Normothermic Regional Perfusion and Hypothermic Oxygenated Machine Perfusion for Livers Donated After Controlled Circulatory Death With Prolonged Warm Ischemia Time: A Matched Comparison With Livers From Brain-Dead Donors

被引:23
|
作者
Patrono, Damiano [1 ]
Zanierato, Marinella [2 ]
Vergano, Marco [3 ]
Magaton, Chiara [1 ]
Diale, Enrico [1 ]
Rizza, Giorgia [1 ]
Catalano, Silvia [1 ]
Mirabella, Stefano [1 ]
Cocchis, Donatella [1 ]
Potenza, Raffaele [4 ]
Livigni, Sergio [3 ]
Balagna, Roberto [5 ]
Romagnoli, Renato [1 ]
机构
[1] Univ Turin, AOU Citta Salute & Sci Torino, Gen Surg 2U Liver Transplant Unit, Turin, Italy
[2] Azienda Osped Univ Citta Salute & Sci Torino, Dept Anesthesia & Crit Care, Turin, Italy
[3] San Giovanni Bosco Hosp, Dept Anesthesia & Intens Care, Turin, Italy
[4] Azienda Osped Univ Citta Salute & Sci Torino, Reg Procurement Org, Turin, Italy
[5] AOU Citta Salute & Sci Torino, Anesthesia Dept 2, Turin, Italy
关键词
donation after circulatory death; abdominal normothermic regional perfusion; hypothermic oxygenated machine perfusion; warm ischemia time; ischemic cholangiopathy; liver transplantation outcome; CARDIAC DEATH; POSTREPERFUSION SYNDROME; TRANSPLANTATION; CLASSIFICATION; CHOLANGIOPATHY; PROPOSAL; IMPACT; SCORE;
D O I
10.3389/ti.2022.10390
中图分类号
R61 [外科手术学];
学科分类号
摘要
Prolonged warm ischemia time (WIT) has a negative prognostic value in liver transplantation (LT) using grafts procured after circulatory death (DCD). To assess the value of abdominal normothermic regional perfusion (A-NRP) associated with dual hypothermic oxygenated machine perfusion (D-HOPE) in controlled DCD LT, prospectively collected data on LTs performed between January 2016 and July 2021 were analyzed. Outcome of controlled DCD LTs performed using A-NRP + D-HOPE (n = 20) were compared to those performed with grafts procured after brain death (DBD) (n = 40), selected using propensity-score matching. DCD utilization rate was 59.5%. In the DCD group, median functional WIT, A-NRP and D-HOPE time was 43, 246, and 205 min, respectively. Early outcomes of DCD grafts recipients were comparable to those of matched DBD LTs. In DCD and DBD group, incidence of anastomotic biliary complications and ischemic cholangiopathy was 15% versus 22% (p = 0.73) and 5% versus 2% (p = 1), respectively. One-year patient and graft survival was 100% versus 95% (p = 0.18) and 90% versus 95% (p = 0.82). In conclusion, the association of A-NRP + D-HOPE in DCD LT with prolonged WIT allows achieving comparable outcomes to DBD LT.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Outcome of livers from donation after circulatory death with prolonged warm ischemia time treated with normothermic regional perfusion and hypothermic oxygenated machine perfusion
    Patrono, D.
    Zanierato, M.
    Magaton, C.
    Rizza, G.
    Catalano, S.
    Mirabella, S.
    Potenza, R.
    Romagnoli, R.
    TRANSPLANTATION, 2022, 106 (8S) : 34 - 35
  • [2] Normothermic machine perfusion preservation on livers from donors after circulatory death
    Liu, Q.
    Ali, K.
    Cazzaniga, B.
    Del Prete, L.
    Tuul, M.
    Uso, T. Diago
    Fujiki, M.
    Aucejo, F.
    Eghtesad, B.
    D'Amico, G.
    Kwon, C. H. D.
    Chaudhry, S.
    Pita, A.
    Kim, J.
    Schlegel, A.
    Doi, J.
    Khalil, M.
    Fernandes, E.
    Kusakabe, J.
    Calderon, E.
    Miller, C.
    Hashimoto, K.
    Quintini, C.
    TRANSPLANTATION, 2023, 107 (09) : 193 - 193
  • [3] Hypothermic Oxygenated Machine Perfusion Prevents Arteriolonecrosis of the Peribiliary Plexus in Pig Livers Donated after Circulatory Death
    den Dries, Sanna op
    Sutton, Michael E.
    Karimian, Negin
    de Boer, Marieke T.
    Wiersema-Buist, Janneke
    Gouw, Annette S. H.
    Leuvenink, Henri G. D.
    Lisman, Ton
    Porte, Robert J.
    PLOS ONE, 2014, 9 (02):
  • [4] Appropriate timing for hypothermic machine perfusion to preserve livers donated after circulatory death
    Hu, Xiaoyan
    Wang, Wei
    Zeng, Cheng
    He, Weiyang
    Zhong, Zibiao
    Liu, Zhongzhong
    Wang, Yanfeng
    Ye, Qifa
    MOLECULAR MEDICINE REPORTS, 2020, 22 (03) : 2003 - 2011
  • [5] Viability assessment of livers donated after circulatory determination of death during normothermic regional perfusion
    Steinberg, Irene
    Patrono, Damiano
    De Cesaris, Enrico
    Luca, Michele
    Catalano, Giorgia
    Marro, Matteo
    Rizza, Giorgia
    Simonato, Erika
    Brazzi, Luca
    Romagnoli, Renato
    Zanierato, Marinella
    ARTIFICIAL ORGANS, 2023, 47 (10) : 1592 - 1603
  • [6] NORMOTHERMIC MACHINE PERFUSION OF LIVERS FROM DONORS AFTER CARDIAC DEATH
    Fondevila, C.
    Hessheimer, A. J.
    Maathuis, M. H. J.
    Calatayud, D.
    Sanchez, O.
    Taura, P.
    Sanchez-Cabus, S.
    van der Plaats, A.
    Fuster, J.
    Leuvenink, H.
    Rimola, A.
    Rakhorst, G.
    Ploeg, R.
    Garcia-Valdecasas, J. C.
    LIVER TRANSPLANTATION, 2008, 14 (07) : S120 - S120
  • [7] Normothermic machine perfusion of livers from donors after cardiac death
    Fondevila, Constantino
    Hessheimer, Amelia J.
    Maathuis, Mark-Hugo J.
    Calatayud, David
    Sanchez, Olga
    Taura, Pilar
    Sanchez, Santiago
    van der Plaats, Arjan
    Fuster, Jose
    Leuvenink, Henri G. D.
    Rimola, Antonio
    Rakhorst, Gerhard
    Ploeg, Rutger J.
    Garcia-Valdecasas, Juan C.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2008, 8 : 426 - 426
  • [8] Multicenter comparison of liver transplantation with uncontrolled versus controlled donors after circulatory death with prolonged warm ischemia using normothermic regional perfusion and exsitu machine perfusion
    Ghinolfi, D.
    Patrono, D.
    De Carlis, R.
    Melandro, F.
    Buscemi, V.
    Farnesi, F.
    Torri, F.
    Lauterio, A.
    Di Salvo, M.
    Cerchione, R.
    Zanierato, M.
    Morganti, R.
    De Simone, P.
    Romagnoli, R.
    De Carlis, L.
    TRANSPLANTATION, 2023, 107 (09) : 183 - 183
  • [9] Hypothermic Oxygenated Machine Perfusion of Liver Grafts from Brain-Dead Donors
    Patrono, Damiano
    Surra, Astrid
    Catalano, Giorgia
    Rizza, Giorgia
    Berchialla, Paola
    Martini, Silvia
    Tandoi, Francesco
    Lupo, Francesco
    Mirabella, Stefano
    Stratta, Chiara
    Salizzoni, Mauro
    Romagnoli, Renato
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [10] Hypothermic Oxygenated Machine Perfusion of Liver Grafts from Brain-Dead Donors
    Damiano Patrono
    Astrid Surra
    Giorgia Catalano
    Giorgia Rizza
    Paola Berchialla
    Silvia Martini
    Francesco Tandoi
    Francesco Lupo
    Stefano Mirabella
    Chiara Stratta
    Mauro Salizzoni
    Renato Romagnoli
    Scientific Reports, 9