Multi-task autoencoder based classification-regression model for patient-specific VMAT QA

被引:29
|
作者
Wang, Le [1 ,2 ,4 ]
Li, Jiaqi [3 ,5 ]
Zhang, Shuming [3 ]
Zhang, Xile [3 ]
Zhang, Qilin [3 ]
Chan, Maria F. [6 ]
Yang, Ruijie [3 ]
Sui, Jing [1 ,2 ,4 ]
机构
[1] Chinese Acad Sci, Brainnetome Ctr, Beijing, Peoples R China
[2] Chinese Acad Sci, Inst Automat, Natl Lab Pattern Recognit, Beijing, Peoples R China
[3] Peking Univ Third Hosp, Dept Radiat Oncol, Beijing, Peoples R China
[4] Chinese Acad Sci, Univ Chinese Acad Sci, CAS Ctr Excellence Brain Sci & Intelligence Techn, Inst Automat, Beijing, Peoples R China
[5] Capital Med Univ, Beijing Childrens Hosp, Beijing, Peoples R China
[6] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 23期
基金
中国国家自然科学基金;
关键词
VMAT QA; patient-specific QA; deep learning; radiotherapy; QUALITY-ASSURANCE; RADIOMIC ANALYSIS; IMRT; MODULATION; COMPLEXITY; RADIOTHERAPY; RAPIDARC; BEAMS;
D O I
10.1088/1361-6560/abb31c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Patient-specific quality assurance (PSQA) of volumetric modulated arc therapy (VMAT) to assure accurate treatment delivery is resource-intensive and time-consuming. Recently, machine learning has been increasingly investigated in PSQA results prediction. However, the classification performance of models at different criteria needs further improvement and clinical validation (CV), especially for predicting plans with low gamma passing rates (GPRs). In this study, we developed and validated a novel multi-task model called autoencoder based classification-regression (ACLR) for VMAT PSQA. The classification and regression were integrated into one model, both parts were trained alternatively while minimizing a defined loss function. The classification was used as an intermediate result to improve the regression accuracy. Different tasks of GPRs prediction and classification based on different criteria were trained simultaneously. Balanced sampling techniques were used to improve the prediction accuracy and classification sensitivity for the unbalanced VMAT plans. Fifty-four metrics were selected as inputs to describe the plan modulation-complexity and delivery-characteristics, while the outputs were PSQA GPRs. A total of 426 clinically delivered VMAT plans were used for technical validation (TV), and another 150 VMAT plans were used for CV to evaluate the generalization performance of the model. The ACLR performance was compared with the Poisson Lasso (PL) model and found significant improvement in prediction accuracy. In TV, the absolute prediction error (APE) of ACLR was 1.76%, 2.60%, and 4.66% at 3%/3 mm, 3%/2 mm, and 2%/2 mm, respectively; whereas the APE of PL was 2.10%, 3.04%, and 5.29% at 3%/3 mm, 3%/2 mm, and 2%/2 mm, respectively. No significant difference was found between CV and TV in prediction accuracy. ACLR model set with 3%/3 mm can achieve 100% sensitivity and 83% specificity. The ACLR model could classify the unbalanced VMAT QA results accurately, and it can be readily applied in clinical practice for virtual VMAT QA.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Commissioning and clinical implementation of an Autoencoder based Classification-Regression model for VMAT patient-specific QA in a multi-institution scenario
    Yang, Ruijie
    Yang, Xueying
    Wang, Le
    Li, Dingjie
    Guo, Yuexin
    Li, Ying
    Guan, Yumin
    Wu, Xiangyang
    Xu, Shouping
    Zhang, Shuming
    Chan, Maria F.
    Geng, Lisheng
    Sui, Jing
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : 230 - 240
  • [2] Commissioning and clinical implementation of an Autoencoder based Classification-Regression model for VMAT patientspecific QA in a multi-institution scenario (vol 161, pg 230, 2021)
    Yang, Ruijie
    Yang, Xueying
    Wang, Le
    Li, Dingjie
    Guo, Yuexin
    Li, Ying
    Guan, Yumin
    Wu, Xiangyang
    Xu, Shouping
    Zhang, Shuming
    Chan, Maria F.
    Geng, Lisheng
    Sui, Jing
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 163 : 119 - 119
  • [3] Complexity metric as a complement to measurement based IMRT/VMAT patient-specific QA
    Gotstedt, J.
    Hauer, A. Karlsson
    Back, A.
    [J]. 8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [4] AAPM Task Group Report 307: Use of EPIDs for Patient-Specific IMRT and VMAT QA
    Dogan, Nesrin
    Mijnheer, Ben J.
    Padgett, Kyle
    Nalichowski, Adrian
    Wu, Chuan
    Nyflot, Matthew J.
    Olch, Arthur J.
    Papanikolaou, Niko
    Shi, Jie
    Holmes, Shannon M.
    Moran, Jean
    Greer, Peter B.
    [J]. Medical Physics, 2023, 50 (08)
  • [5] Clinical Implementation of Deep Learning-Based VMAT Patient-Specific QA
    Yang, X.
    Wang, L.
    Li, D.
    Guo, Y.
    Li, Y.
    Guan, Y.
    Wu, X.
    Xu, S.
    Zhang, S.
    Chan, M.
    Yang, R.
    Geng, L.
    Sui, J.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [6] Comparison of Two Different Setups for VMAT Patient-Specific QA
    Clemente, F.
    Perez-Vara, C.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [7] EXPERIENCE OF PATIENT-SPECIFIC QA FOR VMAT WITH DIFFERENT INSTRUMENTS.
    Declich, F.
    Bonsignore, F.
    Butti, I.
    Frigerio, C.
    Sangalli, G.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S511 - S511
  • [8] Optical Tracking Guided Patient-Specific VMAT QA with ArcCHECK
    Fan, Q.
    Park, C.
    Lu, B.
    Barraclough, B.
    Lebron, S.
    Li, J.
    Liu, C.
    Yan, G.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3470 - 3470
  • [9] VMAT Commissioning and Patient-Specific QA Using MatriXX Phantom
    Bao, A.
    Geis, P.
    Zheng, Y.
    Pereira, G.
    Petchler, N. Kuc
    Elconin, J.
    Machtay, M.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E273 - E274
  • [10] Patient-Specific EPID Based High Resolution 3D VMAT QA
    Nicol, S.
    Furstoss, C.
    Munger, P.
    Wierzbicki, W.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)