Breakthrough analysis for filtering facepiece respirators impregnated with activated carbon

被引:7
|
作者
Clinger, Jayson C. [1 ]
O'Shaughnessy, Patrick T. [1 ]
机构
[1] Univ Iowa, Dept Occupat & Environm Hlth, Iowa City, IA USA
关键词
Breakthrough time; dust mask; semivolatile organic compounds; ADSORPTION; EXPOSURES; DRY;
D O I
10.1080/15459624.2019.1594838
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Several manufacturers are producing disposable dual-use dust masks that are primarily designed to protect against airborne particulate exposures but that also contain a layer of activated carbon to provide protection against organic vapors (OVs) at levels below permissible exposure levels, referred to as "nuisance level" by the FFR manufacturers. Industries identified in the literature as commonly having employees exposed to nuisance-level OVs include beautician salons, dry cleaning operations, and pesticide applications. This study investigated the adsorption capabilities of three different dual-use dust masks that contain both filter media to remove particles and activated carbon to capture OVs. The three dual-use dust masks were tested and compared relative to the 50% breakthrough time for two OVs (acetone and perchloroethylene) and one non-carbon-based contaminant gas (ammonia) often found in agricultural settings at nuisance-level amounts. The dual-use dust masks were exposed to 15 ppm and 50 ppm for all 3 compounds, which represented the range of nuisance-level exposure documented in literature. Most tests were conducted at 21 degrees C and 50% relative humidity. A relative humidity level of 95% was also created to compare results under that condition. The non-approved dual-use dust masks were ineffective for all vapors and offered less than 10 min of protection before 50% breakthrough occurred. All dual-use dust masks performed poorly when exposed to ammonia, with breakthrough time less than 7 min at 50 ppm and 10 min at 15 ppm. The approved dual-use dust mask had 50% breakthrough times, for example, of 121 min and 233 min for acetone at 15 ppm and 50 ppm, respectively. The less volatile perchloroethylene took over 400 min to achieve 50% breakthrough at 50 ppm. High relative humidity reduced breakthrough times by up to 70%. These results indicate high variability in performance among dual-use dust masks. Performance is also dependent on gas/vapor volatility and levels of water vapor. However, one model tested, the 3M model 8514, did show promise as an acceptable method for greatly reducing nuisance-level OV exposures.
引用
收藏
页码:423 / 431
页数:9
相关论文
共 50 条
  • [1] Understanding Filtering Facepiece Respirators
    Andrews, Angela S.
    Kiederer, Meghan
    Casey, Megan L.
    AMERICAN JOURNAL OF NURSING, 2022, 122 (02) : 21 - 23
  • [2] Adsorption Performance of Activated-Carbon-Loaded Nonwoven Filters Used in Filtering Facepiece Respirators
    Okrasa, Malgorzata
    Hitz, Joern
    Nowak, Aleksandra
    Brochocka, Agnieszka
    Thelen, Christoph
    Walczak, Zbigniew
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (11)
  • [3] Improving the fit of filtering facepiece respirators
    Shah, Kamini
    Serban, Stefan
    Douglas, Gail V. A.
    BRITISH DENTAL JOURNAL, 2022,
  • [4] Pilot Study of Aromatic Hydrocarbon Adsorption Characteristics of Disposable Filtering Facepiece Respirators that Contain Activated Carbon
    Rozzi, Tony
    Snyder, Jay
    Novak, Debra
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2012, 9 (11) : 624 - 629
  • [5] Analysis of Residual Chemicals on Filtering Facepiece Respirators After Decontamination
    Salter, W. B.
    Kinney, K.
    Wallace, W. H.
    Lumley, A. E.
    Heimbuch, B. K.
    Wander, J. D.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2010, 7 (08) : 437 - 445
  • [6] FIBER RELEASE FROM FILTERING FACEPIECE RESPIRATORS
    HOWIE, RM
    ADDISON, J
    CHERRIE, J
    ROBERTSON, A
    DODGSON, J
    ANNALS OF OCCUPATIONAL HYGIENE, 1986, 30 (01): : 131 - 133
  • [7] Decontamination Methods for Reuse of Filtering Facepiece Respirators
    Su-Velez, Brooke M.
    Maxim, Tom
    Long, Jennifer L.
    St John, Maie A.
    Holliday, Michael A.
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2020, 146 (08) : 734 - 740
  • [8] Application of Olfactometry to Assess the Anti-Odor Properties of Filtering Facepiece Respirators Containing Activated Carbon Nonwovens
    Okrasa, Malgorzata
    Szulc, Justyna
    Brochocka, Agnieszka
    Gutarowska, Beata
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (15)
  • [9] Limited Reuse and Extended Use of Filtering Facepiece Respirators
    Company Sancho, Maria Consuelo
    Gonzalez-Maria, Esther
    Abad-Corpa, Eva
    ENFERMERIA CLINICA, 2021, 31 : S78 - S83
  • [10] A critical review of methods for decontaminating filtering facepiece respirators
    Jacobs, Neva
    Chan, Kathy
    Leso, Veruscka
    D'Anna, Andrea
    Hollins, Dana
    Iavicoli, Ivo
    TOXICOLOGY AND INDUSTRIAL HEALTH, 2020, 36 (09) : 654 - 680