Enhancement of UV disinfection efficiency by arraying inclined lamps

被引:4
|
作者
Lim, Seung-Joo
Lee, Yoon-Jin [1 ]
机构
[1] Cheongju Univ, Dept Environm Engn, Chungbuk 360764, South Korea
[2] Shingang Hi Tech Co Inc, Ecol & Environm Res Inst, Chungnam 330720, South Korea
关键词
UV disinfection; inclined lamp; UV dose; slope; diameter of the UV lamp; velocity;
D O I
10.1007/BF02706800
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A computational study on UV disinfection efficiency has been developed based on the Lambert-Beer law. Comparing a UV lamp arranged vertically to the flow of one arranged on an incline led to the conclusion that UV doses could be increased. The study of the inclination effect was divided into four stages in order to evaluate the increase in the UV dose at each stage. The slope of the inclined UV lamp ranged between 1 degrees and 89 degrees (0 degrees <theta < 90 degrees) with other parameters such as diameter of the UV lamp, distance from the surface of the UV lamp, and velocity also recorded. The increase of UV dosage was largely affected by the diameter and velocity of the UV lamp, especially on a lesser slope. To obtain a greater UV dose, it was necessary to assemble UV lamps with lesser slopes. By arranging lamps on an incline, UV disinfection could be enhanced.
引用
收藏
页码:595 / 600
页数:6
相关论文
共 50 条
  • [1] Enhancement of UV disinfection efficiency by arraying inclined lamps
    Seung-Joo Lim
    Yoon-Jin Lee
    Korean Journal of Chemical Engineering, 2006, 23 : 595 - 600
  • [2] The wastewater disinfection system of UV lamps based on can bus
    Wang, Song
    Liu, Mingguang
    Hao, Shengyu
    Li, Na
    2007 International Symposium on Computer Science & Technology, Proceedings, 2007, : 548 - 551
  • [3] What means "dose" in UV-disinfection with medium pressure lamps?
    Cabaj, A
    Sommer, R
    Pribil, W
    Haider, T
    OZONE-SCIENCE & ENGINEERING, 2001, 23 (03) : 239 - 244
  • [4] Characterization of permanent fouling on the surfaces of UV lamps used for wastewater disinfection
    Peng, J
    Qiu, Y
    Gehr, R
    WATER ENVIRONMENT RESEARCH, 2005, 77 (04) : 309 - +
  • [5] Laboratory investigation of inorganic fouling of low pressure UV disinfection lamps
    Sheriff, M
    Gehr, R
    WATER QUALITY RESEARCH JOURNAL OF CANADA, 2001, 36 (01): : 71 - 92
  • [6] Disinfection with flash lamps
    Wekhof, A
    PDA JOURNAL OF PHARMACEUTICAL SCIENCE AND TECHNOLOGY, 2000, 54 (03): : 264 - 276
  • [7] Enhancement of UV disinfection of urine matrixes by electrochemical oxidation
    Herraiz-Carbone, Miguel
    Cotillas, Salvador
    Lacasa, Engracia
    Pablo, Canizares
    Rodrigo, Manuel A.
    Saez, Cristina
    JOURNAL OF HAZARDOUS MATERIALS, 2021, 410
  • [8] Prediction of the effects of vortex shedding on UV disinfection efficiency
    Younis, B. A.
    Yang, T. H.
    JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2011, 60 (03): : 147 - 158
  • [9] Surface Disinfection Systems with UV-C Lamps - Verification Measurements and Design Procedure Proposal
    Wisniewski, Andrzej
    Skarzynski, Krzysztof
    Pracki, Piotr
    Krupinski, Rafal
    Wolska, Agnieszka
    Wiselka, Mariusz
    Pawlak, Andrzej
    LEUKOS, 2025, 21 (02) : 125 - 140
  • [10] EVALUATION OF THE EFFICIENCY OF A UV PLANT FOR DRINKING-WATER DISINFECTION
    SOMMER, R
    CABAJ, A
    WATER SCIENCE AND TECHNOLOGY, 1993, 27 (3-4) : 357 - 362