(II) that have similar charge and ionic radii to Cu(II). A volume of 10 mL sample solution was loaded onto the column at 4.0 mL min(-1) by using a sequential injection system (FIALab 3200) followed by elution with 1.0 mL of 2% (v/v) HNO3. The relative standard deviation (RSD) and limit of detection (LOD, 3 s) of the method were 3.2% and 0.4 mu g L-1, respectively. The method was successfully applied to determination of Cu(II) in fish otoliths (CRM 22), bone ash (SRM 1400) and coastal seawater and estuarine water samples. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 50 条
  • [1] The determination of phosphate in rocks and iron ores using inductively coupled plasma with optical emission spectroscopy (ICP-OES)
    Mostert, M. M. R.
    [J]. GEOCHEMISTRY-EXPLORATION ENVIRONMENT ANALYSIS, 2019, 19 (04) : 465 - 473
  • [2] Determination of Some Trace Elements in Dried Red Plum Using Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES)
    Sukru, Kalayci
    Sinan, Muhammet
    [J]. IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2022, 41 (11): : 3742 - 3746
  • [3] Determination of Minerals in Kefir by Inductively Coupled Plasma-Optical Emission Spectrometer (ICP-OES)
    Ozcan, Tulay
    [J]. ASIAN JOURNAL OF CHEMISTRY, 2010, 22 (08) : 6589 - 6594
  • [4] The determination of gold in ore samples by inductively coupled plasma optical emission spectrometry (ICP-OES)
    Sekhar, KC
    Gupta, KK
    Bhattacharya, S
    Chakravarthy, S
    [J]. ATOMIC SPECTROSCOPY, 2004, 25 (04) : 165 - 169
  • [5] DETERMINATION OF HEAVY METALS IN BEE HONEY USING BY INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY (ICP-OES)
    Demirezen, Dilek
    Aksoy, Ahmet
    [J]. GAZI UNIVERSITY JOURNAL OF SCIENCE, 2005, 18 (04): : 569 - 575
  • [6] EXTRACTION INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION-SPECTROMETRY (ICP-OES) DETERMINATION OF TRACES OF PHOSPHORUS IN TUNGSTEN
    BAUER, G
    WEGSCHEIDER, W
    MULLER, K
    ORTNER, HM
    [J]. MIKROCHIMICA ACTA, 1989, 3 (3-6) : 399 - 412
  • [7] Spectral interferences in the determination of rhenium in molybdenum and copper concentrates by inductively coupled plasma optical emission spectrometry (ICP-OES)
    Karadjov, Metody
    Velitchkova, Nikolaya
    Veleva, Olga
    Velichkov, Serafim
    Markov, Pavel
    Daskalova, Nonka
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 119 : 76 - 82
  • [8] Determination of Lithium in High Salinity Samples by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES)
    Han Tao
    Yu Xiao-ping
    Guo Ya-fei
    Li Ming-li
    Duo Ji
    Deng Tian-long
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (04) : 1214 - 1220
  • [9] Determination of total strontium in Uruguayan rice by inductively coupled plasma optical emission spectrometry (ICP-OES)
    Rivero-Huguet, Mario
    Darre, Elena
    [J]. ATOMIC SPECTROSCOPY, 2006, 27 (03) : 80 - 85
  • [10] Evaluation of elements in Persian tahini (ardeh) using ICP-OES (inductively coupled plasma optical emission spectroscopy) method
    Kargarghomsheh, Pegah
    Noghre, Naeemeh
    Sharifiarab, Gholamali
    Mehraie, Abbas
    Tooryan, Fahimeh
    Sani, Mahmood Alizadeh
    Shariatifar, Nabi
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2023,