Effect of sensing system on the incidence of myopotential oversensing during bradycardia pacing in implantable cardioverter-defibrillators

被引:12
|
作者
Mann, DE [1 ]
Otto, L [1 ]
Kelly, PA [1 ]
Reiter, MJ [1 ]
机构
[1] Univ Colorado, Hlth Sci Ctr, Div Cardiol, Dept Med, Denver, CO 80262 USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2000年 / 85卷 / 11期
关键词
D O I
10.1016/S0002-9149(00)00776-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compared the incidence of oversensing of myopotentials during bradycardia pacing in implantable cardioverter-defibrillators from 3 different manufacturers, with 3 different types of sensing systems. The Ventritex sensing system, which uses maximum gain continuously during bradycardia pacing, had a higher incidence of oversensing (24% of patients) than the sensing systems of CPI (3%) or Medtronic (0%), suggesting that the Ventritex sensing system may be unsuitable for use in a dual-chamber defibrillator.
引用
收藏
页码:1380 / +
页数:4
相关论文
共 50 条
  • [1] Management of diaphragmatic myopotential oversensing in implantable cardioverter defibrillators
    Day, J
    Lauer, M
    Young, C
    Han, J
    Goold, P
    Chun, S
    Liem, LB
    EUROPACE 2001, 2001, : 583 - 588
  • [2] Incidence of oversensing resulting in inappropriate shocks in transvenous implantable cardioverter-defibrillators
    Cho, YK
    Corsello, A
    Robotis, D
    Okreglicki, A
    Rosero, SZ
    Daubert, JP
    Huang, DT
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 89A - 89A
  • [3] T-Wave Oversensing with Contemporary Implantable Cardioverter-Defibrillators
    Strik, Marc
    Ploux, Sylvain
    Eschalier, Romain
    Mondoly, Pierre
    Fontagne, Leslie
    Ramirez, F. Daniel
    Haissaguerre, Michel
    Bordachar, Pierre
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (10)
  • [4] High incidence of diaphragmatic myopotential oversensing by a specific implantable cardioverter defibrillator
    Baldinger, Samuel H.
    Haeberlin, Andreas
    Servatius, Helge
    Seiler, Jens
    Noti, Fabian
    Lam, Anna
    Sweda, Romy
    Reichlin, Tobias
    Tanner, Hildegard
    Roten, Laurent
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (02): : 234 - 239
  • [5] Clinical impact of ECG changes on oversensing of subcutaneous implantable cardioverter-defibrillators
    Hakamata, Takahiro
    Otsuki, Sou
    Izumi, Daisuke
    Sakaguchi, Yuta
    Suzuki, Naomasa
    Ikami, Yasuhiro
    Hasegawa, Yuki
    Yagihara, Nobue
    Iijima, Kenichi
    Chinushi, Masaomi
    Fuse, Koichi
    Inomata, Takayuki
    HEART RHYTHM, 2022, 19 (10) : 1704 - 1711
  • [6] Single vs. dual chamber implantable cardioverter-defibrillators or programming of implantable cardioverter-defibrillators in patients without a bradycardia pacing indication: systematic review and meta-analysis
    Zeitler, Emily P.
    Sanders, Gillian D.
    Singh, Kavisha
    Greenfield, Ruth Ann
    Gillis, Anne M.
    Wilkoff, Bruce L.
    Piccini, Jonathan P.
    Al-Khatib, Sana M.
    EUROPACE, 2018, 20 (10): : 1621 - 1629
  • [7] Causes of ventricular oversensing in implantable cardioverter-defibrillators: Implications for diagnosis of lead fracture
    Gunderson, Bruce D.
    Swerdlow, Charles D.
    Wilcox, Jay M.
    Hayman, Jean E.
    Ousdigian, Kevin T.
    Ellenbogen, Kenneth A.
    HEART RHYTHM, 2010, 7 (05) : 626 - 633
  • [8] Comparison of oversensing during bradycardia pacing in two types of implantable cardioverter-defibrillator systems
    Mann, DE
    Damle, RS
    Kelly, PA
    Landers, M
    Otto, L
    Reiter, MJ
    AMERICAN HEART JOURNAL, 1998, 136 (04) : 658 - 663
  • [9] Efficacy of antitachycardia pacing in hypertrophic cardiomyopathy with implantable cardioverter-defibrillators
    Lee, C. H.
    Kim, S.
    Choi, H. O.
    Kim, K. H.
    Nam, G.
    Choi, K.
    Kim, Y.
    EUROPEAN HEART JOURNAL, 2011, 32 : 921 - 921
  • [10] Multiple attempts of antitachycardia pacing are useful in implantable cardioverter-defibrillators
    Schaumann, A
    Poppinga, A
    Neufert, C
    Fabian, O
    Herse, B
    Unterberg, C
    Kreuzer, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 434A - 434A