Artificial Pancreas System With Unannounced Meals Based on a Disturbance Observer and Feedforward Compensation

被引:27
|
作者
Sanz, Ricardo [1 ]
Garcia, Pedro [1 ]
Diez, Jose-Luis [1 ,2 ]
Bondia, Jorge [1 ,2 ]
机构
[1] Univ Politecn Valencia, Inst Univ Automat & Informat Ind, Valencia 46022, Spain
[2] Ctr Invest Biomed Red Diabet & Enfermedades Metab, Madrid 28029, Spain
关键词
Insulin; Sugar; Adaptation models; Mathematical model; Feedforward systems; Diabetes; Pancreas; Artificial pancreas (AP); disturbance observer (DOB); feedforward compensation; type; 1; diabetes; MODEL-PREDICTIVE CONTROL; LOOP INSULIN DELIVERY; GLUCOSE CONTROL; HOME-USE; FEEDBACK; FEASIBILITY; MULTICENTER; CONTROLLER; SAFETY; ADULTS;
D O I
10.1109/TCST.2020.2975147
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This brief is focused on the closed-loop control of postprandial glucose levels of patients with type 1 diabetes mellitus after unannounced meals, which is still a major challenge toward a fully autonomous artificial pancreas. The main limitations are the delays introduced by the subcutaneous insulin pharmacokinetics and the glucose sensor, which typically leads to insulin overdelivery. Current solutions reported in the literature typically resort to meal announcement, which requires patient intervention. In this brief, a disturbance observer (DOB) is used to estimate the effect of unannounced meals, and the insulin pharmacokinetics is taken into account by means of a feedforward compensator. The proposed strategy is validated in silico with the UVa/Padova metabolic simulator. It is demonstrated how the DOB successfully estimates and counteracts not only the effect of meals but also the sudden drops in the glucose levels that may lead to hypoglycemia. For unannounced meals, results show a median time-in-range of 80% in a 30-day scenario with high carbohydrate content and large intrasubject variability. Optionally, users may decide to announce meals. In this case, considering severe bolus mismatch due to carbohydrate counting errors, the median time-in-range is increased up to 88%. In every case, hypoglycemia is avoided.
引用
收藏
页码:454 / 460
页数:7
相关论文
共 50 条
  • [1] Automatic Detection and Estimation of Unannounced Meals for Multivariable Artificial Pancreas System
    Samadi, Sediqeh
    Rashid, Mudassir
    Turksoy, Kamuran
    Feng, Jianyuan
    Hajizadeh, Iman
    Hobbs, Nicole
    Lazaro, Caterina
    Sevil, Mert
    Littlejohn, Elizabeth
    Cinar, Ali
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (03) : 235 - 246
  • [2] CLINICAL TRIAL OF AN ARTIFICIAL PANCREAS WITH LARGE UNANNOUNCED MEALS
    Cameron, F.
    Niemeyer, G.
    Wilson, D.
    Benasi, K.
    Clinton, P.
    Bequette, B. W.
    Buckingham, B.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A24 - A25
  • [3] Real-time insulin bolusing for unannounced meals with artificial pancreas
    Turksoy, Kamuran
    Hajizadeh, Iman
    Samadi, Sediqeh
    Feng, Jianyuan
    Sevil, Mert
    Park, Minsun
    Quinn, Laurie
    Littlejohn, Elizabeth
    Cinar, Ali
    CONTROL ENGINEERING PRACTICE, 2017, 59 : 159 - 164
  • [4] Unannounced Meals in the Artificial Pancreas: Detection Using Continuous Glucose Monitoring
    Ramkissoon, Charrise M.
    Herrero, Pau
    Bondia, Jorge
    Vehi, Josep
    SENSORS, 2018, 18 (03):
  • [5] SIMULATED TRIAL OF AN ARTIFICIAL PANCREAS USING ACCELEROMETERS AGAINST LARGE UNANNOUNCED MEALS
    Cameron, F.
    Baysal, N.
    Maahs, D.
    Buckingham, B.
    Bequette, B.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 : A21 - A21
  • [6] OUTPATIENT USE OF INTEROPERABLE ARTIFICIAL PANCREAS SYSTEM WITH LARGE MEALS AND UNANNOUNCED PHYSICAL ACTIVITIES IS SAFE IN ADOLESCENTS AND CHILDREN
    Deshpande, S.
    Weinzimer, S.
    Gibbons, K.
    Nally, L.
    Weyman, K.
    Carria, L.
    Zgorski, M.
    Doyle, F., III
    Dassau, E.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : A24 - A25
  • [7] Inpatient Trial of an Artificial Pancreas Based on Multiple Model Probabilistic Predictive Control with Repeated Large Unannounced Meals
    Cameron, Fraser
    Niemeyer, Guenter
    Wilson, Darrell M.
    Bequette, B. Wayne
    Benassi, Kari S.
    Clinton, Paula
    Buckingham, Bruce A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 (11) : 728 - 734
  • [8] DETECTION OF UNANNOUNCED MEALS IN ARTIFICIAL PANCREAS SYSTEMS USING ISOLATION FOREST ALGORITHM AND SURVIVAL ANALYSIS TECHNIQUES
    Idi, E.
    Pavan, J.
    Vettoretti, M.
    Facchinetti, A.
    Sparacino, G.
    Del Favero, S.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A118 - A119
  • [9] Flatness-based tracking of an electromechanical variable valve timing actuator with disturbance observer feedforward compensation
    Chladny, Ryan R.
    Koch, Charles R.
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2008, 16 (04) : 652 - 663
  • [10] THE IMPORTANCE OF MEAL MACRONUTRIENT CONTENT IN ARTIFICIAL PANCREAS USE WITH UNANNOUNCED (NO MEAL BOLUS) HIGH CARBOHYDRATE MEALS
    Pinsker, J.
    Feinberg, J.
    Lee, J. B.
    Michelson, A.
    Doyle, F. J., III
    Dassau, E.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 : A79 - A79