Determination of Trace Lead and Cadmium in Water Samples by Anodic Stripping Voltammetry with a NafionIonic Liquid-Coated Bismuth Film Electrode

被引:15
|
作者
Yang, Die [1 ]
Wang, Liang [1 ]
Chen, Zuliang [1 ]
Megharaj, Mallavarapu [1 ,2 ]
Naidu, Ravi [1 ,2 ]
机构
[1] Univ S Australia, Ctr Environm Risk Assessment & Remediat, Mawson Lakes, SA 5095, Australia
[2] CRC Contaminat Assessment & Remediat Environm, Mawson Lakes, SA 5095, Australia
关键词
Ionic liquid; Nafion; Glassy carbon electrode; Voltammetry; CARBON-PASTE ELECTRODE; MERCURY-BASED ELECTRODES; IONIC LIQUID; HEAVY-METALS; SILVER ELECTRODE; ELECTROANALYSIS; POTENTIALITIES; COPPER;
D O I
10.1002/elan.201300622
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new chemically modified bismuth film electrode coated with an ionic liquid [(1-ethyl-3-methylimidazolium tetracyanoborate (EMIM TCB)] and Nafion was developed for the simultaneous determination Pb2+ and Cd2+ by anodic stripping voltammetry. Compared with conventional bismuth film electrodes, this electrode exhibited greatly improved electrochemical activity for Pb2+ and Cd2+ detection due to the unique properties of Nafion polymer and ionic liquid. The key experimental parameters related to the fabrication of the electrode and the voltammetric measurements were optimized on the basis of the stripping signals, where the peak currents increased linearly with the metal concentrations in a range of 10-120 mu gL(-1) with a detect limit of 0.2 mu gL(-1) for Pb2+, and 0.5 mu gL(-1) for Cd2+ for 120s deposition. High reproducibility was indicated from the relative standard deviations (1.9 and 2.5%) for nine repetitive measurements of 20 mu gL(-1) Pb2+ and Cd2+, respectively. In addition, the surface characteristics of the modified BiFE were investigated by scanning electron microscopy (SEM), and results showed that fibril-like bismuth nanostructures were formed on the porous Nafion polymer matrix. Finally, the developed electrode was applied to determine Pb2+ and Cd2+ in water samples, indicating that this electrode was sensitive, reliable and effective for the simultaneous determination of Pb2+ and Cd2+.
引用
收藏
页码:639 / 647
页数:9
相关论文
共 50 条
  • [1] Determination of Lead in Ambient Aerosol Samples by Anodic Stripping Voltammetry on a Bismuth Film Electrode
    Palomo Marin, Ma Rosario
    Pinilla Gil, Eduardo
    Calvo Blazquez, Lorenzo
    [J]. ELECTROANALYSIS, 2011, 23 (01) : 215 - 221
  • [2] Nafion-coated bismuth film electrodes for the determination of trace lead and cadmium in herbal medicines by anodic stripping voltammetry
    Xu He
    Zeng Li-Ping
    Xing Su-Jie
    Xian Yue-Zhong
    Jin Li-Tong
    [J]. CHINESE JOURNAL OF CHEMISTRY, 2008, 26 (05) : 847 - 853
  • [3] Simultaneous Determination of Lead and Cadmium in the Presence of Morin by Adsorptive Stripping Voltammetry with a Nafion-Ionic Liquid-coated Mercury Film Electrode
    Nagles, Edgar
    Arancibia, Veronica
    Rios, Roxana
    Rojas, Carlos
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (06): : 5521 - 5533
  • [4] Application of a Lead Film Electrode in Adsorptive Stripping Voltammetry for the Determination of Indium Trace in Water Samples
    Grabarczyk, Malgorzata
    Wasag, Joanna
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (06) : H465 - H468
  • [5] Determination of cadmium by stripping voltammetry at a lead film electrode
    Korolczuk, Mieczyslaw
    Stepniowska, Anna
    Tyszczuk, Katarzyna
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2009, 89 (8-12) : 727 - 734
  • [6] Bismuth-Coated Iridium Microwire Electrode for the Determination of Trace Metals by Anodic Stripping Voltammetry
    Kyrisoglou, Christos
    Economou, Anastasios
    Efstathiou, Constantinos E.
    [J]. ELECTROANALYSIS, 2012, 24 (09) : 1825 - 1832
  • [7] Determination of Lead and Cadmium in Sea- and Freshwater by Anodic Stripping Voltammetry with a Vibrating Bismuth Electrode
    Bi, Zhaoshun
    Chapman, Conrad S.
    Salauen, Pascal
    van den Berg, Constant M. G.
    [J]. ELECTROANALYSIS, 2010, 22 (24) : 2897 - 2907
  • [8] Individual and simultaneous determination of lead, cadmium, and zinc by anodic stripping voltammetry at a bismuth bulk electrode
    Armstrong, Kristie C.
    Tatum, Clarissa E.
    Dansby-Sparks, Royce N.
    Chambers, James Q.
    Xue, Zi-Ling
    [J]. TALANTA, 2010, 82 (02) : 675 - 680
  • [9] Bismuth Film Electrodes for Indirect Determination of Sulfide Ion in Water Samples at Trace Level by Anodic Stripping Voltammetry
    Huang, De-Qian
    Xu, Bo-Lei
    Tang, Jie
    Yang, Li-Li
    Yang, Zheng-Biao
    Bi, Shu-Ping
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (04): : 2860 - 2873
  • [10] Multicommutated Anodic Stripping Voltammetry at Tubular Bismuth Film Electrode for Lead Determination in Gunshot Residues
    Rodriguez, Jose A.
    Ibarra, Israel S.
    Galan-Vidal, Carlos A.
    Vega, Marisol
    Barrado, Enrique
    [J]. ELECTROANALYSIS, 2009, 21 (3-5) : 452 - 458