Are Aneurysms Treated With Balloon-Assisted Coiling and Stent-Assisted Coiling Different? Morphological Analysis of 113 Unruptured Wide-Necked Aneurysms Treated With Adjunctive Devices

被引:17
|
作者
Peterson, Eric [1 ]
Hanak, Brian [2 ]
Morton, Ryan [2 ]
Osbun, Joshua W. [2 ]
Levitt, Michael R. [2 ]
Kim, Louis J. [2 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Neurol Surg, Miami, FL 33136 USA
[2] Univ Washington, Harborview Med Ctr, Sch Med, Dept Neurol Surg, Seattle, WA 98104 USA
关键词
Balloon assistance; Endovascular; Morphological analysis; Stent assistance; Unruptured aneurysm; INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT; PIPELINE EMBOLIZATION; CEREBRAL ANEURYSMS; NEUROFORM STENT; COMPLICATIONS; ANGIOGRAPHY; OUTCOMES; SAFETY;
D O I
10.1227/NEU.0000000000000366
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: In the endovascular treatment of wide-necked unruptured aneurysms, there is controversy over which adjunctive device (stent vs balloon) is appropriate. At the payer level it has been posited that stents and balloons treat the same aneurysms, and, as such, the more expensive stents should not be reimbursed. OBJECTIVE: We challenge this assertion, and instead hypothesize that aneurysms treated with stent assistance are morphologically different than those selected for balloon assistance. METHODS: Retrospective review of unruptured aneurysms treated with an adjunctive device between 2008 and 2010. Morphological analysis was performed on the pretreatment 2-D catheter angiogram. The immediate posttreatment Raymond score was compared with that seen on the 12-month follow-up angiogram. RESULTS: One hundred six unruptured aneurysms were treated with an adjunctive device and followed for a mean of 24.5 months. Morphological analysis revealed a lower dome-to-neck ratio (1.5 vs 1.2) and aspect ratio (1.44 vs 1.16) in the aneurysms treated with stent assistance vs balloon assistance. Of the 15.3% that were worse on follow-up angiography, there was no statistical difference between those treated with a stent vs a balloon (17.1% vs 14.2%). The overall re-treatment rate was 10.2% and was not statistically different between the 2 groups (12.7% vs 5.7%). CONCLUSION: We found that unruptured aneurysms selected for treatment with stent-assisted coiling are morphologically different from those selected for treatment with balloon assistance. Despite the more challenging morphology, Raymond scores and re-treatment rates at 1 year were not statistically different between the 2 groups, suggesting an important role for stents in the treatment of unruptured aneurysms.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 50 条
  • [1] Comparison of Stent-Assisted Coiling and Balloon-Assisted Coiling in the Treatment of Ruptured Wide-Necked Intracranial Aneurysms in the Acute Period
    Cai, Kefu
    Zhang, Yunfeng
    Shen, Lihua
    Ni, Yaohui
    Ji, Qiuhong
    [J]. WORLD NEUROSURGERY, 2016, 96 : 316 - 321
  • [2] Stent-Assisted Coiling Versus Balloon-Assisted Coiling for the Treatment of Ruptured Wide-Necked Aneurysms: A 2-Center Experience
    Vivanco-Suarez, Juan
    Wallace, Adam N.
    Dandapat, Sudeepta
    Lopez, Gloria V.
    Mendez-Ruiz, Aldo
    Kayan, Yasha
    Copelan, Alexander Z.
    Dajles, Andres
    Zevallos, Cynthia B.
    Quispe-Orozco, Darko
    Mendez-Ruiz, Alan
    Galecio-Castillo, Milagros
    Samaniego, Edgar A.
    Farooqui, Mudassir
    Delgado, Josser E.
    Ortega-Gutierrez, Santiago
    [J]. STROKE-VASCULAR AND INTERVENTIONAL NEUROLOGY, 2023, 3 (01):
  • [3] Stent-Assisted Coiling of Ruptured Wide-Necked Intracranial Aneurysms
    Li, Conghui
    Li, Youxiang
    [J]. INTERVENTIONAL NEURORADIOLOGY, 2013, 19 (03) : 283 - 288
  • [4] Assisted coiling of saccular wide-necked unruptured intracranial aneurysms: stent versus balloon
    Consoli, Arturo
    Vignoli, Chiara
    Renieri, Leonardo
    Rosi, Andrea
    Chiarotti, Ivano
    Nappini, Sergio
    Limbucci, Nicola
    Mangiafico, Salvatore
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (01) : 52 - 57
  • [5] Stent-assisted coiling embolization of tiny, wide-necked intracranial aneurysms
    Zheng, Yongtao
    Song, Yanbing
    Liu, Dajun
    Liu, Yingjun
    Xu, Qiang
    Tian, Yanlong
    Leng, Bing
    [J]. ACTA NEUROCHIRURGICA, 2017, 159 (01) : 93 - 100
  • [6] Stent-assisted coiling embolization of tiny, wide-necked intracranial aneurysms
    Yongtao Zheng
    Yanbing Song
    Dajun Liu
    Yingjun Liu
    Qiang Xu
    Yanlong Tian
    Bing Leng
    [J]. Acta Neurochirurgica, 2017, 159 : 93 - 100
  • [7] Progressive Occlusion of Aneurysms in Stent-assisted Coiling of Ruptured Wide-necked Intracranial Aneurysms
    Wu, Jing
    Peng, Tangming
    Liu, Aihua
    Qian, Zenghui
    Kang, Huibin
    Li, Youxiang
    Wu, Zhongxue
    [J]. JOURNAL OF NEUROLOGICAL SCIENCES-TURKISH, 2014, 31 (04): : 752 - 760
  • [8] Outcomes of Stent-Assisted Coiling Using the Neuroform Atlas Stent in Unruptured Wide-Necked Intracranial Aneurysms
    Kwon, Ohyuk
    Chung, Joonho
    [J]. JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2021, 64 (01) : 23 - 29
  • [9] Stent-assisted coiling of wide-necked intracranial aneurysms using the Solitaire AB stent
    Huded, Vikram
    Nair, Rithesh R.
    Vyas, Devashish D.
    Chauhan, Bhumir N.
    [J]. JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2014, 5 (03) : 254 - 257
  • [10] Neuroform atlas stent-assisted coiling of tiny wide-necked intracranial aneurysms
    Dong, Linggen
    Chen, Xiheng
    Wang, Jiejun
    Zhang, Longhui
    Zhao, Zhiqiang
    Peng, Qichen
    Liu, Peng
    Lv, Ming
    [J]. FRONTIERS IN NEUROLOGY, 2022, 13