Applications of SU-8 in the development of a Single Ion Hit Facility

被引:1
|
作者
Arteaga-Marrero, N. [1 ]
Astromskas, G. [2 ]
Olsson, M. G. [3 ]
Elfman, M. [1 ]
Kristiansson, P. [1 ]
Nilsson, E. J. C. [1 ]
Nilsson, C. [1 ]
Pallon, J. [1 ]
机构
[1] Lund Univ, Div Nucl Phys, Dept Phys, SE-22100 Lund, Sweden
[2] Lund Univ, Div Solid State Phys, Dept Phys, SE-22100 Lund, Sweden
[3] Lund Univ, Dept Infect Med, SE-22184 Lund, Sweden
关键词
Single Ion Hit Facility (SIHF); Cell irradiation; SU-8; PMMA; EBL; CELL IRRADIATION; PHOTORESIST; ARRAYS;
D O I
10.1016/j.nimb.2009.03.009
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Lund Nuclear Microprobe (LNM) has been adapted to be used as a Single Ion Hit Facility (SIHF) for proton cell irradiation experiments at low dose. In order to test the capabilities of the system, Ni dot arrays and artificial cells have been fabricated with the photopolymer SU-8 and common lithographic techniques. The primary purpose of the Ni dot arrays was to determine the targeting accuracy of the beam in vacuum and in air. Additionally, this sample was employed to evaluate the system performance during cell target irradiation experiments. The Ni dot arrays were also used for beam characterization. The artificial cells were originally fabricated to test the software for cell recognition and localization, developed and implemented at the LNM. However, this sample became very functional to make small adjustments at the irradiation chamber for cell irradiation experiments. A description of the samples, fabrication procedure and applications are presented in this paper. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:2117 / 2121
页数:5
相关论文
共 50 条
  • [1] Development of the IFJ single ion hit facility for cell irradiation
    Veselov, O.
    Polak, W.
    Ugenskiene, R.
    Lebed, K.
    Lekki, J.
    Stachura, Z.
    Styczen, J.
    RADIATION PROTECTION DOSIMETRY, 2006, 122 (1-4) : 316 - 319
  • [2] Characterization of SU-8 for electrokinetic microfluidic applications
    Sikanen, T
    Tuomikoski, S
    Ketola, RA
    Kostiainen, R
    Franssila, S
    Kotiaho, T
    LAB ON A CHIP, 2005, 5 (08) : 888 - 896
  • [3] Glass/SU-8 microchip for electrokinetic applications
    Lima, Renato Sousa
    Gomes Carneiro Leao, Paulo Augusto
    Monteiro, Alessandra Maffei
    de Oliveira Piazzetta, Maria Helena
    Gobbi, Angelo Luiz
    Mazo, Luiz Henrique
    Carrilho, Emanuel
    ELECTROPHORESIS, 2013, 34 (20-21) : 2996 - 3002
  • [4] Innovative SU-8 Lithography Techniques and Their Applications
    Lee, Jeong Bong
    Choi, Kyung-Hak
    Yoo, Koangki
    MICROMACHINES, 2015, 6 (01) : 1 - 18
  • [5] Design of a single ion hit facility
    Cholewa, M
    Saint, A
    Legge, GJF
    Kamiya, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 130 (1-4): : 275 - 279
  • [6] Design of a single ion hit facility
    Cholewa, M.
    Saint, A.
    Legge, G.J.F.
    Kamiya, T.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1997, 130 (1-4): : 275 - 279
  • [7] Single-mode waveguides with SU-8 polymer core and cladding for MOEMS applications
    Nordstrom, Maria
    Zauner, Dan A.
    Boisen, Anja
    Hubner, Jorg
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2007, 25 (05) : 1284 - 1289
  • [8] Biocompatibility of SU-8 and Its Biomedical Device Applications
    Chen, Ziyu
    Lee, Jeong-Bong
    MICROMACHINES, 2021, 12 (07)
  • [9] Removal of SU-8 photoresist for thick film applications
    Dentinger, PM
    Clift, WM
    Goods, SH
    MICROELECTRONIC ENGINEERING, 2002, 61-2 : 993 - 1000
  • [10] Development of MWCNT/SU-8 nanofiber composite using Electrospinning Technique for Biosensing applications
    Prakash, Durga M.
    Krishna, Siva Rama, V
    Dutta, Asudeb
    Sharma, C. S.
    Singh, Shiv Govind
    2014 IEEE SENSORS, 2014, : 2093 - 2096